12
| Poêle à bois autoportant Regency CS1205
installation
HAUTEURS DE CHEMINÉE MINIMALES RECOMMANDÉES (EN PIEDS)
(Mesurées à partir du dessus du poêle)
# OF ELBOWS
ÉLÉVATION (pi) AU-
DESSUS DU NIVEAU
DE LA MER
0
2 x 15
o
4 x 15
o
2 x 30
o
4 x 30
o
2 x 45
o
4 x 45
o
0-1000
12.0
13.0
14.0
15.0
18.0
16.0
20.0
1000-2000
12.5
13.5
14.5
15.5
19.0
16.5
21.0
2000-3000
13.0
14.0
15.0
16.0
19.5
17.0
21.5
3000-4000
13.5
14.5
15.5
17.0
20.0
18.0
22.5
4000-5000
14.0
15.0
16.0
17.5
21.0
18.5
23.0
5000-6000
14.5
15.5
17.0
18.0
21.5
19.0
24.0
6000-7000
15.0
16.0
17.5
18.5
22.5
20.0
25.0
7000-8000
15.5
16.5
18.0
19.0
23.0
20.5
25.5
8000-9000
16.0
17.0
18.5
20.0
24.0
21.0
26.5
9000-10000
16.5
17.5
19.0
20.5
24.5
22.0
27.0
NOTE : Pas plus que deux déviations (quatre coudes) permises. Deux coudes 45
o
équivalent à un coude 90
o
.
HAUTEURS DE CHEMINÉE
RECOMMANDÉES
POUR LE POÊLE À BOIS
Règles simples pour un calcul approximatif. Voir
le Tableau 1.
1)
Au niveau de la mer, la hauteur minimale est
de 12 pi (30 cm) en ligne droite.
2)
Ajoutez la hauteur verticale suivante pour
compenser pour chaque :
Coude 45 deg = 1 pi
Coude 90 deg = 2 pi
Té
= 3 pi
Chaque pied de tuyau horizontal = 2 pi.
3)
À cela, ajoutez 4% du total pour chaque 1000
pi au-dessus du niveau de la mer.
Example: a)
1-1/2 pi de tuyau horizontal = 3 pi.
Un Té
= 3 pi.
Somme totale
(au niveau de la mer)
= 6 pi.
Example: b)
Un coude 90 deg.
= 2 pi.
2 pi de tuyau horizontal
= 4 pi.
Un Té
= 3 pi.
Somme totale (au niveau de la mer) = 9 pi.
Hauteur de cheminée recommandée
Élévation Example a) Example b)
0pi 18pi
21pi
1000pi
18.72pi
21.84pi
2000pi
19.44pi
22.68pi
5000pi
21.60pi
25.20pi
8000pi
23.76pi
27.72pi
TABLEAU 1
Draft is the force which moves air from the appliance up through the chimney. The amount of draft
in your chimney depends on the length of the chimney, local geography, nearby obstructions and
other factors. Too much draft may cause excessive temperatures in the appliance and may cause
damage. An uncontrollable burn or excessive temperature indicates excessive draft. Inadequate
draft may cause back puffing into the room and plugging of the chimney. Inadequate draft will
cause the appliance to leak smoke into the room through appliance and chimney connector joints.
Ensure the heater is installed in areas that are not too close to neighbors or in valleys that would
cause unhealthy air quality or nuisance conditions.
Summary of Contents for Alterra CS1205
Page 36: ...36 Po le bois autoportant Regency CS1205 garantie...
Page 37: ...Po le bois autoportant Regency CS1205 37 notes...
Page 38: ...38 Po le bois autoportant Regency CS1205 notes...
Page 39: ...Po le bois autoportant Regency CS1205 39...
Page 76: ......
Page 77: ...Regency CS1205 Freestanding Wood Stove 37 notes...
Page 78: ...38 Regency CS1205 Freestanding Wood Stove notes...
Page 79: ......