Regency
®
E18E-11 Gas Fireplace Insert
| 63
installation
919-831a
11.29.17
MONTIGO 28 F3 ONLY
12
.
To install fi ller piece, slide under faceplate and secure to
backside of faceplate with magnets.
13. Completed install of fi ller piece.
10.
Locate the 'DC supply' wire on the wiring harness, the wire
will be clearly marked. Attach the AC adaptor to the DC
supply wire as shown. Do not plug into a 120V circuit until
the install is complete.
DC supply wire from wiring harness
AC adaptor
11.
Install control cover, adjust horizontal alignment by sliding
control cover to ensure even spacing on both sides. Ensure
control cover is seated down all the way.
Diagram 13.7
DRAFT RELIEF OPENINGS MUST NOT BE COVERED OR BLOCKED.
Diagram 13.6
Diagram 13.5
8. Attach front faceplate with 4 screws (2 on each mounting
bracket). (Touch up screws with black paint, after install.)
9. Reinstall glass door and screen removed from step 1.
5
E18E