Regency F2400M Owners & Installation Manual Download Page 5

 

Regency 2400 Freestanding Woodstove

  |     

5

5

safety decal

This is a copy of the label that accompanies each 
Regency  Freestanding Woodstove  (F2400M). 
We have printed a copy of the contents here 
for your review.

NOTE:

  Regency  units  are  constantly  being 

improved.  Check  the  label  on  the  unit  and  if 
there is a difference, the label on the unit is the 
correct one.

SAFETY LABEL FOR F2400M

Part #:      918-172e

Size:       6.53" H x 11.53" W (File at 100%)

Color:     Everything printed black on grey except what is indicated is printed red on grey.

June 19/07: updated OMNI logo and standard as per SCC requirement

.

Mar 1/10: Updated Omni Logo

Jan. 21/13: Updated yrs. of manufacture.

Feb. 17/14: Added French as per OMNI

May 06/15: Rev. E - Updated yrs. of manufacture/removed 1990 EPA info

MODEL:  REGENCY  MEDIUM  FREESTANDING STOVE -  F2400M

TESTED TO:  UL-1482-2011 / ULC-S627-00 / UL-737-2011  REPORT NO:219-S-02-2

THE F2400M MEETS UL737 STANDARD FOR FIREPLACE STOVES WHEN A FIRESCREEN IS PROVIDED.

MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT         MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.    

MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"

THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.

F2400M WITHOUT 

AIRMATE SHIELD

F2400M WITH 

AIRMATE SHIELD

K  405 mm  /  16 in

L  150 mm  /  6 in

M  150 mm  /  6 in

FOR USE WITH SOLID WOOD FUEL ONLY.  USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION.  DO NOT OBSTRUCT COMBUSTION 

AIR OPENINGS.  OPERATE ONLY WITH FIREBRICKS IN PLACE.  RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED. 

IF INSTALLED IN A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. WHEN OPERATED WITH DOORS OPEN THE 

MANUFACTURER SUPPLIED SCREEN MUST BE USED. DO NOT USE GRATE OR ELEVATE FIRE.  BUILD WOOD FIRE DIRECTLY ON HEARTH.  DO NOT OVERFIRE - IF HEATER 

OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING.  INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY.  UNDER CERTAIN CONDITIONS OF USE 

CREOSOTE BUILDUP MAY OCCUR RAPIDLY.  KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER.  REPLACE GLASS ONLY WITH NEOCERAM 

GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS INDICATED 

OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.

OPTIONAL COMPONENT: FAN (846-515), ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, SCREEN DOOR (846-101)

DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.

COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR

IN CANADA: 

LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH  LISTED CHIMNEY SYSTEM: SECURITY MODEL 

S2100, ICC EXCEL 2100, SELKIRK SENTINAL CF.

IN USA:   LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA 

VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL.  CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS 

SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR 

METAL-FAB TEMP/GUARD, AMERI-TEC HS,  ICC EXCEL 2100 .  USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS. 

AUTEUR MINIMALE DU PLAFOND DE L’ALCÔVE : 2.15 M / 7 PL   PROFONDEUR MAXIMALE DE L’ALCÔVE : 915 MM / 36 PO

DÉGAGEMENT MINIMAL DU PLAFOND POUR UN CONNECTEUR HORIZONTAL : 455 MM / 18 PO.

L’ESPACE AU-DESSOUS DU POÊLE NE DOIT PAS ÊTRE OBSTRUÉ. UTILISER SEULEMENT AVEC LES BRIQUES RÉFRACTAIRES EN PLACE.

POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. L’UTILISATION D’AUTRES COMBUSTIBLES PEUT ENDOMMAGER LE POÊLE ET CRÉER UNE CONDITION DANGEREUSE. 

NE PAS OBSTRUER LES OUVERTURES D’AIR DE COMBUSTION. UTILISER SEULEMENT AVEC LA PORTE FERMÉE – OUVRIR LA PORTE DE CHARGEMENT POUR ALIMENTER 

LE FEU SEULEMENT. NE PAS UTILISER DE GRILLE À BÛCHES NI SURÉLEVER LE FEU. MONTER LE FEU DE BOIS DIRECTEMENT SUR L’ÂTRE. NE PAS SURCHAUFFER – SI 

LE POÊLE OU LE CONNECTEUR DE CHEMINÉE SE MET À ROUGIR, VOUS SURCHAUFFEZ. INSPECTEZ ET NETTOYEZ FRÉQUEMMENT LA CHEMINÉE ET LE CONNECTEUREN 

CERTAINES CONDITIONS D’UTILISATION, UN DÉPÔT DE CRÉOSOTE PEUT SE FORMER RAPIDEMENT. GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES 

ÉLOIGNÉS DU POÊLE. REMPLACEZ LA VITRE SEULEMENT PAR DU VERRE EN NEOCERAM. LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR DES MATÉRIAUX NON 

COMBUSTIBLES DÉPASSANT DU DESSOUS, DU DEVANT ET DES CÔTÉS DU POÊLE, TEL QU’INDIQUÉ, OU JUSQU’AU MATÉRIAU COMBUSTIBLE LE PLUS PRÈS PERMIS.

COMPOSANTS EN OPTION : VENTILATEUR (846-515), ALIMENTATION ÉLECTRIQUE : 115 VOLTS, 60 HZ, 2 AMP.

DANGER : RISQUE D’ÉLECTROCUTION. DÉCONNECTER L’ALIMENTATION ÉLECTRIQUE AVANT DE FAIRE L’ENTRETIEN DU POÊLE. NE PAS INSTALLER LE CORDON 

ÉLECTRIQUE SOUS OU DEVANT L’APPAREIL.

COMPOSANTS EXIGÉS POUR INSTALLATION DANS UNE MAISON MOBILE : KIT DE PRISE D’AIR EXTÉRIEUR ET L’UN DES CONNECTEURS DE CHEMINÉE À DOUBLE PAROI 

SUIVANTS :

AU CANADA : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, OU OLIVER MACLEOD PRO-VENT PV, AVEC SYSTÈME DE CHEMINÉE 

HOMOLOGUÉ : SECURITY MODÈLE S2100, ICC EXCEL 2100, SUPER VENT 2100, SUPERPRO 2100, CF SENTINAL.

AUX ÉTATS-UNIS : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, 

SIMPSON DURA VENT MODÈLE DVL, GSW SUPER PIPE 6, METAL-FAB À DOUBLE PAROI. CONNECTÉ À L’UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS : 

SECURITY MODÈLE S2100 OU MODÈLE ASHT, SELKIRK MODÈLE SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODÈLE SC OU METAL-FAB TEMP/

GUARD, AMERI-TECHS, ICC EXCEL 2100, SIMPSON DURA PLUS HTC. UTILISER LES COMPOSANTS DE CHEMINÉE SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION.

244

 CAUTION 

HOT WHILE IN OPERATION DO NOT TOUCH.  KEEP CHILDREN,

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.

ATTENTION

CHAUD DURANT LE FONCTIONNEMENT. NE TOUCHEZ PAS. 

ÉLOIGNEZ LES ENFANTS, LES VÊTEMENTS ET LES MEUBLES. 

LE CONTACT PEUT CAUSER DES BRÛLURES DE LA PEAU.

LISEZ LA PLAQUE SIGNALÉTIQUE ET LES INSTRUCTIONS

MADE IN CANADA / FAIT AU CANADA

MANUFACTURED BY/ FABRIQUÉ PAR:

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.

6988 VENTURE ST.

DELTA, BC  V4G 1H4

LISTED SPACE HEATER, SOLID FUEL TYPE,  ALSO 

SUITABLE FOR MOBILE HOME INSTALLATION /  

APPAREIL DE CHAUFFAGE AMBIANT HOMOLOGUÉ 

À COMBUSTIBLE SOLIDE, CONVENANT AUSSI

POUR INSTALLATION DANS UNE MAISON MOBILE 

FLOOR PROTECTION*

PROTECTION DE PLANCHER*

Au Canada, la protection de plancher doit dépasser de 

18 po (457 mm) à l’avant et de 8 po (200 mm) de chaque 
côté du poêle et derrière le 

poêle.

* In Canada, floor protection must extend 18" (450mm) 

to the front and 8" (200mm) to each side and back of 

the stove.

DO NOT REMOVE THIS LABEL/

 NE RETIREZ PAS CETTE ÉTIQUETTE

244

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.  

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.  

USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT 

FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.  

SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A 

CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.  DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE 

WALL OR CEILING.  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

INSTALLER ET UTILISER SEULEMENT SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DU FABRICANT. 

CONTACTER LES RESPONSABLES DU BÂTIMENT OU DU SERVICE-INCENDIE DE VOTRE RÉGION POUR CONNAÎTRE 

LES RESTRICTIONS ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION. UTILISER UN CONNECTEUR D’UN DIAMÈTRE 

MINIMAL DE 150 MM (6 PO) 24 MSG EN ACIER NOIR OU 26 MSG EN ACIER BRONZÉ AVEC CHEMINÉE PRÉFABRIQUÉE 

HOMOLOGUÉE UL103 HT CONÇUE POUR UTILISATION AVEC COMBUSTIBLES SOLIDES OU UNE CHEMINÉE DE MAÇON-

NERIE.

VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT CONCERNANT LES PRÉCAUTIONS  

EXIGÉES POUR INSTALLER UNE CHEMINÉE TRAVERSANT UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES. 

NE FAITES PAS TRAVERSER LE CONNECTEUR DE CHEMINÉE DANS UN MUR OU PLAFOND EN MATÉRIAUX COMBUS-

TIBLES. NE RACCORDEZ PAS CE POÊLE À BOIS À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

DÉGAGEMENTS MINIMUMS AUX MATÉRIAUX COMBUSTIBLES

F2400M WITH AIRMATE SHIELD

F2400M  WITHOUT AIRMATE SHIELD

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

MEASURE  

  

  

       FLUE

FROM  

          HEATER  

        CENTER-LINE

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

SIDEWALL  A  457  mm / 18 in  D 762 mm / 30 in

BACKWALL  B 305  mm / 12 in  E  470 mm / 18.5 in

CORNER 

C 165  mm / 6.5 in  F  457 mm / 18 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME 

SIDEWALL  A  380 mm / 15 in  D 685 mm / 27 in

BACKWALL  B 165 mm / 6.5 in  E  330 mm / 13 in

CORNER 

C 152 mm / 6  in  F  444 mm / 17.5in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL  A  380 mm / 15  in  D 685 mm / 27 in

BACKWALL  B 165 mm / 6.5in  E  330 mm / 13 in

CORNER 

C 152  mm / 6 in 

F  444 mm / 17.5 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - ALCOVE

SIDEWALL  A  406  mm / 16 in  D 711  mm / 28  in

BACKWALL  B 280  mm / 11 in  E  444  mm / 17.5 in

CORNER 

C 152  mm / 6 in 

F  444  mm / 17.5 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME 

SIDEWALL  A  380  mm / 15 in  D 685 mm / 27 in

BACKWALL  B 140  mm / 5.5 in  E 304 mm / 12 in

CORNER 

C 102  mm / 4 in 

F  393 mm / 15.5 in 

SIDEWALL  A  380 mm / 15  in  D 685 mm / 27 in

BACKWALL  B 140  mm / 5.5 in  E  304 mm / 12 in

CORNER 

C 102  mm / 4 in 

F  393 mm / 15.5 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - ALCOVE

SIDEWALL  G 380 mm / 15 in  I  685 mm / 27 in

BACKWALL  H 165 mm / 6.5 in  J  330 mm / 13 in

MEASURE  

  

