12
Regency
®
F33-3 Freestanding Gas Stove
Regency Freestanding Gas
OPTIONAL REMOTE WALL
SWITCH
1)
Run wire through the opening in the rear of the unit. Be careful not
to damage wire.
Note: We recommend a maximum of 4.5m of wire but if you
wish to go with a longer run use the Thermostat Wire
Table.
2)
Connect wire to wall switch and install into receptacle box.
Caution:
Do not wire millivolt wall switch for gas appliance to a
240V power supply.
OPTIONAL REMOTE CONTROL
INSTALLATION
Use the Optional Regency
®
Remote Control Kit approved for this unit.
Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter, a receiver
and a wall mounting plate.
1)
Choose a convenient location on the wall to install the receiver and
the receptacle box (protection from extreme heat is very important).
Run wires from the fireplace to that location. Use Thermostat Wire
Table.
2)
Connect the two wires to the gas valve. See diagram below.
3)
Install a 9V alkaline battery in both receiver and the transmitter.
Install the receiver and cover in the wall. The remote control is
now ready for operation.
OPTIONAL WALL THERMOSTAT
INSTALLATION
A wall thermostat may be installed if desired.
Note: Preferable if the thermostat is installed on an interior
wall.
Use a CSA, UCL or UL approved millivolt thermostat, 250-750 millivolt
rated. A non-anticipator type thermostat must be used.
Thermostat Wire Table
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
15.24 m
9.75 m
6.10 m
3.66 m
2.71 m
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
FINAL CHECK
Before leaving this unit with the customer, the installer must ensure
that the appliance is firing correctly. This includes:
1)
Checking the operating pressure (see data label)
2)
If required, adjusting the primary air to ensure that the flame does
not carbon. First allow the unit to burn for 15 min. to stabilize.
3)
Check for proper draft.
CAUTION:
Any alteration to the product that causes sooting or
carboning that results in damage to the unit is not the responsibility
of the manufacturer and will not be covered by the warranty.
INSTALLATION