GF40-2 Pellet Stove  |    1

Greenfire GF40-2 Freestanding Pellet Stove

Weight (with full hopper): 280 lb (127 Kg)
Hopper Capacity: up to 67 lb (28 Kg)
Voltage: 110 - 120 V
Max Current: 4.1 Amps
Consumption on High: 3.1 lb/hr (1.4 Kg/hr)*
Consumption on Low: 1.3 lb/hr (0.6 Kg/hr)*
(Note: Consumption will vary with the type of fuel used.)

Model

GF40-2

Heat Output BTUs

6,881 - 23,892 BTUs

Emissions (grams/hr) EPA Certified

0.54 grams/hr 

Efficiency (EPA HHV)*/**

80.2%

Efficiency (EPA LHV)**

87.4%

Flue Size

3" (76mm)

US Biomass Tax Rebate Eligible**

Yes

*US Biomass Tax Rebate eligibility is based on the HHV value being 

greater than or equal to 75%.

**When using optional top vent adaptor kit (GF40-920) and 3’’ to 6’’ 

flue adptor (3PVP-X6). See manual for further information.

UNIT DIMENSIONS 

Summary of Contents for Greenfire GF40-2

Page 1: ...mption will vary with the type of fuel used Model GF40 2 Heat Output BTUs 6 881 23 892 BTUs Emissions grams hr EPA Certified 0 54 grams hr Efficiency EPA HHV 80 2 Efficiency EPA LHV 87 4 Flue Size 3 7...

Page 2: ...se dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing routine cleaning and maintenance A Side wall to unit 8 inches 200 mm B Back wall to unit 5 5 in...

Page 3: ...ond the control of FPI we grant no guarantee against such incidents NOTE Venting terminals shall not be recessed into walls or siding Letter Minimum Clearance Description A 24 in 61 cm Above grass top...

Page 4: ...eople sleep in Outside fresh air is mandatory Secure outside air connections directly to fresh air intake pipe and secure with three screws evenly spaced CAUTION THE STRUCTURAL INTEGRITY OF THE MANUFA...

Page 5: ...ble with high temperature silicone 9 The pipe must extend at least 12 30 cm away from the building If necessary bring another length of pipe PL type to the outside of the home to connect to the first...

Page 6: ...allation to use if there is a concrete or retaining wall in line with exhaust vent on a pellet stove The termination must be 12 30 cm from the outside wall and 12 30 cm above the ground Figure 1 Venti...

Page 7: ...apor barrier 6 Finally extend the pellet vent to go through the roof flashing 7 Ensure that the rain cap is approximately 24 600 mm above the roof 1 Install a tee with clean out on the outside of the...

Page 8: ...e chimney Freestanding Hearth Mount Installation Combustible Floor Masonry Fireplace Rain Cap Steel Plate or Flashing Flexible or Rigid 6 Stainless Steel Liner 10 25 4 cm Mantel Minimum 8 20 cm from t...