Regency
®
E18E-11 Gas Fireplace Insert
| 5
safety decal
This is a copy of the label that accompanies each Regency
®
Gas Insert. We have
printed a copy of the contents here for your review. The safety label is located on the
front inside base of the unit visible when the bottom louver is open.
Note: Regency
®
units are constantly being improved. Check the label on the
unit and if there is a difference, the label on the unit is the correct one.
Please note that with the addition of thermostat control and outside
combustion air supply, this unit is approved for bedroom installations.
For the State of Massachusetts, installation and repair must be done by a plumber
or gasfitter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches
in length.
For the State of Massachusetts, the appliances individual manual shut-off must
be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm
in accordance with NFPA 720 and a CO alarm with battery back up in the same
room where the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
Serial No. / No de série
500
500
Min. supply pressure
5"
WC
(1.25kPa)
Low Setting Man. pressure 1.6" WC
(0.40kPa)
Max. Manifold pressure
3.5" WC
(0.87kPa)
Orifice size
44
DMS
(2.64mm)
Minimum input
15,000 Btu/h
(4.40kW)
Altitude
0-4500ft
(0-610m)
Maximum input
21,600 Btu/h
(6.33kW)
NATURAL GAS FIREPLACE INSERT: MODEL E18E-NG11
PROPANE FIREPLACE INSERT: MODEL E18E-LP11
11"
WC
(2.74 kPa)
6.4"
WC
(1.59 kPa)
10"
WC
(2.49 kPa)
55
DMS
(1.6mm)
17,000
Btu/h
(4.98kW)
0-4500ft
(0-610m)
20,500
Btu/h
(6.01kW)
FPI Fireplace Products International Ltd. Delta BC, CANADA
MADE IN CANADA / FABRIQUÉ AU CANADA
Model: E18E-NG1
1
Model: E18E-LP1
1
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Duplicate Serial number
Part #:
919-998a
Colour:
Black on grey except what is indicated as being printed in red
Size:
H-9.98" x W 3.5" (File at 100%)
Material:
Dec. 13/18: Created draft
Jan. 22/19: Rev A - remodeled decal and added ETL logo at the bottom
This appliance must be installed in accordance with local codes, if any; if none,
follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane
Installation Code, CSA B149.1.
WARNING. This fireplace has been converted for use with a gas fireplace insert
only and cannot be used for burning wood or solid fuels unless all original parts
have been replaced, and the fireplace re-approved by the authority having
jurisdiction.
Cet appareil doit être installé selon les codes et réglements locaux, ou, en leur
absence, se conformer au National Fuel Gas Code, ANSI Z223.1, ou au Natural
Gas and Propane Installation Code, CSA B149.1.
AVERTISSEMENT : Ce foyer a été converti pour utilisation avec un foyer au gaz
encastrable et ne peut être utilisé pour brûler du bois ou d'autres combustibles
solides à moins que toutes les pièces d'origine aient été remplacées et que le
foyer ait été approuvé de nouveau par l'autorité compétente.
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
For use with glass doors certified with the appliance only
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil
Minimum Clearances to Combustibles:
Dégagements minimaux par rapport
aux matériaux combustibles :
Min.
Mantel Height A 17-7/8" (453mm)
Min. Ceiling Height B 37-7/8" (961mm)
D 37-1/2" (953mm)
Side wall E 6" (152mm)
Max. Mantel Depth F 9" (229mm)
Electrical supply / Alimentation électrique 115VAC, 2.5 A, 60Hz,
o
Less than / Moins de 10A Fan Part # 911-071 / Pièce du ventilateur n 911-071
Min. supply pressure
Low Setting Man. pressure
Max. Manifold pressure
Orifice size
Minimum input
Altitude
Maximum input
Factory Equipped For Altitude 0-4500ft. (0-1370m)
F
D
E
B
A
C #: 4001172
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH
SOLID FUELS. /
NE PAS
FOYER AU GAZ À ÉVACUATION -
UTILISER AVEC UN COMBUSTIBLE SOLIDE.
For Use Only with Barrier (Part #616-929 )
Utiliser uniquement avec l’écran (n°616-929)
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Listed/Nom:
VENTED GAS FIREPLACE /
FOYER AU GAZ À ÉVACUATION
Certified to/Certifi :
é
CSA 2.17-2017
ANSI Z21.88-2017 • CSA-2.33-2017
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
919-998a
CSA P.4.1 Fireplace Efficiency (FE) /
Efficacité énergétique des foyers (EEF) CSA P.4.1
Natural Gas / Gaz naturel 69.42%
Propane Gas / Gaz propane 71.42%
CANADIAN ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
ON DEMAND PILOT LIGHT
(SEVEN DAY SAFETY TIMER)
Important information if using the appliance in CPI (continuous pilot mode) only.
This appliance is a ProFlame 1 system fitted with the “On Demand” Pilot, a safety
feature which will shut down the gas valve completely by extinguishing the pilot
light in the event of a continuous full seven days of inactivity.
This only applies if the CPI (continuous pilot) switch is in the “on” position.
Each time the main burner shuts down, manually or through the call from the
thermostat, the seven day timer starts again.
The seven day inactivity timer is controlled within the circuit board. Therefore, if
in CPI mode and when the pilot light is extinguished after seven straight days
of inactivity, the IPI/CPI rocker switch will remain in the “on” position. Therefore,
all that is required to relight the pilot would be to press the on/off button on the
remote control transmitter from “on” to “off” and back to “on”. Once the pilot has
re-established operation will resume as normal. There is no requirement to do
anything with the IPI/CPI rocker switch.
If the unit never goes as long as seven full days without a call for heat, the pilot
will remain lit until it is manually shut-off.
If the unit is being operated in IPI (intermittent pilot) mode, neither the above
instructions nor the seven day timer will apply.
See the instructions in this manual and on the Lighting Instructions plate on the
appliance to light or re-light the pilot.
f i r e - p a r t s . c o m
Summary of Contents for E18E-LP11
Page 95: ...Regency E18E 11 Gas Fireplace Insert 95 notes fire parts com ...
Page 100: ...100 Regency E18E 11 Gas Fireplace Insert warranty fire parts com ...
Page 101: ...Regency E18E 11 Gas Fireplace Insert 101 notes fire parts com ...
Page 102: ...102 Regency E18E 11 Gas Fireplace Insert notes fire parts com ...
Page 103: ...Regency E18E 11 Gas Fireplace Insert 103 fire parts com ...