Regency Bellavista
®
B41XTE -11 Gas Fireplace
|
33
installation
Rigid Pipe Venting Systems-Basic Horizontal & Vertical Terminations
Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decora-
tive black, as well as galvanized finish.
The minimum components required for a basic Horizontal Termination are:
1 AstroCap XL Termination Cap
1 90
o
Elbow
1 Rigid Pipe Adaptor
1 Wall Thimble
1 Length of rigid pipe to suit wall thickness
The minimum components required for a basic
Vertical Termination are:
1 Vertical Termination Cap
1 Rigid Pipe Adaptor
1 Lengths of pipe to adequately
penetrate roof
1 Ceiling Firestop
1 Flashing
1 Storm Collar
Wall thickness is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl, furring
strips may be used, instead of a vinyl siding
standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including
furring strips.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
Alternate Snorkel
Termination Cap
HOT
Alternate
Horizontal Termination
Caps
Rigid Pipe
Adaptor (770-994)
Pipe Length
Vertical Terminal
Storm Collar
Flashing
Ceiling Firestop
Pipe
Length
Pipe Length
90 Elbow
o
AstroCap XL
Termination Cap
(Part #946-623/P)
Wall Thimble
(Mandatory in all
Horizontal Terminations)
Vinyl Siding
Standoff (Optional)
Vent Guard - if required*
(Part #946-506/P)
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
This product has been evaluated by Intertek
when using a rigid pipe adaptor and use of
any of the specific chimney systems listed in
this manual. Use of these systems with the
rigid pipe adaptor is deemed acceptable and
does not affect the Intertek WHI listing of these
components.
WARNING:
Do not combine venting components from
different venting systems.
Exception: However, use of the the AstroCap
XL
TM
is acceptable with all systems.
The Regency AstroCap
TM
and Regency Riser Vent terminal are certified for installations using Regency venting systems as well as any specific chimney
systems listed in this manual. AstroCap
TM
is a proprietary trademark of Regency Fireplace Products.