installation
52 | Grandview
®
G800C-1 Gas Fireplace
•
Vent must be supported at offsets.
• Firestops are required at each floor level and whenever passing through a wall.
• Maintain clearances to combustibles.
Note:
Must use optional rigid pipe adaptor when using rigid vent systems (Part # 510-994).
Venting Arrangements - Vertical Termination - Rigid Pipe System and Vertical Flex Kit to Same
Limitations
(Propane & Natural Gas)
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90
o
elbows, with rigid pipe
vent systems for Propane and Natural Gas.
22
66
1100
44
88
1122
Vertical Height (Feet)
Horizontal (Feet)
88
1100
1122
1144
1166
1188
2200
2222
2244
2266
2288
3300
3322
3344
3366
3388
00
22
44
66
Minimum
Height
Requirement
44" (1118mm)
Set #3 (1-1/4" open)
Set #2 (1-3/4" open)
Set #1 (2" open)
00
CPI mode
recommended