Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
31
MAINTENANCE
INSTRUCTIONS
Any maintenance required accessing the
glass door of the unit must be performed
by an authorized service person.
1)
Always unplug the power cord before
cleaning. For relighting, refer to lighting
instructions. Keep the burner and control
compartment clean by brushing and vacu-
uming at least once a year. When cleaning
the logs, use a soft clean brush as the logs
are fragile and easily damaged.
2)
Clean glass (never when unit is hot), appli-
ance, louvres, and door with a damp cloth.
Never use an abrasive cleaner. The gold
louvres (and optional gold door) may be
scratched if abrasives are used to clean
them.
The
heater
is
fi nished in a heat resistant
paint and should only be refi nished with
heat resistant paint (not with wall paint).
Regency uses StoveBright Paint - Metallic
Black #6309.
3)
Make a periodic check of burner for proper
position and condition. Visually check the
fl ame of the burner periodically, making sure
the fl ames are steady; not lifting or fl oating.
If there is a problem, call an authorized
service person.
4)
The appliance and fl ueing system must be
inspected before use, and at least annu-
ally, by an authorized fi eld service person,
to ensure that the fl ow of combustion and
ventilation air is not obstructed.
During the annual service call, the burners
should be removed from the burner tray
and cleaned. Replace the embers - do not
block the pilot or burner ports.
5)
Keep the area near the appliance clear and
free from combustible materials, gasoline
and other fl ammable vapours and liquids.
General Flue Maintenance
Conduct an inspection of the fl ueing system
semi-annually. Recommended areas to inspect
as follows:
1)
Check the Flueing System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or streaks,
and in extreme cases, holes. These com-
ponents should be replaced immediately.
2)
Remove the Cap, and shine a fl ashlight
down the Flue. Remove any bird nests, or
other foreign material.
COPY OF THE LIGHTING PLATE INSTRUCTIONS
OPERATING INSTRUCTIONS