safety decal
This is a copy of the label that accompanies each HZ33CE Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.
NOTE: Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas fitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible con-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
507
507
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
NATURAL GAS:
Model HZ33CE-NG11
PROPANE:
Model HZ33CE-LP11
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
DOOR SEAL: Please check that
the door is properly sealed
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Minimum Clearances to Combustibles
Dégagements minimaux par rapport aux matériaux combustibles
0" Clearance to
combustibles from:
Sides, bottom and rear of unit
*Top - 3-1/2" (89mm) non-combustible
material required above unit.
Ceiling Clearances from
Top Opening of Unit:
(A) 30" (762mm)
Side Wall Clearance from
Side Opening of Unit:
B) 9"(229mm)
Floor Clearance:
C) 0”
Alcove Clearances
D) Min. Width 84" (1219mm)
E) Max. Depth 36" (914mm)
(
See Instruction Manual for Detailed Instructions)
Serial No./ No de serie
APPAREIL FONCTIONNANT AU GAZ NATUREL
Modèle
HZ33CE-NG11
Pression d'alimentation minimale
Pression manifold lev e
é é
Pression manifold basse
Taille de l’orifice
D bit calorifique minimal
é
D bit calorifique maximal
é
Altitude
APPAREIL FONCTIONNANT AU PROPANE
Modèle HZ33CE-LP11
Pression d'alimentation minimale
Pression manifold lev e
é é
Pression manifold basse
Taille de l’orifice
D bit calorifique minimal
é
D bit Calorifique maximal
é
Altitude
Model/Modèle:
HZ33CE-NG11
Model/Modèle:
HZ33CE-LP11
Made in Canada / Fabriqué au Canada
Part #: 920-012
Colour: Black on silver, except for items indicated red.
Size: 9.096” W x 6.074” H (file at 100%)
Material: 2 ml silver matt polyester (DPM SMS)
Jan 02/19: Created draft
*
Printer
: Start number sequence at 507000001
Duplicate S/N
11" WC(2.73 kPa)
10" WC(2.49 kPa)
6.4" WC(1.59 kPa)
# 56 DMS
12,500 Btu/h (3.66 kW)
15,000 Btu/h (4.39 kW)
0-4500 ft/pi (0-1372 m)
5" WC(1.25 kPa)
3.5" WC(0.87 kPa)
1.6" WC(0.39 kPa)
# 47 DMS
12,000 Btu/h (3.51 kW)
17,000 Btu/h (4.98 kW)
0-4500 ft/pi (0-1372 m)
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details.
Fan (Part # 438-917)
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard.
Si ces normes ne sont pas pertinentes, utiliser la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les
règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
lectrical supply / Alimentation électrique 115VAC, 1.13 A, 60Hz.
For use with glass doors certified with the appliance only À utiliser uniquement avec les portes en verre certifiées avec l'appareil
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
FOYER AU GAZ À ÉVACUATION -
A
Floor
Wall
Ceiling
C
For Use Only with Barrier (Part # 438-513) Follow installation instructions. Utiliser uniquement avec l’écran ( n ° 438-513) Suivre les instructions d'installation.
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Listed/Nom:
VENTED GAS FIREPLACE HEATERS /
APPAREIL DE CHAUFFAGE AU GAZ À ÉVACUATION.
Certified to/Certifi :
é
ANSI Z21.88-2017 • CSA-2.33-2017
CSA 2.17-2017
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.
C #: 4001172
For use only with barrier (Part # 437-024)
Pour l'utilisation seulement avec la
920-012
CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1
Natural Gas / Gaz naturel 64.67%
Propane Gas / Gaz propane 64.17%
CANADIAN ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169