Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
28
WIRING DIAGRAM
INSTALLATION
REMOTE CONTROL
Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter and a wall mounting plate.
1)
Choose a convenient location to mount the hand held transmitter, protection from extreme heat is very important.
The remote can also be used as a wall thermostat.
CAUTION: Label all wires prior
to disconnection when servic-
ing controls. Wiring errors can
cause improper and dangerous
operation.
This heater requires a 240V A.C. supply for the
gas control to operate. A 240V A.C. power supply
is needed for the fan/blower operation.
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
FLAME SENSOR
SPARK IGNITOR
PILOT
BROWN (ACTIVE)
BLUE (NEUTRAL)
VIOLET
BLUE
BROWN
WHITE
RED
BLACK
FA
N
FAN
Hi
Com
Lo
Hi
Lo
Com
TERMINAL
BLOCK
BLACK
RED
WHITE
SIT 201 IGNITION CONTROL MODULE
JUMPER
2 1
ORANGE
ORANGE
MODULE - SPARK
BLACK
12 11
9
10
8 7 6 5 4 3 2
RESET SWITCH (NC)
YELLOW
VIOLET
YELLOW
BLACK
1
SIGMA 845 VALVE
RED
BLUE
GREEN
BROWN
3
5
4
2
1
SIT
MODULATING
(MD)
COIL
ORANGE
ORANGE
RED
RED
MODULE - FLAME
MODULE - GROUND
GREEN
MED
FAN
NEUTRAL
NEUTRAL
COMMAND BOX
ACTIVE
LOW
THERM
HIGH
TH2
TH1
MOD1
MOD2
GND
GND
GND