Installing
Your Insert

SAFETY NOTE:

 The insert is very heavy and 

will require two or three people to move it into 
position. The insert can be made a little lighter 
by removing the cast iron door by opening it and 
lifting it off its hinges. Be sure to protect your 
hearth extension with a heavy blanket or carpet 
scrap during the installation.

NOTE: 

You will be required to purchase either 

the  standard  or  offset  6"  diameter  (152mm) 
flue adaptor that is best suited for the specific 
installation.

List of Tools needed;

 - Pull Rod (included with insert)

 - 1/2” socket / ratchet

 - 3/8 open face wrench 

1.  Install  flex  liner  into  existing  chimney  as 

per liner manufacturer’s specifications. See 
Diagram 1.

2.  Install the required flue adaptor onto the end 

of the flex liner.  Secure the adaptor using 
3 screws - 1 on the front, left and right side 
as shown in Diagram 2.

 

Alignment of the flue adaptor can be critical 
during the install, it is recommended that the 
flex liner be left as compressed as possible.  
Before inserting the unit the adaptor should 
hang, when level, slightly above the required 
height. 

Secure adaptor using 3 screws - 1 in the 

front and 1 each on the left and right side.

3.   Install the unit by first setting the rear of the 

unit into the fireplace. See Diagram 3. En-
sure that the unit is centered in the existing 
fireplace and lined up with the flue adaptor.

 

4.   Slide the unit back until the flue adaptor is 

slightly engaged.  

5.   At this point it is recommended to level the 

unit and ensure that the leveling bolts rest 
on the surface of the fireplace. This will keep 
the adaptor from binding as the unit is slid 
into position. 

6.   Insert  the  provided  pull  rod  through  the 

hole  in  the  top  center  of  the  unit.  Secure 
the threaded end into the flue adaptor as 
shown in Diagram 4. While sliding the unit 
into  place  pull  on  the  rod  to  ensure  that 
the flue adaptor is properly engaged. See 
Diagram 5. 

Pull Rod

7.   Ensure that the unit is still level. 

8.   To complete the installation and to ensure a 

secure fit and connection of the flue adaptor 
to the insert, it is essential that the two bolts, 
flat washers and lock washers (supplied with 
packaged manual) be installed and tightened 
using a 1/2" socket as shown in Diagram 6. 
This prevents the possibility of creosote drip 
and exhaust gas leakage.

9.   Remove the pull rod from the top center of 

the fireplace. See Diagram 7.

10.  Re-install  the  door  if  removed  prior  to 

installation.

NOTE: The pull rod should not be thrown 

away. It should be kept if the stove 
is ever needed to be removed 
from the fireplace.

Flex Liner

Pull Rod In Place

Pull Rod

Diagram 1

Diagram 2

Diagram 3

Diagram 4

Diagram 5

Diagram 6

Diagram 7

Flue Adaptor

Summary of Contents for PROFIBUS I1150S

Page 1: ...t 03 10 21 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www...

Page 2: ...the building envelope It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual This heater is designed to burn natural wood onl...

Page 3: ...actory Built Fireplace 9 Altering the Fireplace 9 Draft 9 Installing Your Insert 10 Faceplate Trim Optional Bottom Faceplate Fan Support Installation 11 Fan Blower 15 Brick Installation 16 Baffle Inst...

Page 4: ...T PI CES OBLIGATOIRES POUR L INSTALLATION GAINE DE CHEMIN E HOMOLOGU E EN ACIER INOXYDABLE DE 5 5 PO 140mm ou 6 PO 152mm PI CE EN OPTION VENTILATEUR PI CE NO 172 917 CARACT RISTIQUES LECTRIQUES 115 VO...

Page 5: ...sert 5 dimensions 1 1 2 38mm With Standard Flue Adaptor 6 152mm Diameter STANDARD FLUE ADAPTOR Regency Inserts are designed to use either a 5 5 140mm or 6 152mm flue Measurement from back of faceplate...

Page 6: ...Insert dimensions 1 1 2 38mm 455 With Offset Flue Adaptor 6 152mm Diameter OFFSET FLUE ADAPTOR Regency Inserts are designed to use either a 5 5 140mm or 6 152mm flue Measurement from back of faceplate...

Page 7: ...r Canada measured from the fuel loading door Unit I1150 Adjacent Side Wall to Side A Mantel to Top of Unit B Top Facing to Top of Unit C Side Facing D Minimum Hearth Extension E Minimum Hearth Side Ex...

Page 8: ...naccessible once you have installed your Regency Insert you should either remove or secure it in the open position 6 Inspect your fireplace and chimney prior to installing your insert to determine tha...

Page 9: ...for any damage or flaws such as burnouts metal or refectory warping 3 Inspection to a minimum of NFPA 211 Level II is recommended All repairs must be made prior to installing an insert The fireplace...

Page 10: ...the rear of the unit into the fireplace See Diagram 3 En sure that the unit is centered in the existing fireplace and lined up with the flue adaptor 4 Slide the unit back until the flue adaptor is sli...

Page 11: ...Reproductive Harm www P65Warnings ca gov FACEPLATE TRIM FAN OPTIONAL BOTTOM FACEPLATE FAN SUPPORT INSTALLATION Regular Faceplate Dimensions shown with bottom faceplate fan support attached Oversize F...

Page 12: ...lder can then be slid into the tool bracket as shown Digital monitor operating door tool bracket Tool holder slid into tool bracket Tool holder Diagram 2A Rear View 4 Position the assembled faceplate...

Page 13: ...completed faceplate trim assembly to the insert Ensure to align the side faceplate slots with the hex bolts in the mounting brackets and tighten to secure in place Secure the Regency logo plate to the...

Page 14: ...screws See Diagram 9 Diagram 9 Rear Bottom View Note Fan not exactly as shown 18 Secure the bottom faceplate to the 3 sided faceplate using the 4 supplied bolts washers 19 Discard both side trims tha...

Page 15: ...sconnec tion when servicing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug f...

Page 16: ...tions Do not use a grate LyTherm sheet Order of firebrick install a Rear Firebrick b Firebox floor install brick over LyTherm Sheet c Right and left side Firebricks Fire bricks Size 1 4 1 4 x 7 2 4 1...

Page 17: ...ight base brick and right side wall brick 5 Install leftandrightbafflecoverplate installationofleftbaffleshownbelow Baffle Installation 4 Install the right and left side baffles right side baffle show...

Page 18: ...our glass by impact purchase your replacement from an authorized Regency dealer only Remove the door from the stove and remove the screws securing the glass retainer Position the glass in the door mak...

Page 19: ...a tight seal If door is too tight a washer can be removed Recheck door to ensure there is still a tight seal The handle should be approxi mately in the 8 o clock position when door is fully closed Dia...

Page 20: ...ff both bolts and slide deflector downward push deflector to the back wall of the unit and manoeuver out Install new deflector and hand tighten bolts Ensure positive location of the deflector prior to...

Page 21: ...may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many indicators as possible...

Page 22: ...Never build a roaring fire in a cold stove Always warm your stove up slowly 3 During the first few fires keep the combustion rate at a moderate level and avoid a large fire Only after 5 or 6 such fir...

Page 23: ...your stove 4 If you have smoke detectors prevent smoke spillage as this may set off a false alarm 5 Donotoverfireheater Ifthechimneyconnector flue baffle or the stove top begin to glow you are over fi...

Page 24: ...d before the burning season and as necessary during the season as creosote deposits may build up rapidly Moving parts of your stove require no lubrication 4 A small hot fire is preferable to a large s...

Page 25: ...into hole on left side air channel Align tab on right side air channel with notch on right hand end of air tube Firmly grip center of air tube with vise grips use hammer to tap vise grips from left to...

Page 26: ...r tubes vermiculite baffles see manual for details 2 Loosen the two 7 16 bolts nuts to remove replace vertical baffle 3 Repeat steps to install new vertical deflector NOTE ENSURE BAFFLE IS PUSHED UP A...

Page 27: ...e paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gasket Check and lubricate door hinge latch Use only high temperature anti...

Page 28: ...l Accent 12 846 306 Replacement Glass Includes Gasket Size 9 1 8 X 15 5 8 13 936 241 Replacement Glass Gasket Sold per foot 4 Feet required 14 846 570 Door Gasket Repair Kit 15 075 077F Glass Retainer...

Page 29: ...I1150 Regency Wood Insert 29 parts list Main Assembly 1 22 2 18 21 21 4 17 16 8 5 26 6 3 19 24 9 11 25 9 15 13 10 14 12 7 20 20 27...

Page 30: ...8 000 x 30 DEG BRICK 5 802 147 1 3 500 x 4 500 BRICK 4 802 152 2 2 000 x 9 000 BRICK 3 902 111 3 9 000 x 4 500 STANDARD BRICK 2 RD 14289 2 4 500 x 7 000 BRICK 1 RD 14288 2 4 250 x 7 000 BRICK Brick P...

Page 31: ...64 65 60 62 61 64 65 60 62 58 59 60 Faceplate Right Side Regular Oversize 61 Faceplate Left Side Regular Oversize 62 Faceplate Top Regular Oversize 64 Bottom 1 Piece Faceplate 65 Fan Support N S 171 5...

Page 32: ...1 Catalyst Combustor 10 Years Prorated Venting Chimney 1 Screens 1 See specific warranty details in regards to the catalyst combustor in unit manual Conditions Warranty protects against defect in manu...

Page 33: ...ct chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treat...

Page 34: ...the above limitations or exclusions may not apply to you Customers located outside the U S should consult their local provincial or national legal codes for additional terms which may be applicable t...

Page 35: ...for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Pr...

Page 36: ...36 I1150 Regency Wood Insert...

Page 37: ...I1150 Regency Wood Insert 37 notes...

Page 38: ...38 I1150 Regency Wood Insert notes...

Page 39: ...I1150 Regency Wood Insert 39...

Page 40: ..._____________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial _________...

Reviews: