Regency Bellavista® B41XTE -10 Gas Fireplace
|
30
installation
RIGID PIPE VENTING SYSTEMS
BASIC HORIZONTAL & VERTICAL TERMINATIONS
Rigid Pipe Vent Systems offer a complete line of
component parts for installation of both horizontal
and vertical installations. Many items are offered
in decorative black, as well as galvanized finish.
The minimum components required for a basic
Horizontal Termination are:
1 AstroCap XL Termination Cap
1 90
o
Elbow
1 Rigid Pipe Adaptor
1 Wall Thimble
1 Length of rigid pipe to suit wall thickness
The minimum components required for a basic
Vertical Termination are:
1 Vertical Termination Cap
1 Rigid Pipe Adaptor
1 Lengths of pipe to adequately
penetrate roof
1 Ceiling Firestop
1 Flashing
1 Storm Collar
Wall thickness is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl, furring
strips may be used, instead of a vinyl siding
standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including
furring strips.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
The FPI AstroCap XL
TM
is certified for installations using FPI venting systems as well as Simpson Dura-Vent
®
Direct Vent Pro, ICC Excel and Selkirk
Direct-Temp. AstroCap XL
TM
is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or
proprietary trademarks of Simpson Dura-Vent Co. Inc.
This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
Simpson DV Pro, Metal-Fab Sure-Seal, ICC
Excel and Selkirk Direct-Temp systems. Use
of these systems with the Rigid Pipe adaptor
is deemed acceptable and does not affect the
Warnock Hersey/Intertek listing of components.
WARNING:
Do not combine venting components from
different venting systems.
Exception: However, use of the the AstroCap
XL
TM
is acceptable with all systems.
Alternate Snorkel
Termination Cap
HOT
Alternate
Horizontal Termination
Caps
Rigid Pipe
Adaptor (770-994)
Pipe Length
Vertical Terminal
Storm Collar
Flashing
Ceiling Firestop
Pipe
Length
Pipe Length
90 Elbow
o
AstroCap XL
Termination Cap
(Part #946-623/P)
Wall Thimble
(Mandatory in all
Horizontal Terminations)
Vinyl Siding
Standoff (Optional)
Vent Guard - if required*
(Part #946-506/P)
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.