ACV40E City Series

installation

Caution Requirements

The top, back and sides of the fireplace are defined by 

standoffs. The metal ends of the standoff may 

NOT

 be 

recessed into combustible construction.

WARNING

Fire hazard is an extreme risk 

if these clearances (air space) to combustible materials are not 

adhered to. It is of greatest importance that this fireplace and vent 

system be installed only in accordance with these instructions.

Clearances

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this 
fireplace and vent system be installed only in accordance with these instructions.

Clearance: single sided

Dimension

Measured From:

A: Mantel Height (min.)

**

Top of Fireplace Opening

B1: From Floor

Min. 0mm

Bottom of Fireplace Opening

B2: Opening Height

383mm

Bottom/Top of Fireplace Opening

C: Sidewall (on one side)

216mm

Side of Fireplace Opening

D: Mantel Depth (max.)

**

E: Alcove Width

2134mm

Sidewall to Sidewall (Minimum)

 F: Alcove Depth

914mm

Front to Unit (Maximum)

G: Ceiling
    (in front of fireplace)

953mm

Top of Fireplace Opening

H: Convection Air Outlet

*

Top of Enclosure

J: Convection Air Outlet Opening Offset

0-76mm

Max. offset from top of chase enclosure

K: Chase Enclosure (Min.)

1600mm

From base of unit/floor

L: Clearance to Sprinkler Head (Min.)

914mm 

Perpendicular from chase grill 

Hearth

0"

No hearth required

** See mantel clearances chart in this manual.

Flue Clearances to Combustibles

Horizontal - Top

76mm

Horizontal - Side 

51mm

Horizontal - Bottom

51mm

Vertical

51mm

Passing  through  wall/
floor/ceiling  -  when 
firestop is used.

38mm

Alcove

E

F

D

A

C

B

1

G

B

2

J

H

K

The 

HeatWave

 Duct Kit has differ-

ent clearance and framing require-
ments, check the 

HeatWave

 manual 

for details.

ACV40E- Single sided

*

A minimum of 306 square 

centimetres of open area, 
not lower than 152mm 
from top of enclosure, 
required for all installations 

L

Chase grill

Sprinkler

Side view

Summary of Contents for City New York View 40 Series

Page 1: ...ervice must be performed by a qualified installer service agency or the gas supplier Warning Fire or explosion Hazard failure to follow safety warnings exactly could result in serious injury death or property damage 920 110 03 03 20 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference LISTINGS...

Page 2: ...r additional information co A BEFORE LIGHTING smell heavier than air and will s WHAT TO DO IF YOU SMELL Do not try to light any a Do not touch any electri Immediately call your ga If you cannot reach your B Do not use this appliance i appliance and to replace a This appliance needs fresh a and ventilation air 1 Ensure the Main switch is in t 2 Press and release the ON OFF using the remote the unit...

Page 3: ...e Height Dimension may vary depending on the height of the leveling legs Note These units are non load bearing ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS ...

Page 4: ...ening B2 Opening Height 383mm Bottom Top of Fireplace Opening C Sidewall on one side 216mm Side of Fireplace Opening D Mantel Depth max E Alcove Width 2134mm Sidewall to Sidewall Minimum F Alcove Depth 914mm Front to Unit Maximum G Ceiling in front of fireplace 953mm Top of Fireplace Opening H Convection Air Outlet Top of Enclosure J Convection Air Outlet Opening Offset 0 76mm Max offset from top ...

Page 5: ...n in the diagram on the right Mantel Leg Clearances Combustible mantel leg clearances as per diagram 254 0 229mm 383mm 254 508 Top of Fireplace Opening 305mm 13mm Plasterboard timber timber panel etc To Bottomof Fireplace Opening 130mm 127 305mm 102mm Allowable mantel MANTEL LEG leg projection 178mm 216mm 51mm ACV40E ...

Page 6: ...ning Height 51mm J Gas Connection Height 106mm K Gas Connection Inset 330mm L Gas Connection Opening Width 89mm Note A combined minimum of 774 square centimetres of open area is required for the convection air outlet to cool the enclosure Ensure clearances for Convection Air Outlets are met See clearances ACV40E single sided in this manual as there are different methods as to how this can be achie...

Page 7: ...30 ACV40E City Series installation TV Recessed into Wall Maximum TV Recess TV Flush with Hearth ACB40E shown ACB40E shown ...

Page 8: ...e 90o two 45o elbows equal one 90o elbow Note Must use optional rigid pipe adapter Part 510 994 when using Rigid Pipe Flueing Systems Maintain clearances to combustibles as listed in Clearances section Horizontal vent must be supported every 0 9 metres Firestops are required at each floor level and whenever passing through a wall A vent guard should be used whenever the termination is lower than t...

Page 9: ...ex Vent 102mm x 173mm These flueing systems in combination with the ACV40E Direct Vent Gas Fireplace have been tested and listed as a direct vent heater system The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in Exterior Vent Termination Locations section Regency Direct Vent Flex System Termination Kits includes all the parts needed to ins...

Page 10: ...ndoff is required it must be used with vinyl siding measure to outside surface of wall without siding and add 51mm When using Rigid Flue other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor WARNING Do not combine flueing components from different flueing systems However use of the the AstroCapTM and FPI Riser is acceptable with all systems Thisproducthasbeenevaluatedb...

Page 11: ...can only be used up to 3m otherwise rigid flueing must be used Horizontal Flueing with Two 2 90o Elbows One 90o elbow Two 45o elbows Option V H H1 With these options maximum total pipe length is 9 1m with minimum of 1 8m feet total vertical and maximum 2 4m total horizontal Please note minimum 0 3mbetween90o elbows is required Min Max A 0 3m 0 6m B 0 6m 1 2m C 0 9m 1 5m D 1 2m 1 8m E 1 5m 2 1m F 1...

Page 12: ...bow Vent must be supported at offsets Minimum distance between elbows is 305mm Maintain clearances to combustibles as listed in the Clearances section Horizontal vent must be supported every 1 2m Firestops are required at each floor level and whenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe vent systems Refer to the Vent Restrictor Position se...

Page 13: ...over 10 12 to 11 12 0 99 over 11 12 to 12 12 1 22 over 12 12 to 14 12 1 52 over 14 12 to 16 12 1 83 over 16 12 to 18 12 2 13 over 18 12 to 20 12 2 29 over 20 12 to 21 12 2 44 Pipe Length Storm Collar Flashing Ceiling Firestop Rigid Pipe Adapter High wind cap This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct Vent Selkirk Direct Temp Ameri...

Page 14: ...evel and whenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe vent systems Vertical Flueing with Three 3 90o Elbows One 90o elbow Two 45o elbows V H1 H V1 Option V H H1 V V1 With these options max totalpipelength is 9 1m with min of 3m total vertical and max 2 4m total horizontal Please note min 0 3m between 90o elbows is required Min Max Min A 0 ...

Reviews: