1. When installing the E18E as a zero clearance, you will use the framing
clearances in the following diagrams. Mantel and inside corner clearances
can be found in Minimum Clearances to Combustibles.
2. Install the Surround to the framing as per manual.
1. Shut down existing unit and allow to cool to room temperature.
2. Turn off gas supply and disconnect electrical.
3. Remove all accessories from existing unit, ie. glass doors, louvers, etc.
4. Remove any tiles, hearth or surround from existing unit (if required).
5. Disconnect gas supply from existing unit.
6. Cut away a perimeter of drywall around the existing unit to expose the fram-
ing. See example below.
7. Uninstall existing unit from framing.
Cut drywall
Remove unit from framing
8. Disconnect venting from existing unit - remove carefully to avoid damage.
9. Remove existing unit from framed opening.
10. Measure framed opening and compare to dimension requirements.
Additional adjustments to framed opening may be required.