22
Gem 54 Regency Gas Fire
installation
V1
H1
H
V
Horizontal Venting with Two (2) 90
o
Elbows
Horizontal Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
Option
V
H + H1
With these options,
maximum total pipe
length is 9m with
minimum of 1.8m total
vertical and maximum
3m total horizontal.
A)
.6m Min.
1.2m Max.
B)
.9m Max.
1.8m Max.
C)
1.2m Max. 2.4m Max.
D)
1.5m Max. 2.7m Max.
E)
1.8m Max. 3m Max.
Please note minimum .3m between 90
o
elbows is
required.
VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 1, no adjustment
required.
One 90
o
elbow = Two 45
o
elbows.
Option
V
H
V+ V1
H+ H1
With these options,
max. total pipe length
is 9m with min. of 3.4m
total vertical and max.
2.7m total horizontal.
A)
.6m Min.
.3m Max.
.9m Min.
.6m Max.
B)
.6m Min.
.6m Max.
1.5m Min
1.2m Max.
C)
.9m Min.
.6m Max.
2.1m Min. 1.5m Max.
D)
1.2m Min.
.9m Max.
2.7m Min. 1.8m Max.
E)
1.5m Min.
1.2m Max.
3m Min.
2.1m Max.
F)
1.8m Min.
1.8m Max.
3.3m Min
2.7m Max.
Please note minimum .3m between 90
o
elbows is required.
VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 1, no adjustment required.
H
H1
V