Regency CS1205 Freestanding Wood Stove
| 7
installation
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS
MEASUREMENTS "FROM UNIT" ARE FROM THE SIDE SHIELDS OF THE STOVE TO A SIDE WALL OR TO A CORNER, AND FROM
THE REAR HEAT SHIELD TO A BACK WALL
NOTE: Be aware that local Codes and Regulations may override some clearances listed in this manual.
Check with your local inspector.
Residential Installation “C” Vent (Single Wall)
Unit
From Unit
From Corner
From Flue Center-line
CS1205
A
B
C
D
E
F
13"
11"
8"
26-3/8"
18-1/2"
20-3/4"
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from
the stove collar to the ceiling level.
From Unit
From Corner
From Flue Center-line
CS1205
A
B
C
D
E
F
11"
7"
7"
24-1/2"
14.5"
19-3/4"
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)
From Unit
From Corner
From Flue Center-line
CS1205
A
B
C
D
E
F
11"
7"
7"
24-1/2"
14.5"
19-3/4"
A
F
F
C
C
B
E
D
Summary of Contents for Alterra CS1205
Page 36: ...36 Po le bois autoportant Regency CS1205 garantie...
Page 37: ...Po le bois autoportant Regency CS1205 37 notes...
Page 38: ...38 Po le bois autoportant Regency CS1205 notes...
Page 39: ...Po le bois autoportant Regency CS1205 39...
Page 76: ......
Page 77: ...Regency CS1205 Freestanding Wood Stove 37 notes...
Page 78: ...38 Regency CS1205 Freestanding Wood Stove notes...
Page 79: ......