Regency GF900C-2 Gas Fireplace
15
installation
NON COMBUSTIBLE REQUIREMENTS
FLUSHED FINISHING & FRAMING WITH NON-COMBUSTIBLE MATERIAL
Note:
For flush finishing, the top nailing strip must be removed and a non-
combustible steel stud support added.
The seven fireplace opening standoffs which are located on this unit can
be removed when non combustible material is installed flush with the unit.
(see P. 13).
Non-combustible finishing material on the top and sides must also be used.
NOTE:
The appliance must be installed on
a flat, solid, continuous surface For
example a wood, metal or concrete
floor. In a raised (on the wall) ap-
plication the appliance must be
installed on a metal or wood panel
extending the full width and depth
of the appliance.
796mm
605mm
1165mm
Non-combustible
Combustible
Combustible
Steel Stud
on edge
Timber Stud
Timber Stud
159mm
446mm
Non-Combustible
Material
Combustible
Material
Finished
Material
* diagrams shown below are
with top nailing strip removed.
12mm
25mm
38mm
Unit
Unit
Unit
MINIMUM THICKNESS OF THE FINISH MATERIAL: 12MM
A minimum thickness of 12mm non-
combustible facing is required.