  

       FLUE

FROM  

        HEATER           CENTER-LINE

SIDEWALL  G 380 mm / 15 in  I  685 mm / 27 in

BACKWALL  H 140 mm / 5.5in  J  304  mm / 12 in

918-172e  

 JAN    FEB    MAR     

APR     MA

Y   JUN     JUL

    

AUG    SEPT   OCT   NOV     DEC

DA

TE OF MANUF

ACTURE

2015

2017

2016

Summary of Contents for F2400M

Page 1: ...Freestanding Woodstove 02 26 16 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference Owners Installation Manual Tested by F2400 Video www regency fire com French Manual http bit ly 1myB2FA Manuel en Français http bit ly 1myB2FA ...

Page 2: ...ere the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual or if any parts are removed It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURN UNTREATED WOOD ONLY O...

Page 3: ...Regency 2400 Freestanding Woodstove 3 3 Modular Parts F2400 Video ...

Page 4: ...ion 18 Flue Baffle Secondary Air Tube Installation 18 Stainless steel smoke deflector adjustment replacement 19 Brick Installation 20 Classic Door Handle 20 Contemporary Door Handle 20 Glass Installation 20 Step by step Optional Accessories Installation 20 Screen Door 21 Seasoned wood 22 Operating Instructions 23 Draft Control 23 First Fire 23 Fan Operation 24 Ash Disposal 24 Safety Guidelines and...

Page 5: ...URS DE CHEMINÉE À DOUBLE PAROI SUIVANTS AU CANADA CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI SECURITYMODÈLE DP OU OLIVER MACLEOD PRO VENT PV AVEC SYSTÈME DE CHEMINÉE HOMOLOGUÉ SECURITY MODÈLE S2100 ICC EXCEL 2100 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX ÉTATS UNIS CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI SECURITY MODÈLE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DU...

Page 6: ...MODÈLE S2100 ICC EXCEL 2100 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX ÉTATS UNIS CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI SECURITY MODÈLE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MODÈLE DVL GSW SUPER PIPE 6 METAL FAB À DOUBLE PAROI CONNECTÉ À L UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS SECURITY MODÈLE S2100 OU MODÈLE ASHT SELKIRK MODÈLE SSII OLIVER MACLE...

Page 7: ...Regency 2400 Freestanding Woodstove 7 7 dimensions F2400M UNIT DIMENSIONS Classic Door Contemporary Door ...

Page 8: ...8 Regency 2400 Freestanding Woodstove 8 dimensions S2400M UNIT DIMENSIONS Classic Door Contemporary Door ...

Page 9: ...osi tion the stove with the flue collar centered under the installed chimney 10 In areas of seismic activity Regency rec ommends that your unit is secured to the floor by using the bolt down holes inside the pedestal the same ones used in Mobile Home installations 11 For residential installations using 6 C Vent single wall the chimney connector must be at least 24 gauge steel Do not use galvanized...

Page 10: ... also required for air space between the apliance and wall ceiling Residential Installation C Vent Single Wall Unit From Unit From Corner From Flue Center Line A B C D E F Medium F2400M with Airmate 15 381 mm 5 5 139 mm 4 101 mm 27 685 mm 12 304 mm 15 5 393 mm with Rear Deflector 15 381 mm 6 5 165 mm 6 152 mm 27 685 mm 13 330 mm 17 5 444 mm Medium S2400M Step Stove 16 406 mm 11 279 mm 6 152 mm 28 ...

Page 11: ...t be installed with a listed double wall connector to the ceiling level Note Minimum alcove ceiling height 84 Maximum depth of alcove 36 NOTE This clearance is also required for air space between the appliance and wall ceiling Unit From Unit From Corner From Flue Center Line G H I J K L Medium F2400M with Airmate 15 381 mm 5 5 139 mm 27 685 mm 12 304 mm 54 1371 mm 48 1219 mm with Rear Deflector 15...

Page 12: ... shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for shipping and handling It allows for a handhold on the top of the stove Before placing in the Step Stove in its final position the side shields must be raised Loosen the screws on the rear on the stove 3 per side slide the side panel up as far as pos sible and then secure by tightening the screws Pedestal Ass...

Page 13: ... to initiallytrywiththeminimumrequired height and then if problems do arise add additional height at a later date 4 Slide the roof flashing over your chimney and seal the flashing to the roof with roofing compound Secure the flashing to your roof with nails or screws 5 Place the storm collar over the flashing sealing the joints with a silicone caulking 6 Fasten the raincap with spark screens if re...

Page 14: ...inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connect ing the stove through a combustible wall to a masonrychimney specialmethodsareneeded MASONRY FIREPLACE There are listed kits available to connect a stove to a masonry fireplace The kit is an adapter that...

Page 15: ...chimney clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through Thereshallbeam...

Page 16: ... and may cause damage An uncontrol lable burn or excessive temperature indicates excessive draft Inadequate draft may cause back puffing into the room and plugging of the chimney Inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints Ensure the heater is installed in areas that are not too close to neighbors or in valleys that would cau...

Page 17: ... chassis of the Mobile Home 4 A listed double wall connector chimney system roof thimble spark arrestor and roof flashing kit suitable for use in Mobile Homes must be used 5 If the chimney exits the Mobile Home at a loca tion other than through the roof and exits at a point 7ft 2130mm or less above the ground level on which the Mobile Home is positioned a guard or method of enclosing the chimney s...

Page 18: ...the firebox 1 If all 4 air tubes are installed continue on to Step 2 if not follow the instructions below Install the air tube into the holes in the side channels The notch goes on the right hand sidewiththeairholesfacingtowardthedoor LISTED COMPONENTS FOR MOBILE HOME INSTALLATION TheRegencyF2400MandS2400M Freestand ing pedestal units are approved for installation in a Mobile Home if one of the fo...

Page 19: ... bolts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the deflector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from the back of the unit through the top Ens...

Page 20: ... bricks from the floor of the firebox 2 If using ashdrawer discard cover plate 3 Remove the ash dump cover plates one inside the firebox and one on the underside of the firebox by removing the two nuts and bolts holding the 2 plates together from inside the firebox 4 Pushtheashplugintotheholeinsidethefirebox and replace all the bricks except for the brick over the ash plug refer to the brick diagr...

Page 21: ...ngerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a prop erly grounded three prong receptacle Do not cut or remove the grounding prong from this plug SCREEN DOOR Hook screen to the inside on the right side of the firebox door opening Lock in place by...

Page 22: ...sides Softer woods like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pieces of firewood may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many indi...

Page 23: ...to be expected as the high temperature paint becomes sea soned Windows and or doors should be left open to provide adequate ventilation while this temporary condition exists Burning the stove at a very high temperature the first few times may damage the paint Burn fires at a moderate level the first few days 8 Do not place anything on the stove top during the curing process This may result in dama...

Page 24: ... exhaust fans Ensure adequate ventilation and correct chimney location CAUTION Certain fuels such as charcoal and wet wood can crate the possibility of generating carbon monoxide CO CO is a dangerous by product hat is odourless and can cause seri ous injury ASH DISPOSAL During constant use ashes should be removed every few days The Ash Drawer option features a convenient ash dump for easy removal ...

Page 25: ...orrect operation and longevity of your RegencyWoodheater Theyshouldbeinspected on a regular basis and replaced if they show any signs of undue wear or damage Failure of any of these components can damage the heater and void warranty 5 Thechimneyandchimneyconnectorshould beinspectedatleastonceeverytwomonths during the heating season to determine is a creosote buildup has occurred 6 Have chimney sys...

Page 26: ...75 Ash Hole Cover Plate 13 Bolt 1 4 20 x 1 2 Hex Head 14 820 376 Retainer Plate Ash Dump Top 15 Nut 1 4 20 Hex 16 846 570 7 8 Door Gasket Repair Kit 17 948 079 bn Spring Hinge Cap Nickel each 19 948 135 Spring Handle Large Nickel 20 948 136 Spring Handle Small Nickel F2400M STOVE MAIN ASSEMBLY W CLASSIC DOOR Part Description 846 515 Complete Fan Blower Assy 120 V 25 910 684 Power Cord 120 V 27 910...

Page 27: ... Top 15 Nut 1 4 20 Hex 16 846 570 7 8 Door Gasket Repair Kit 17 948 082 Hinge Cap Black each 19 156 241 Cast Handle 20 948 144 Small Spring Handle Black F2400M STOVE MAIN ASSEMBLY W CONTEMPORARY DOOR Part Description 846 515 Complete Fan Blower Assy 120 V 25 910 684 Power Cord 120 V 27 910 142 Thermodisc Fan Auto ON OFF 28 910 138 Manual Auto Switch 2 way 29 910 140 Fan Speed Switch HI OFF LOW 3 w...

Page 28: ...Assembly 16 846 570 7 8 Door Gasket Repair Kit 17 948 079 BN Hinge Cap Nickel each 19 948 135 Spring Handle Large Nickel 20 948 136 Spring Handle Small Nickel Part Description 846 515 Complete Fan Blower Assy 120 V 25 910 684 Power Cord 120 V 27 910 142 Thermodisc Fan Auto ON OFF 28 910 138 Manual Auto Switch 2 way 29 910 140 Fan Speed Switch HI OFF LOW 3 way 30 910 157 P Fan Blower Motor 120 V 36...

Page 29: ... 570 7 8 Door Gasket Repair Kit 17 846 918 Hinge Caps Gold 2 set 948 082 Hinge Cap Black each 19 156 241 Cast Handle 20 948 144 Small Spring Handle Black Part Description 846 515 Complete Fan Blower Assy 120 V 25 910 684 Power Cord 120 V 27 910 142 Thermodisc Fan Auto ON OFF 28 910 138 Manual Auto Switch 2 way 29 910 140 Fan Speed Switch HI OFF LOW 3 way 30 910 157 P Fan Blower Motor 120 V 36 033 ...

Page 30: ...awer Lid Assy 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle 56 020 911 Bottom Shield Medium 57 Blanking Plate Btm Shield 850 101 Ashdrawer Kit Btm Shield 55 Ashdrawer Bottom Shield 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle 140 850 126 Legs Cast Black 850 128 Legs Cast Brush Nickel 948 223 Regency Logo Nickel 919 542 Manual Not available as a replacement part PEDESTAL BOTTOM SHIELD ...

Page 31: ...FREESTANDING WOOD STOVES F2400 S2400 Firebrick Replacement NOTE This kit contains one spare brick in case of breakage Description 70 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 72 Brick Partial 1 1 4 x 2 x 4 1 2 74 Brick Partial 1 1 4 x 4 1 2 x 3 1 2 76 Brick Partial 1 1 4 x 2 x 9 2 ...

Page 32: ...32 Regency 2400 Freestanding Woodstove 32 notes ...

Page 33: ...Regency 2400 Freestanding Woodstove 33 33 notes ...

Page 34: ...34 Regency 2400 Freestanding Woodstove 34 notes ...

Page 35: ... the warranty will be invalid Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing firebrick back sides bottom or trim It does not cover installation and operational related problems such as over firing use of corrosive driftwood wood preservatives metal foils coal plastic garbage sulphur mill ends oils solvents petroleum products railroad ties paper ...

Page 36: ...____________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your...

Reviews: