background image

 

E33-10 FPI Direct Vent Gas Insert

  |     

5

 

                                                                                                                                |

5

safety decal

This is a copy of the labels that accompany each E33 Gas Insert. We have printed a copy of the contents here for your review. The safety label is located 

on a plate inside the base of the unit visible when the bottom louver is opened. Ensure that the safety label is attached to the unit.

NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Fan Part No. 910-331/P

ELECTRICAL SUPPLY/ALIMENTATION ELECTRIQUE:

115V60HZ less than/Moins de 2 AMP.

NOT FOR USE WITH SOLID FUEL/ NE PAS UTILISER

AVEC DU COMBUSTIBLE SOLIDE.

Minimum Clearances to Combustibles from Insert

Side Walls

*A

8"

(203mm)

Ceiling

B

47"

(1194mm)

Min. Mantel Height

C

15"

(381mm)

Max. Mantel Depth

D

3½"

(89mm)

D

E

F

H

G

A

B

C

I

MADE IN CANADA /FABRIQUE AU CANADA

Mantel Clearances

DO NOT REMOVE THIS LABEL /

NE PAS ENLEVER CETTE ETIQUETTE

Serial No. / No de serie

Duplicate Serial number

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and
Propane Installation Code, CSA B149.1.

This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not
applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard
for Recreational Vehicles

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner's manual for details.

W

:

ARNING This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original

parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel
Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part
3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA
501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.

AVERTISSEMENT: Ce foyer a été converti pour utilisation avec un foyer au gaz encastrable et ne peut être utiliser pour brûler du bois ou d'autres
combustibles solides à moins que toutes les pièces d'origine aient été remplacées et que le foyer ait été approuvé de nouveau par l'autorité compétente.

This vented gas fireplace heater is not for use with air filters.

Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.

For use with glass doors certified with the appliance only

Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil

VENTED GAS FIREPLACE HEATER -

FOYER AU

NOT FOR USE WITH SOLID FUELS. /

GAZ À ÉVACUATION - NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.

É

É

QUIP A L'UISINE POUR GAZ PROPANE

É

É

QUIP A L'UISINE POUR GAZ NATURAL

FPI Fireplace Products International Ltd.,

Delta BC, CANADA

Pression d'allimentation minimum
Pression

la tubulure d' chappement basse

à

é

Pression

la tubulure d' chappement lev e

à

é

é

é

Dimensions de l'orifice
D bit Calorifique minimum

é

D bit Calorifique maximum

é

Pression d'allimentation minimum
Pression

la tubulure d' chappement basse

à

é

Pression

la tubulure d' chappement lev e

à

é

é

é

Dimensions de l'orifice
D bit Calorifique minimum

é

D bit Calorifique maximum

é

298

298

Model/Modele:

E33-NG1

0

919-378

Model/Modele:

E33-LP1

0

NATURAL GAS FIREPLACE INSERT: MODEL

E33-NG10

Factory Equipped For Altitude 0-4500ft. (0-1370m)

Min. Supply Pressure

5“

WC

(1.25 kpa)

Low Setting Man. Pressure

1.1"

WC

(0.27 kpa)

Max. Manifold Pressure

3.8"

WC

(0.95 kpa)

Orifice Size

31

DMS

Minimum Input

20,000

Btu/h

(5.86 kW)

Maximum Input

38,000

Btu/h

(11.13 kW)

PROPANE GAS FIREPLACE INSERT: MODEL

E33-LP10

Factory Equipped For Altitude 0-4500ft. (0-1370m)

Min. Supply Pressure

12"

WC

(2.99 kpa)

Low Setting Man. Pressure

2.9"

WC

(0.72 kpa)

Max. Manifold Pressure

11"

WC

(2.74 kpa)

Orifice Size

50

DMS

Minimum Input

19,000

Btu/h (5.56 kW)

Maximum Input

35,500

Btu/h (10.4 kW)

Alcove Width

E

76"

(1930mm)

Alcove Depth

F

36"

(914mm)

Non-Combustible Hearth Extension

Hearth Height

G

1-1/4"

(32mm)

Hearth Width

H

45-1/2"

(1156mm)

Hearth Depth

I

13"

(330mm)

* Alcove side wall must have a

min. of 8” clearance on one side.

4001172

For Use Only with Barrier (Part # 342-013) Follow installation instructions.

Utiliser uniquement avec l’écran ( n ° 342-013) Suivre les instructions d'installation.

Listed: VENTED GAS FIREPLACE HEATER
/ FOYER AU GAZ À ÉVACUATION

CANADA and U.S.A.

Certified for/Certifi e pour:

é

Certified to:

CAN/CGA-2.17-M91(R2009)

Tested

:

to ANSI Z21.88-20

CSA 2.33-20

14 &

14

Summary of Contents for E33-LP10

Page 1: ...d liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach you gas supplier call the fire department Installation and...

Page 2: ...he warmth and charm of a fireplace at the flick of a switch The E33 NG10 and E33 LP10 have been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency ...

Page 3: ... 3 dimensions 28 11 16 42 7 16 26 3 4 16 1 4 23 3 4 11 1 16 22 3 4 46 1 2 1181mm 1078mm 679mm 729mm 281mm 413mm 603mm 578mm 3 1 4 1 3 4 83mm 44mm 32 1 4 819mm 24 1 2 622mm optional spacer Oversized Faceplate Dimensions 49 9 16 x 33 1 8 H ...

Page 4: ...29 Valve Description 12 DC Spark Igniter Battery Installation 12 Optional Brick Panel 12 Log Set Installation 14 Conversion from NG to LP 17 Low profile Faceplate Installation 18 Optional Backing Plate Installation 20 Safety Screen Installation 21 Standard Flush Door 21 Wiring Diagram 22 First Fire 23 Operating Instructions 23 Lighting Procedure 23 Shutdown Procedure 23 DC Spark Igniter Battery In...

Page 5: ...ec le type de gaz indiqué sur la plaque signalétique Cet appareil peut être installé dans une maison préfabriquée ou mobile É U seulement installée à demeure si les règlements locaux le permettent Voir la notice de l utilisateur pour plus de renseignements Cet appareil ne peut pas être utilisé avec d autres gaz sauf si une trousse de conversion certifiée est fournie AVERTISSEMENT Ce foyer a été co...

Page 6: ...ly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspectio...

Page 7: ...combustion and ventilation air Follow instructions and information in CAN CGAB149 in Canada or the National Fuel Gas Code ANSI Z223 1 in the USA regarding requirements for combustion and ventilation air CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ESPE CIALLY THE FIREPLACE GLASS ...

Page 8: ...stemensurethatthedamper plateisopenandsecuretopreventthedamperplate from falling down and crushing the liner The Regency Gas Insert is installed as listed below 1 Check all clearances to combustibles Refer to the following sections where applicable a Minimum Clearances to Combustibles b Regency Flush Combustible Mantel Clearances c Mantel Clearances 2 Make the gas connection Refer to the Gas Conne...

Page 9: ...ION SYSTEM The air shutter can be adjusted by moving the adjusting wire up or down The wire is accessed through the bottom louver opening Open the air shutter for a blue flame or close for a yellower flame The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude Minimum Air Shutter Opening 5 16 Natural Gas 7 16 Propane CAUTION Carbon will be produced...

Page 10: ...pth I 13 330 mm Alcove side wall must have a min of 8 clearance on one side COMBUSTIBLE MANTEL CLEARANCES Because of the extreme heat this fireplace emits the mantel clear ances are critical Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Mantel can be installed anywhere in shaded area or higher using the a...

Page 11: ...e and screws may be used instead of gear clamps at connections of liner to inlet and vent collars THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE GAS CONNECTION WARNING Only persons licensed to work with gas piping may make the necessary gas connections to this appliance VENTING This appliance is designed to be attached to two 3 76mm co linear ...

Page 12: ...eter to IN and or OUT pressure tap s using a 5 16 ID hose 4 Lightthepilotandturnthevalveto ON position 5 The pressure check should be carried out with theunitburningandthesettingshouldbewithin the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but...

Page 13: ...ottom Clips Top Bracket 5 Place the top bracket onto the top edge of the top panel refer to Diagram 2 Diagram 2 6 Slide the top panel and bracket assembly carefully onto the baffle plate ensuring the panel is centered Make sure the tabs of the topbracketfitintothebaffleopenings refer to Diagram 3 7 Insert the back panel by sliding it between the sidewalls of the firebox and the rear log support Di...

Page 14: ...lease handle with care and do not force them into position to avoid chipping 3 Remove the grate by removing the two Phillips screws Slide the grate outwards to remove it from the unit refer to Diagram 1 Diagram 1 2 Remove the safety screen and glass door if al ready installed Page 1 of 3 4 Angle log 03 17 and slide it between the top and bottom burner tube under the T section until it touches the ...

Page 15: ...nto the groove and gently place into position until it touches the locating tab see Diagram 6 7 Locating Tab 03 20 Locating Pin Diagram 6 Diagram 7 03 23 03 20 03 17 03 21 9 Place log 03 22 over log 03 23 and log 03 20 Ensure the pin hole of log 03 22 lines up with the left pin of log 03 23 as well as the left pin of log 03 20 refer to Diagram 8 03 22 Locating Pins 03 23 03 20 Diagram 8 10 Place l...

Page 16: ...ensuring the pin hole of log 03 24 lines up with the right pin of log 03 23 and the right pin of log 03 21 refer to Diagram 11 03 24 03 23 03 21 Locating Pins Diagram 11 12 Place log 03 19 over the left center of the grate Ensure the log set looks like Diagram 12 Diagram 12 03 19 Page 3 of 3 13 Separate platinum embers and place at the front of the burner Avoid stacking platinum embers ...

Page 17: ...0 Remove NG stepper motor by removing 3 screws in locations shown below replace with LP stepper motor secure in place with 3 screws E33 10 Conversion from NG to LP for E33 10 using SIT 829 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION 4 Remove front base brick Installation of LP Conversion Kit Installer Notice These instructions must be...

Page 18: ... black and red fan switch wires in the black casing to the wire connectors from the fan speed control 5 Secure the wires to the back of the inner faceplate with a wire clip 6 Install lower trim to unit with 2 screws on each side as shown in Diagram 7 NOTE Diagram shown without faceplate backing installed to better illustrate location of holes 3 Tuck the wires into the clip to keep them away from t...

Page 19: ...h the slots on the faceplate backing hook outer faceplate on to slots and lower to install Outer faceplate Back faceplate Slot brackets Final Install 9 Attach the bottom louver to the 2 hinges using 3 screws per hinge Diagram 9 8 Attach the 2 bottom louver hinges to the bottom flange on the firebox using 2 screws per hinge Diagram 8 11 Hook screen door over glass frame Diagram 10 Diagram 12 ...

Page 20: ...crews are also required to secure the top section of the spacer only 3 Proceed to faceplate installation see faceplate instructions in manual or with faceplate 2 Install the custom backing plate to the faceplate backing and spacer with 9 screws 3 on each side and 3 across the top installed from the backside of the backing plate into the backside of the assembled faceplate backing with spacer as sh...

Page 21: ... unit Refer to Diagram 3 STANDARD FLUSH DOOR SAFETY SCREEN INSTALLATION Diagram 2 Screws Diagram 1 1 To remove safety screen flip open bottom louver and remove 2 screws in locations shown below 2 Pull off safety screen and frame from glass door 3 To install reverse Steps 2 1 To remove the flush door reverse the above steps NOTE The chain must rest on TOP of the gas inlet pipe never under it Diagra...

Page 22: ...cle Do not cut or remove the grounding prong from this plug Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation ENGLISH REMOTE TP TH TPTH Green White Red Black 9 Ground Neutral Live Black Black Red Minimum Convection Air Temp Switch O...

Page 23: ...gain without a minimum of a 60 second wait 9 Hookupremotereceivertowiremarked receiver which will be located on the bottom of the appli ance This remote control requires coding See remote control instructions for details NOTE This appliance will operate during power outages Onlythefanwillnotoperateuntilpower is restored If the remote batteries in both the handheldtransmitterorreceiverlosepower the...

Page 24: ...l eau même partiellement Faites inspecter l appareil par un tech nicien qualifié et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l eau DO NOT REMOVE THIS INSTRUCTION PLATE TO TURN OFF GAS APPLIANCE This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 or Natural Gas and Propan...

Page 25: ...notusethisapplianceifanyparthasbeen under water Immediately call a qualified service technician to inspect the appliance andtoreplacenaypartofthecontrolsystem and any gas control which has been under water 8 Periodically check the pilot flames Correct flamepatternhasthreestrongblueflames 1 flowingaroundthethermopileand1around the thermocouple and 1 flowing across the front of the burner Note Ifyou...

Page 26: ...iance with glass panels removed cracked or broken Replacement of the glass should be done by a licensed or qualified service person Flush Glass Replacement Remove the flush door front refer to the Standard Flush Door section Remove the 4 glass clips from each corner Slide in the new replacement glass Push the 4 glass clips back onto the frame To Remove Fan 1 Turn the unit off and allow it to cool ...

Page 27: ... fan 15 Reverse above steps Sealfanaccesspanelusinghightemperature silicone sparingly 13 Pull Fan Assembly forward to disengage the fan clip on the rear wall Then lift the Fan Assembly up and pull through firebox opening 14 Disconnect green wire from power cord 1 Turn the unit off and allow it to cool down to room temperature 2 Unplug or disconnect power source 3 Shut off the main gas supply 4 Rem...

Page 28: ...te 17 Wire Holder Clip 18 Strain Relief 19 Grommet for Power Cord 20 342 010 Door Trim 21 342 013 Mesh 22 342 012 ScreenFrame 23 342 011 Bottom Inside Frame 340 901 Brick Panel Set Standard Brown 340 902 Brick Panel Set Standard Red 33 Brick Panel Right 34 Brick Panel Left 35 Brick Panel Back 36 37 340 094 Brick Clip 340 043 Trim Brick Front 340 528 Base Brick Panel 3pc 43 Stove Top 45 Adaptor Sto...

Page 29: ... 50 LP 936 170 Orifice Gasket 68 W840470 Pilot assembly gasket 910 386 Thermocouple 910 341 Thermopile 910 432 Pilot Tube 910 096 Pilot Hood 3 way 910 030 Electrode 910 036 Pilot Orifice NG 910 037 Pilot Orifice LP 79 948 433 Burner Assy NG LP 82 340 047 Burner Grate 910 572 Remote Receiver 910 592 Remote Transmitter 911 127 Receiver compartment door 911 164 Valve Remote wiring harness 342 969 Con...

Page 30: ...30 E33 10 FPI Direct Vent Gas Insert 30 parts list LOW PROFILE FACEPLATE Part Description 1 342 924 Low Profile Faceplate 342 928 Oversize Low Profile Faceplate 2 342 958 Custom Backing Plate 1 2 ...

Page 31: ...istributor or agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement parts and issue cre...

Page 32: ...___________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your register...