22
6.10 Reset Factory Defaults
The VGreen 165 user interface has a “Reset to Factory Defaults” feature
to restore the schedule settings back to the original values programmed
at the factory. The user must press and hold the STOP and OVERRIDE
buttons for three (3) seconds to reset the settings back to factory
defaults. All of the UI bar graph LED’s will flash three (3) times
to confirm the settings were restored to factory defaults.
7 Priming
The VGreen 165 will always run the PRIMING sequence when starting
from the OFF state, except when starting in OVERRIDE. The factory
Prime settings are 2600 RPM for three (3) minutes.
8 Freeze Protection
In the event that the outside air temperature drops below a set threshold,
the VGreen 165 will automatically turn on (assuming the START button
has been pressed) and circulate the pool water. The Freeze Protection
will run according to the following conditions (utilizing the factory default
settings):
Freeze Protection turn ON temperature = 39°F
Freeze Protection Duration = 1 Hour
By utilizing the VGreen 270 user interface (accessory sold separately)
these factory default settings can be changed.
Once this one (1) hour period has elapsed, the VGreen 165 will check
the ambient temperature again. If the temperature is still below the set
threshold, the VGreen 165 will run for an additional 1 hour. If the tem-
perature is above the threshold, the VGreen 165 will automatically return
to the 24-hour based schedule.
NOTICE
The freeze protection function will NOT operate if the START button is not pressed. This
can be confirmed by verifying that the START LED is illuminated.
10019878-001-001 _V-Green165 UM_7-30-19.indd 24