background image

4    | 

I1150 Regency Wood Insert

 

safety decal

This is a copy of the label that accompanies each 

I1150 Wood Insert

. We have printed a copy of 

the contents here for your review.

NOTE: 

  Regency  units  are  constantly  being 

improved.  Check the label on the unit and if 
there  is  a  difference,  the  label  on  the  unit  is 
the correct one.

Part #:  920-131

Colour:   Black on grey, except for selected items which are printed red.

Size: 

File is at 100%.   4" W x 10.7" H (excluding tear off

June 24/19:  Created decal

July 2/19:      Updated 'D' clearance

July 31/19: Updated as per Radu

LISTED FACTORY BUILT FIREPLACE INSERT

CERTIFIED FOR USE IN CANADA AND U.S.A.

MODEL: 

I1150

TESTED TO:

ULC S628-M93  / UL 1482-2011 (R2015)

   

  

  

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE

531

COMPONENTS REQUIRED FOR INSTALLATION: 5.5" (140mm) or  6" (152mm)STAINLESS STEEL 

LINER LISTED CHIMNEY LINER.  

OPTIONAL COMPONENT: FAN PART#172-917, ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS

DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.

DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE.  FOR USE WITH SOLID WOOD FUEL 

ONLY.  DO NOT USE GRATE OR ELEVATE FIRE.  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE 

SERVING ANOTHER APPLIANCE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE WITH FEED 

DOOR CLOSED, OPEN TO FEED FIRE ONLY.  REPLACE GLASS ONLY WITH CERAMIC GLASS (5MM).  

INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE 

BUILD-UP MAY OCCUR RAPIDLY.  DO NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.

CAUTION: MOVING PARTS MAY CAUSE INJURY. DO NOT OPERATE UNIT WITH A

REMOVED PART OR PARTS.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS 

(MEASURED FROM INSERT BODY)

COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING (E) 

16 IN / 405MM TO  FRONT AND (G) 8IN / 205MM TO SIDES FROM FUEL DOOR. IN CANADA MUST 

EXTEND 18” TO FRONT.

THERMAL INSULATION WITH A R VALUE = 1.4 AT A DISTANCE OF 18" FROM FRONT OF DOOR 

OPENING FOR CANADA AND 16" FOR USA. IF UNIT RAISED 4.5" FROM FLOOR, NO THERMAL INSU-

LATION IS REQUIRED.

MANUFACTURED BY/ 
FABRIQUÉ PAR :
FPI FIREPLACE PRODUCTS 
INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC  V4G 1H4

HOT WHILE IN OPERATION

DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND 

FURNITURE AWAY.

CONTACT MAY CAUSE SKIN BURNS. 

READ ABOVE INSTRUCTIONS.

APPAREIL CHAUD LORSQU’IL FONCTIONNE. 

NE PAS TOUCHER. GARDER À DISTANCE DES ENFANTS, DES 

VÊTEMENTS ET DU MOBILIER.  

TOUT CONTACT PEUT CAUSER DES BRÛLURES.   

LIRE LES INSTRUCTIONS CI-DESSUS.

ATTENTION / DANGER

ADJACENT SIDEWALL  A)  15in / 380mm

MANTEL 

B)  20n / 510mm

TOP FACING 

C)  14in / 355mm

SIDE FACING 

D)  0.5in / 13mm

(to side surround)

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S

INSTALLATION AND OPERATING INSTRUCTIONS.  INSTALL AND USE ONLY

IN MASONRY FIREPLACE OR FACTORY BUILT FIREPLACE.

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND

INSTALLATION INSPECTION IN YOUR AREA.

 

    JAN

    FEB

 

  MAR

 

  APR

 

  M

AY

 

 JUN

 

 JUL

 

AUG

 

SEPT

 

OCT

 

NOV 

 

DEC

2021

2022

2023

2024

2025

(Duplicate Serial #)

DA

TE OF MANUF

ACTURE / DA

TE DE F

ABRICA

TION

MADE

 IN

 CANADA

 / 

FAIT

 AU

 CANADA

A

D

B

C

MUR LA

TÉRAL

ADJACENT

PIÈCES OBLIGATOIRES POUR L’INSTALLATION : GAINE DE CHEMINÉE HOMOLOGUÉE EN ACIER 

INOXYDABLE DE 5,5 PO (140mm) ou  6 PO (152mm).  

PIÈCE EN OPTION : VENTILATEUR PIÈCE N

O

172-917

CARACTÉRISTIQUES ÉLECTRIQUES : 115 VOLTS, 60 HZ, 0,6 AMPS.

DANGER : RISQUE D’ÉLECTROCUTION. DÉBRANCHER LE COURANT AVANT DE PROCÉDER À L’EN-

TRETIEN DE L’APPAREIL.

NE PAS RETIRER LES BRIQUES OU LE MORTIER DU FOYER EN MAÇONNERIE. À UTILISER AVEC 

UN COMBUSTIBLE SOLIDE EN BOIS SEULEMENT. NE PAS UTILISER DE GRILLE NI SURÉLEVER LE 

FEU. NE PAS CONNECTER CET APPAREIL À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE 

APPAREIL. FAIRE UN FEU DE BOIS DIRECTEMENT SUR L’ÂTRE.  FAIRE FONCTIONNER L’APPAREIL 

AVEC LA PORTE DE CHARGEMENT FERMÉE, L’OUVRIR SEULEMENT POUR ALIMENTER LE FEU. 

REMPLACER LA VITRE SEULEMENT AVEC UNE VITRE EN CÉRAMIQUE (5MM). FAIRE INSPECTER 

ET RAMONER LA CHEMINÉE À INTERVALLES RÉGULIERS. ACCUMULATION RAPIDE DE CRÉOSOTE  

DANS CERTAINES CONDITIONS. NE PAS SURCHAUFFER : SI L’ENCASTRABLE EST ROUGEOYANT, 

L’APPAREIL SURCHAUFFE.

ATTENTION : LES PIÈCES AMOVIBLES PEUVENT ENTRAÎNER DES BLESSURES. NE PAS FAIRE 

FONCTIONNER L’APPAREIL SI UNE OU PLUSIEURS PIÈCES ONT ÉTÉ ENLEVÉES.

DÉGAGEMENTS MINIMAUX AUX MATÉRIAUX COMBUSTIBLES

(MESURES PRISES DEPUIS LE CAISSON DE L’ENCASTRABLE)

LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR UN MATÉRIAU NON COMBUSTIBLE 

S’ÉTENDANT SUR (E) 16 PO / 405MM À L’AVANT ET SUR (G) 8 PO / 205MM ENTRE LES CÔTÉS ET LA 

PORTE DE CHARGEMENT DU COMBUSTIBLE. PROLONGEMENT SUR 18 PO À L’AVANT AU CANADA.

ISOLATION THERMIQUE AVEC UNE VALEUR R = 1,4 À UNE DISTANCE DE 18 PO DEPUIS L’AVANT DE 

L’OUVERTURE DE LA PORTE AU CANADA  ET 16 PO AUX ÉTATS-UNIS. SI L’APPAREIL EST SURÉLEVÉ 

À 4,5 PO DU SOL, AUCUNE ISOLATION THERMIQUE N’EST REQUISE.

MUR LATÉRAL ADJACENT          A) 15 po / 380 mm

MANTEAU 

 

  B) 20 po / 510 mm

PAREMENT SUPÉRIEUR          C) 14 po / 355 mm

PAREMENT LATÉRAL  

  D) 0,5 po / 13 mm

D’INSTALLATION ET D’UTILISATION DU FABRICANT. À INSTALLER ET À UTILISER UNIQUEMENT DANS 

UN FOYER EN MAÇONNERIE OU UN FOYER PRÉFABRIQUÉ.

CONTACTEZ LES AUTORITÉS LOCALES EN BÂTIMENT OU INCENDIE POUR CONNAÎTRE LES  RE-

STRICTIONS D’INSTALLATION ET LES RÈGLES D’INSPECTION DANS VOTRE RÉGION.

920-131

531

CERTIFIÉ CONFORME AUX NORMES 2020 DU U.S. ENVIRONMENTAL PROTECTION AGENCY EN MATIÈRE 
D'ÉMISSION DE PARTICULES DE BOIS EN UTILISANT LE BOIS DE CORDE. HOMOLOGUÉ AVEC LA 
ASTM E3053. MODÈLE REGENCY I1150 –1.7 G /H. CET APPAREIL DE CHAUFFAGE AU BOIS DOIT ÊTRE 
INSPECTÉ PÉRIODIQUEMENT ET RÉPARÉ POUR FONCTIONNER CORRECTEMENT. CONSULTER LE 
MANUEL D’INSTALLATION POUR PLUS D’INFORMATION. LA RÉGLEMENTATION FÉDÉRALE INTERDIT 
DE FAIRE FONCTIONNER UN TEL APPAREIL SI LES CONSIGNES D’UTILISATION CONTENUES DANS LE 
PRÉSENT MANUEL NE SONT PAS RESPECTÉES.

0219WN027S

U.S. ENVIRONMENTAL PROTECTION AGENCY CERTIFIED TO COMPLY WITH 2020 PARTICULATE EMIS-
SION STANDARDS USING CORD WOOD.”  TESTED TO ASTM E3053.  MODEL REGENCY I1150 – 1.7G /HR. 
THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. CONSULT 
THE OWNER’S MANUAL FOR FURTHER INFORMATION. IT IS AGAINST FEDERAL REGULATIONS TO 
OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN 
THE OWNER’S MANUAL.

Copy of the I1150 Safety Decal

Summary of Contents for PROFIBUS I1150S

Page 1: ...t 03 10 21 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www...

Page 2: ...the building envelope It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual This heater is designed to burn natural wood onl...

Page 3: ...actory Built Fireplace 9 Altering the Fireplace 9 Draft 9 Installing Your Insert 10 Faceplate Trim Optional Bottom Faceplate Fan Support Installation 11 Fan Blower 15 Brick Installation 16 Baffle Inst...

Page 4: ...T PI CES OBLIGATOIRES POUR L INSTALLATION GAINE DE CHEMIN E HOMOLOGU E EN ACIER INOXYDABLE DE 5 5 PO 140mm ou 6 PO 152mm PI CE EN OPTION VENTILATEUR PI CE NO 172 917 CARACT RISTIQUES LECTRIQUES 115 VO...

Page 5: ...sert 5 dimensions 1 1 2 38mm With Standard Flue Adaptor 6 152mm Diameter STANDARD FLUE ADAPTOR Regency Inserts are designed to use either a 5 5 140mm or 6 152mm flue Measurement from back of faceplate...

Page 6: ...Insert dimensions 1 1 2 38mm 455 With Offset Flue Adaptor 6 152mm Diameter OFFSET FLUE ADAPTOR Regency Inserts are designed to use either a 5 5 140mm or 6 152mm flue Measurement from back of faceplate...

Page 7: ...r Canada measured from the fuel loading door Unit I1150 Adjacent Side Wall to Side A Mantel to Top of Unit B Top Facing to Top of Unit C Side Facing D Minimum Hearth Extension E Minimum Hearth Side Ex...

Page 8: ...naccessible once you have installed your Regency Insert you should either remove or secure it in the open position 6 Inspect your fireplace and chimney prior to installing your insert to determine tha...

Page 9: ...for any damage or flaws such as burnouts metal or refectory warping 3 Inspection to a minimum of NFPA 211 Level II is recommended All repairs must be made prior to installing an insert The fireplace...

Page 10: ...the rear of the unit into the fireplace See Diagram 3 En sure that the unit is centered in the existing fireplace and lined up with the flue adaptor 4 Slide the unit back until the flue adaptor is sli...

Page 11: ...Reproductive Harm www P65Warnings ca gov FACEPLATE TRIM FAN OPTIONAL BOTTOM FACEPLATE FAN SUPPORT INSTALLATION Regular Faceplate Dimensions shown with bottom faceplate fan support attached Oversize F...

Page 12: ...lder can then be slid into the tool bracket as shown Digital monitor operating door tool bracket Tool holder slid into tool bracket Tool holder Diagram 2A Rear View 4 Position the assembled faceplate...

Page 13: ...completed faceplate trim assembly to the insert Ensure to align the side faceplate slots with the hex bolts in the mounting brackets and tighten to secure in place Secure the Regency logo plate to the...

Page 14: ...screws See Diagram 9 Diagram 9 Rear Bottom View Note Fan not exactly as shown 18 Secure the bottom faceplate to the 3 sided faceplate using the 4 supplied bolts washers 19 Discard both side trims tha...

Page 15: ...sconnec tion when servicing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug f...

Page 16: ...tions Do not use a grate LyTherm sheet Order of firebrick install a Rear Firebrick b Firebox floor install brick over LyTherm Sheet c Right and left side Firebricks Fire bricks Size 1 4 1 4 x 7 2 4 1...

Page 17: ...ight base brick and right side wall brick 5 Install leftandrightbafflecoverplate installationofleftbaffleshownbelow Baffle Installation 4 Install the right and left side baffles right side baffle show...

Page 18: ...our glass by impact purchase your replacement from an authorized Regency dealer only Remove the door from the stove and remove the screws securing the glass retainer Position the glass in the door mak...

Page 19: ...a tight seal If door is too tight a washer can be removed Recheck door to ensure there is still a tight seal The handle should be approxi mately in the 8 o clock position when door is fully closed Dia...

Page 20: ...ff both bolts and slide deflector downward push deflector to the back wall of the unit and manoeuver out Install new deflector and hand tighten bolts Ensure positive location of the deflector prior to...

Page 21: ...may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many indicators as possible...

Page 22: ...Never build a roaring fire in a cold stove Always warm your stove up slowly 3 During the first few fires keep the combustion rate at a moderate level and avoid a large fire Only after 5 or 6 such fir...

Page 23: ...your stove 4 If you have smoke detectors prevent smoke spillage as this may set off a false alarm 5 Donotoverfireheater Ifthechimneyconnector flue baffle or the stove top begin to glow you are over fi...

Page 24: ...d before the burning season and as necessary during the season as creosote deposits may build up rapidly Moving parts of your stove require no lubrication 4 A small hot fire is preferable to a large s...

Page 25: ...into hole on left side air channel Align tab on right side air channel with notch on right hand end of air tube Firmly grip center of air tube with vise grips use hammer to tap vise grips from left to...

Page 26: ...r tubes vermiculite baffles see manual for details 2 Loosen the two 7 16 bolts nuts to remove replace vertical baffle 3 Repeat steps to install new vertical deflector NOTE ENSURE BAFFLE IS PUSHED UP A...

Page 27: ...e paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gasket Check and lubricate door hinge latch Use only high temperature anti...

Page 28: ...l Accent 12 846 306 Replacement Glass Includes Gasket Size 9 1 8 X 15 5 8 13 936 241 Replacement Glass Gasket Sold per foot 4 Feet required 14 846 570 Door Gasket Repair Kit 15 075 077F Glass Retainer...

Page 29: ...I1150 Regency Wood Insert 29 parts list Main Assembly 1 22 2 18 21 21 4 17 16 8 5 26 6 3 19 24 9 11 25 9 15 13 10 14 12 7 20 20 27...

Page 30: ...8 000 x 30 DEG BRICK 5 802 147 1 3 500 x 4 500 BRICK 4 802 152 2 2 000 x 9 000 BRICK 3 902 111 3 9 000 x 4 500 STANDARD BRICK 2 RD 14289 2 4 500 x 7 000 BRICK 1 RD 14288 2 4 250 x 7 000 BRICK Brick P...

Page 31: ...64 65 60 62 61 64 65 60 62 58 59 60 Faceplate Right Side Regular Oversize 61 Faceplate Left Side Regular Oversize 62 Faceplate Top Regular Oversize 64 Bottom 1 Piece Faceplate 65 Fan Support N S 171 5...

Page 32: ...1 Catalyst Combustor 10 Years Prorated Venting Chimney 1 Screens 1 See specific warranty details in regards to the catalyst combustor in unit manual Conditions Warranty protects against defect in manu...

Page 33: ...ct chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treat...

Page 34: ...the above limitations or exclusions may not apply to you Customers located outside the U S should consult their local provincial or national legal codes for additional terms which may be applicable t...

Page 35: ...for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Pr...

Page 36: ...36 I1150 Regency Wood Insert...

Page 37: ...I1150 Regency Wood Insert 37 notes...

Page 38: ...38 I1150 Regency Wood Insert notes...

Page 39: ...I1150 Regency Wood Insert 39...

Page 40: ..._____________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial _________...

Reviews: