38

     | 

Regency Ultimate™ U900E-11 Gas Fireplace

installation

Diagram 4

Diagram 3

7.

  Ensure that  the pipe clearances to combustible 

materials are maintained (Diagram 3). Install 
the termination cap.

Note:  If installing termination on a vinyl siding 

covered wall, a vinyl siding standoff or 
furring strips must be used to ensure 
that the termination is not recessed into 
the siding.

 

The  four  wood  screws  provided  should  be 
replaced with appropriate fasteners for stucco, 
brick, concrete, or other types of sidings.

8.

  Before connecting the horizontal run of vent pipe 

to the vent termination, slide the Wall Thimble  
over the vent pipe. The wall thimble is required 
for all horizontal terminations.

9.

  Slide the appliance and vent assembly towards 

the wall carefully inserting the vent pipe into the 
vent cap assembly. It is important that the vent 
pipe extends into the vent cap sufficient distance 
so  as  to  result  in  a  minimum  pipe  overlap  of 
1-1/4  inches  (32mm).  Secure  the  connection 
between the vent pipe and the vent cap.

10.

 Install wall thimble in the center of the framed  

hole and attach with wood screws (Diagram 4).

Install the vent system according to the manufacturer's 
instructions included with the components.

1.

  Set  the  unit  in  its  desired  location.  Check  to 

determine if wall studs or roof rafters are in the 
way when the venting system is attached. If this 
is the case, you may want to adjust the location 
of the unit. Rough in the gas preferably on the 
right side of the unit and the electrical (junction 
block is on the left side) on the left.

2.

  Direct Vent pipe and fittings are designed with 

special  twist-lock  connections  to  connect  the 
venting system to the appliance flue outlet. A 
twist-lock appliance adaptor is required.

3.

  In conjunction with the Approved Vent system, 

install  the  adaptor  after  the  unit  is  set  in  its 
desired location. Put a bead of Mill-Pac inside 
the outer section of the adapter and a bead of 
Mill-Pac  on the inner collar. Slip the adapter over 
the existing inner and outer flue collar. Fasten to 
the outer collar only with the 3 supplied screws 
(drilling pilot holes will make this easier).

4.

  Level the fireplace and fasten it to the framing 

using nails or screws through the side nailing 
strips.

Diagram 1

Note:  For  best r esults and optimum 

performance with each approved 
v e n t i n g   s y s t e m ,  i t   i s   h i g h l y 
recommended to apply Mill-Pac

 

 

sealant (supplied) to every inner 
pipe connection. Failure to do so 
may result in drafting or performance 
issues not covered under warranty.

Horizontal runs of vent must be supported every 
3 feet (0.9meter). Wall straps are available for 
this purpose.

6.

  Mark the wall for a square hole.-see chart to left 

for size. The center of the square hole should line 
up with the center-line of the horizontal pipe. Cut 
and frame the square hole in the exterior wall 
where the vent will be terminated. See diagram 
2 for center line requirements.

 

If the wall being penetrated is constructed of 
non-combustible  material,  i.e.  masonry  block 
or concrete, an 7" (178mm) diameter  hole is 
acceptable.

Note:
 a)

  The horizontal run of vent must be level, or 

have a 1/4 inch rise for every 1 foot of run 
towards  the  termination.  Never  allow  the 
vent  to  run  downward.  This  could  cause 
high  temperatures  and  may  present  the 
possibility of a fire. 

 

b)

  The  location  of  the  horizontal  vent 

termination on an exterior wall must meet 
all local and national building codes. 

5.

  Assemble the desired combination of pipe and 

elbows to the appliance adaptor and twist-lock 
for a solid connection.

Recommended Framed Opening 

Size

Vent Size

Framing Size

4" x 6 - 5/8"

10" x 10"

Horizontal Top*

3" (76mm)*

Horizontal Side

2 " (51mm)

Horizontal Bottom

2" (51mm)

Vertical Vent

2" (51mm)

Minimum Vent Clearances

to Combustibles

UNIT INSTALLATION WITH HORI-
ZONTAL TERMINATION 
4" X 6-5/8" VENTING

(Rigid Vent Systems)

Below are the recommended framing dimensions 
(inside measurements) for the  4" x 6-5/8"  rigid 
vent terminations - for use with a firestop or wall 
thimble.

*  Clearances  noted  below  must  be  maintained;  except 
when passing through a wall, ceiling or at the termination 
where  the  use  of  a  firestop  or  wall  thimble  reduces 
clearance to 1-1/2" (38mm).

CL

CL

mm

99

1

Min.  height

(Rigid)

center

of hole

Diagram 2

Summary of Contents for U900E-LP11

Page 1: ...not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appli ance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric...

Page 2: ...home where not prohibited by local codes This Direct Vent System Appliance must be installed in accordance with the manufacturer s installation instructions and the Manufactured Home Construction and...

Page 3: ...continuous pilot switch is in the on position in your remote control transmitter Each time the main burner shuts down manually or through the call from the thermostat the seven day timer starts again...

Page 4: ...m 36 Venting Arrangements Vertical Termination 37 with Co linear Flex System for both 37 Residential Manufactured Homes into Masonry Fireplaces 37 Unit Installation with Horizontal Termination 38 4 x...

Page 5: ...ed States or when such a standard is not applicable ANSI NCSBCSA225 1 NFPA501A Manufactured Home Installations Standard orANSI A119 2 ou NFPA501C Standard for Recreational Vehicles This appliance is o...

Page 6: ...Clean Edge Design size 40 1 8 W x 18 1 4 H Reference Description Inches Millimeters I Gas Connection Opening Height 1 11 16 43mm J Gas Connection Height 2 11 16 67mm K Gas Connection Inset 1 1 8 29mm...

Page 7: ...to make you aware of the following CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES...

Page 8: ...ntrol instructions Note In thermostat mode When the appliance is turned on the fan will not come on for the first 5 minutes if fan is turned on When the appliance is turned off the fan will not turn o...

Page 9: ...al injury or loss of life Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance Fo...

Page 10: ...hoice of standing or intermittent pilot CPI IPI 4 Thermostat and Smart thermostat functions 5 Accent light modulation 6 levels 6 Split flow valve 7 Comfort Fan speed modulation 6 levels This feature i...

Page 11: ...by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame...

Page 12: ...fan speed can be adjusted through six 6 speeds To activate this function use the Mode Key fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fa...

Page 13: ...asily changed from an inter mittent pilot ignition system IPI to a continuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as follows Keeps ventin...

Page 14: ...sPipePressure Testing section 13 Install standard and optional features Refer to the following sections a Log Install b Inner Door Frame c Outer Faceplate Verona surround d Finishing Trim e Enamel pan...

Page 15: ...e grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size G...

Page 16: ...tance that this fireplace and vent system be installed only in accordance with these instructions Clearance Dimension Measured From A Mantel Height min 20 508mm Top of Fireplace Opening B Sidewall on...

Page 17: ...Ensure the paint that is used on the mantel and the facing is high quality or the paint may discolour MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram Note A non combustible man...

Page 18: ...s set as far forward on the firebox as possible The nailing strips can be adjusted back up to 1 1 2 38mm to allow for varying thicknesses in non combustible material wall finishes INSTALLATION ACCESS...

Page 19: ...ing Wall Width 72 1 2 1842mm G Vent Centerline Height 39 991mm H Non combustible facing height 20 508mm Framing depth measurement is noted with the nailing strips set as far forward on the firebox as...

Page 20: ...strip adjust and retighten screws 4 Attach both vertical studs 466 126 to the vertical wood studs and secure using 6 screws 2 at bottom 2 at top and 2 on sides as shown NOTE Ensure the flat side of th...

Page 21: ...Install the vertical section of the deflector to the top of the firebox with 3 screws as shown below 3 Install the horizontal section of the deflector to the vertical section at the desired height wit...

Page 22: ...in the Low Voltage Junction box 5 Install batteries only if 120 volt power will not be used Batteries are only used if power is lost within the home and serve as a secondary power source Insert the 4...

Page 23: ...seams as normal We recommend using a product called Durabond high strength compound for the first coat This product can be found at any hardware store Mud must be cured as per manufacturer s recommend...

Page 24: ...materials See Clearances section Combustible materials can be laid against the side and back standoffs and the stove base 4 Non combustible material ie tile slate etc may be brought up to and overlap...

Page 25: ...egency Horizon Fireplace is as critical as the installation itself The temperatures around linear gas fireplaces are typically higher than would be acceptable for combustible materials Your Regency Ho...

Page 26: ...nded above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other a...

Page 27: ...side top of the firebox To set the vent restriction as indicated in the venting arrangements diagrams refer to the following instructions 1 Remove the glass door and inner panels see instructions in t...

Page 28: ...n of 4 feet 1 6 7 8 dia flexible liner 4 ft length 2 4 dia flexible liner 4 ft length 3 spring spacers 4 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 s...

Page 29: ...A N A N A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A...

Page 30: ...l for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent...

Page 31: ...Installation Wall Thickness inches Vent Length Required inches 3 1 4 6 3 4 11 14 5 8 Adj Pipe 7 3 4 16 1 4 17 24 Adj Pipe 7 1 4 8 3 4 6 12 9 9 4 1 4 5 3 4 6 9 WARNING Do not combine venting components...

Page 32: ...TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations using one 90o two 45o elbows equal one 90o elbow Note Must use optional rigid pipe adapter Part...

Page 33: ...nting Systems Two 45o elbows equal to one 90o elbow Vent must be supported at offsets Minimum distance between elbows is 1 ft 305mm Maintain clearances to combustibles as listed in the Clearances sect...

Page 34: ...options max totalpipelength is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required A 0 Min 2 Max 2 Min B 1 Min 2 Max 3 Min...

Page 35: ...90o elbows is required A 1 Min 3 Max B 2 Min 4 Max C 3 Min 5 Max D 4 Min 6 Max E 5 Min 7 Max F 6 Min 8 Max Restrictor Set 0 3 Factory Setting Option V H V V1 H H1 With these options max total pipe len...

Page 36: ...owever keeptheflexible linerasstraightaspossible avoidunnecessarybending The Air Intake pipe must be attached to the inlet air collar of the termination cap Required Parts Part Description 946 529 Co...

Page 37: ...on The shaded area in the diagrams show the allowable vertical terminations Restrictor Position Set 0 3 Factory Setting VENTING ARRANGEMENTS VERTICAL TERMINATION WITH CO LINEAR FLEX SYSTEM FOR BOTH RE...

Page 38: ...er flue collar Fasten to the outer collar only with the 3 supplied screws drilling pilot holes will make this easier 4 Level the fireplace and fasten it to the framing using nails or screws through th...

Page 39: ...ngs on the cap indicating which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the 4 supplied screws 6 Pull the centre...

Page 40: ...ushthepipe sections completely together then twist lock one section clockwise approximately one quarter turn until the two sections are fully locked The female locking lugs will not be visible from th...

Page 41: ...ions are in the fully twist locked position and sealed 5 Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2 The hole shouldbeofsufficientsizetomeettheminimum requir...

Page 42: ...FLEX VENT KIT 946 755 11 Secure inner ex pipe to pipe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer ex Diagra...

Page 43: ...am 1 Diagram 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roo...

Page 44: ...d or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Fl...

Page 45: ...og tray by removing 3 screws as shown in Diagram 2 below Diagram 2 Side Panel Front Lip Log Tray Screw Locations Side Panel Screws Log Tray Screws Front Lip Screws Diagram 3 Burner Screw Locations 7 R...

Page 46: ...upply is needed for the fan blower operation CAUTION Ensure that the wires do not touch a hot surface and are away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped...

Page 47: ...ed under warranty Log kit 466 930 contains the following pieces 1 Line up locators on Log 1 with corresponding locators on Log Tray as shown in Diagram 2 2 Line up locators on Log 2 with corresponding...

Page 48: ...and Log 3 as shown in Diagram 9 8 Line up locator on bottom of Log 7 with locator on Ceramic Log Burner as shown in Diagram 10 6 Log 5 final position shown in Diagram 8 6 Log 8 in final position show...

Page 49: ...n below to remove front trim piece 3 Reverse steps to reinstall 1 Remove front trim piece see instructions above 2 Remove two 2 screws in locations shown below to release panel clips 3 Remove panels b...

Page 50: ...bending in 6 tabs in locations shown below 4 Hook the inner door frame 3 and safety screen assembly 2 over the inner door trim 1 5 Bend the center tab up and secure with a screw to attach the inner do...

Page 51: ...ing that protrudes slightly beyond the faceplate Warning Turn off the unit by way of the wall switch or remote Allow unit to cool at least 10 min prior to removing the faceplate Diagram 1 Glass Surrou...

Page 52: ...hooking the left and right side mounting brackets into the mounting slots at the side of the firebox as shown below It is recommended that you use the first mounting slot the one closest to the door...

Page 53: ...first few fires a white film may develop on the glass front as part of the curing process The glass should be cleaned or the film will bake on and become very difficult to remove Use a non abrasive cl...

Page 54: ...start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the sy...

Page 55: ...isque de d clencher un incendie ou une explosion pouvant entra ner des d g ts mat riels ou des blessures pouvant tre mortelles Tout d faut d installation d ajustement de modification de service ou d e...

Page 56: ...t the cycling process WARNING CHILDREN AND ADULTS SHOULD BE ALERTEDTO THE HAZARDS OF HIGH SURFACE TEMPERATUREANDSHOULDSTAY AWAYTOAVOIDBURNSORCLOTH ING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPER...

Page 57: ...d be done by a licensed or qualified service person GLASS REPLACEMENT In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only Replacement neo...

Page 58: ...Reverse steps to reinstall fan 8 Remove access panel by removing eight 8 screws in locations shown in Diagram 4 Diagram 5 Fan Screws Diagram 4 Access Tray screws Diagram 1 Burner Side Panels 4 Remove...

Page 59: ...he other lower door latch 6 Pull the bottom of the door towards you until the door is angled away from the firebox by about 30 Lift the door up and over the upper door hooks 7 To install the glass doo...

Page 60: ...glass door front trim piece and inner panels see instructions in this manual 2 Remove logs 3 Remove burner side panels by lifting out as shown in Diagram 1 Diagram 1 Burner Side Panels 4 Remove enamel...

Page 61: ...ensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can inc...

Page 62: ...SIT 0 584 803 910 428 Receptacle Duplex White 910 430 Receptacle Cover Duplex Metal 396 042 F Glass Door Frame Tool 910 036 Pilot Orifice NG 910 037 Pilot Orifice LP 911 010 Stepper Motor NG 911 011...

Page 63: ...Regency Ultimate U900E 11 Gas Fireplace 63 parts list MAIN ASSEMBLY...

Page 64: ...IES 32 33 Part Description 32 636 914 Inner Door Frame Black 33 636 924 Faceplate Door Frame Black 636 951 Faceplate Door Frame Black Glass not shown 467 900 Steel Stud Framing not shown 636 936 Non C...

Page 65: ...Regency Ultimate U900E 11 Gas Fireplace 65 notes...

Page 66: ...ol Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Fi...

Page 67: ...s installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regul...

Page 68: ...U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized...

Page 69: ...n order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Det...

Page 70: ...70 Regency Ultimate U900E 11 Gas Fireplace warranty...

Page 71: ...Regency Ultimate U900E 11 Gas Fireplace 71 warranty...

Page 72: ...ation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ________________________________________________...

Reviews: