2    |  GF40-2 Pellet Stove

CLEARANCES TO COMBUSTIBLES

IMPORTANT:

 The GF40-2 must have a Hearth Pad when installing the unit on a combustible floor. The included hearth pad meet all the 

requirement of a proper hearth pad. If you do not use the included hearth pad a certified non combustible Hearth Pad with a minimum R Value of 

at least 0.84 must be placed underneath the unit and extend six inches in front of the unit measured from the glass. If the GF40-2 is installed on 

carpet the use of a solid non combustible Hearth Pad must be used under leveling legs.

These dimensions are minimum clearances but it is recommended 

that you ensure sufficient room for servicing, routine cleaning and 

maintenance.

A. Side wall to unit   

 

 8 inches    (200 mm)

B. Back wall to unit 

 

 5.5 inches  (140 mm)

C. Back wall to Chimney Connector       4  inches (100 mm)
D. Corner to unit 

 

 3 inches    (75 mm)

E. Glass to Hearth Pad              

 6 inches    (150 mm)

The unit may be installed in an alcove if desired. These minimum 

clearances to combustibles must be maintained at all times. Be sure 

to leave room for servicing, routine cleaning, and maintenance. These 

are inside dimensions.

Minimum Alcove Width      36 inches  (915 mm)
Minimum Alcove Height    48 inches  (1220 mm)
Minimum Alcove Depth     30 inches (762 mm)

ALCOVE CLEARANCES

Figure 1 - Minimum Install Clearances

Figure 2 - Minimum Alcove Clearances

Summary of Contents for Greenfire GF40-2

Page 1: ...mption will vary with the type of fuel used Model GF40 2 Heat Output BTUs 6 881 23 892 BTUs Emissions grams hr EPA Certified 0 54 grams hr Efficiency EPA HHV 80 2 Efficiency EPA LHV 87 4 Flue Size 3 7...

Page 2: ...se dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing routine cleaning and maintenance A Side wall to unit 8 inches 200 mm B Back wall to unit 5 5 in...

Page 3: ...ond the control of FPI we grant no guarantee against such incidents NOTE Venting terminals shall not be recessed into walls or siding Letter Minimum Clearance Description A 24 in 61 cm Above grass top...

Page 4: ...eople sleep in Outside fresh air is mandatory Secure outside air connections directly to fresh air intake pipe and secure with three screws evenly spaced CAUTION THE STRUCTURAL INTEGRITY OF THE MANUFA...

Page 5: ...ble with high temperature silicone 9 The pipe must extend at least 12 30 cm away from the building If necessary bring another length of pipe PL type to the outside of the home to connect to the first...

Page 6: ...allation to use if there is a concrete or retaining wall in line with exhaust vent on a pellet stove The termination must be 12 30 cm from the outside wall and 12 30 cm above the ground Figure 1 Venti...

Page 7: ...apor barrier 6 Finally extend the pellet vent to go through the roof flashing 7 Ensure that the rain cap is approximately 24 600 mm above the roof 1 Install a tee with clean out on the outside of the...

Page 8: ...e chimney Freestanding Hearth Mount Installation Combustible Floor Masonry Fireplace Rain Cap Steel Plate or Flashing Flexible or Rigid 6 Stainless Steel Liner 10 25 4 cm Mantel Minimum 8 20 cm from t...

Reviews: