installation
30 | Grandview
®
G800C-1 Gas Fireplace
Clean Front Installation - Framing (Non Cool Wall)
Framing Dimensions
Description
Non Cool Wall
M
Framing Width
37-1/2"(953 mm)
N*
Framing Height
43" (1092 mm)
O
Framing Depth
19-1/4" (489 mm)
P (Top Vent Only)
Corner Facing Wall Width
46-1/2" (1181 mm)
Q (Top Vent Only)
Corner Facing Wall Width
65-3/4" (1670 mm)
R
Framed Chase Ceiling
62" (1575 mm)
S (Rear Vent)
Vent Centerline Height - Rear
29" (673 mm)
S 1 (Top Vent)
Vent Centerline Height - Top
44" (1118 mm)
T
Gas Connection Height
1-1/2" (38 mm)
U
Gas Connection Inset
6-3/8" (162 mm)
V
Gas Connection Width
3" (76 mm)
W
Clearance to Corner of Unit
2-3/4" (70 mm)
Non-combustible Height
11-1/2" (292 mm)
* Important: Framing height requires consideration of the hearth height. Dimension N = N + the thickness of the installed hearth.
S
S
U
T
V
Q
P
M
N
O
Combustible header
R
Top Vent
Rear Vent
W
Corner=Top Vent Only
IMPORTANT: Corner applications are vented from the top
only - rear venting cannot be used.
S1
**The framing depth/width does not take into account dry wall/wood or similar materials against the back /side wall. The framing depth
will need to change based on the thickness of the material
(example: M - 37-1/2" framing width + 1/2" drywall = 38")
(example: O - 19-1/4" framing depth + 1/2" drywall = 19-3/4")
**
**