8
Regency GF900C-2 Gas Fireplace
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may
NOT be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance
that this fireplace and vent system be installed only in accordance with these instructions.
Clearance:
Dimension
Measured From:
A: Mantel Height (min.)
191mm
Top of Fireplace Opening (Hot Air Outlet)
B: Sidewall (on one side)
146mm
Side of Fireplace Opening
C: Ceiling
(room and/or alcove)
1003mm
Top of Fireplace Opening
D: Mantel Depth (max.)
305mm
420mm Above Fireplace Opening
E: Alcove Width
1480mm
Sidewall to Sidewall (Minimum)
F: Alcove Depth
787mm
Front to Back Wall (Maximum)
G: From Floor
605mm
Top of Fireplace Opening (Hot Air Outlet)
Note:
0
No hearth required
Installed close
to ceiling.
Flue Clearances to Combustibles
Horizontal - Top
76mm
Horizontal - Side
51mm
Horizontal - Bottom
51mm
Vertical
51mm
Alcove
E
F
F
E
D
A
B
Installed Close
to Floor
G
IMPORTANT: If installing a television above
this appliance, the television must be either
fully recessed into the wall above the
fireplace and or have a mantle below the
television. If the television is left unprotected,
the extreme heat being emitted from this
appliance will result in damage to the
television. See clearance requirements for
both mantle and or enclosing the top of the
appliance in this manual.
installation
NOTE:
The unit can be installed onto a combustible base.