5. Press STEP 2, STEP 3, or OVERRIDE key. Repeat steps 1- 4
to program the corresponding DURATION and SPEED for each
button.
6. Press START to run the VGreen 165 based on the pro-
grammed 24 hour schedule.
7. Pressing the STOP button will stop the VGreen 165.
NOTE:
The VGreen 165 can only be set to operate on a 24-hour sched-
ule. If a user attempts to program a schedule with a combined dura-
tion for all three steps greater than 24 hours, the VGreen 165 software
will retain the current STEP time duration only, and will zero out the
other two STEP time settings. As an example, if STEP 1 equals eight
(8) hours, STEP 2 equals nine (9) hours, and STEP 3 equals eight
(8) hours – for a combined 25 hours – the VGreen 165 will retain the
setting for the current Step being programed and zero out the remain-
ing two. For details regarding the set-up of the three steps as part of a
24-hour schedule, see section 6.