City Series CV72EPV
|
103
maintenance
Valve Replacement
Important:
Always shut off gas supply/120 volt power prior to servicing the
gas valve.
1. Turn off unit and allow to cool to room temperature.
2. Remove outer enamel or steel panels—see instructions in the panel removal
section in this manual
3. Remove outer safety (barrier) and inner glass (firebox glass)–see instruc-
tions in this manual.
4. Remove all media and logs (if installed) — set aside.
5. Remove inner base panels--see panel section in this manual.
8. Loosen 8 screws in locations shown below (2 at front and 2 at rear)—slide
burner to the left away from the orifice and lift out.
9. Remove 8 screws in locations shown below.
10. Lift valve tray out partially and disconnect flexible gas connection on the
valve inlet side, remove valve tray- replace with new valve tray.
11. Reverse Steps 7-1 to complete.
Burner screw locations
Slide burner to the left and lift out
ttoooollttiipp
ttoooollttiipp
tooltip
tooltip
6. Bend the arm of the aeration lever bracket up from 90° to straighten and
release aeration lever (lever will come with the burner).
tooltip
tooltip
Aeration
lever
Bracket
7. Remove the trim cover on right side of burner by lifting off. Also remove the
burner surround by sliding to the left and lifting off.
Trim cover
Burner Surround