Viberect-X3

 Penile Vibratory Stimulation 

System 

USER’S GUIDE

 

Made in USA 

 

     

 

                              Indications for Use: 

Viberect

®

 X3 Penile Vibratory Stimulation Device is a hand held medical device 

indicated to provoke ejaculation in men with spinal cord injury. (Prescription use 

in the US).  Over the counter in all other countries. 

PG.1

2216682-A.indd   1

10/24/14   5:52 AM

Summary of Contents for Viberect-X3

Page 1: ...service reflexonic com www Reflexonic com 0459 Viberect X3 Penile Vibratory Stimulation System USER S GUIDE Made in USA Indications for Use Viberect X3 Penile Vibratory Stimulation Device is a hand held medical device indicated to provoke ejaculation in men with spinal cord injury Prescription use in the US Over the counter in all other countries PG 1 2216682 A indd 1 10 24 14 5 52 AM ...

Page 2: ...aculation in SCI men 10 Cleaning Instructions 11 Pad Removal and replacement 11 Electromagnetic emission statements 12 Viberect Product Specifications 13 Symbols Table 13 Customer Service and Contact Information 15 Step by Step Instructions 16 WARNING Spinal Cord Injury use carries risk of Autonomic Dysreflexia PLEASE READ THIS USER MANUAL IN ITS ENTIRETY FOR CORRECT USE AND OPTIMAL RESULTS PG 2 2...

Page 3: ...p men benefit from this modality with ease in the comfort of their home This User s Guide provides information and instructions which must be followed to ensure safe performance of the Viberect device This User s Guide also contains warnings and precautions which must be observed at all times CAUTION ALL STATEMENTS IN THIS GUIDE SHOULD BE FOLLOWED AT ALL TIMES Read the instruction carefully before...

Page 4: ...battery The rechargeable battery in the vibrator contains Nickel Metal Hydride NiMH Like other batteries of this type if burned or punctured it could release toxic material which could cause injury Device has no replaceable internal power source Batteries cannot be replaced by the end user If you wish to dispose of the device do not disassemble components Discard in its entirety Check with local s...

Page 5: ...ation should be stopped immediately Consult your physician Autonomic dysreflexia increase in blood pressure sweating headaches may be caused by various factors such as for instance an over distended bowel or urinary bladder Procedures which involve triggering of orgasm or including vibratory stimulation may precipitate an acute episode of autonomic dysreflexia If the user has spinal cord lesion an...

Page 6: ...ECT Penile Vibratory Stimulation Device Operating Instructions Accessories and detachable parts 1 Soft Pads included are detachable and replaceable Soft Pads replacements order 1680024BK provided in pairs 2 Battery Charger Replaceable PG 6 2216682 A indd 6 10 24 14 5 52 AM ...

Page 7: ...GING INDICATOR Single red LED light indicates that the Viberect device requires charging If no red LED light is visible the device has adequate power for application 4 Pad mode button and indicator The device is capable of 3 modes of operation 1 Vibrating only the top surface of the penis Dorsal 2 Vibrating only the bottom surface of the penis Ventral or 3 Both surfaces recommended for maximal sex...

Page 8: ... blood pressure It is recommended that at least two vibration procedures are performed in a clinical setting before using the Viberect at home The following initial setting is recommended Frequency 100 Hz Amplitude 3 mm constant Place yourself comfortably before turning on the Viberect device Try lying on a firm mattress massage table or even the floor Continue vibration until ejaculation occurs o...

Page 9: ...s properly performed at the head of penis by a trained professional in SCI infertility clinic or a trained spouse Apply at highest setting for two minutes followed by rest for two minutes and another two minutes of stimulation Be prepared for collecting the specimen with a sterile cup PG 9 2216682 A indd 9 10 24 14 5 52 AM ...

Page 10: ... the spasticity and help you become more reactive to PVS You can also have your spouse flex the heel cord Achilles tendon while performing PVS to also help trigger spasticity If you are using any medications to reduce spasticity it can directly interfere with your ability to have successful ejaculation as well So whatever time of day your body is the least affected by these medication will always ...

Page 11: ...ohol pads Removal and Replacement of Viberect Soft Pads If the Viberect Soft Pads start showing any signs of wear and or degradation replace them immediately Specifically check the surface of the pad over mold for any signs of wear degradation and replace if needed and check the integrity of the pad pad over mold assembly Simply pull each pad in the direction directly away from the body of the dev...

Page 12: ...Reflexonic Viberect Page 12 of 16 VIBERECT X3 User Guide 2014 Rev 0 PG 12 2216682 A indd 12 10 24 14 5 52 AM ...

Page 13: ...Ni MH rechargeable 4 AA Temperature Avoid Viberect use in temperatures exceeding 35º C or 95ºF Storage Ambient temperature 68 77ºF 20 25º C Symbols Table Symbol Meaning Batch Code Catalogue Number Consult Instructions for Use Type B applied part Device provides protection against electrical shock Do not discard device improperly Symbol Meaning Caution Do Not Use if Package is damaged Manufacturer ...

Page 14: ...Reflexonic Viberect Page 14 of 16 VIBERECT X3 User Guide 2014 Rev 0 Notes PG 14 2216682 A indd 14 10 24 14 5 52 AM ...

Page 15: ...fficient method Tel 001 301 378 8433 9 00 am 3 00 pm M F US Eastern time Toll Free Fax 800 886 1470 Reflexonic LLC Innovative Urological Solutions 915 Toll House Avenue suite 205 Frederick MD 21701 This User Guide is also available in Spanish German French Portuguese Italian Dutch Chinese Polish www reflexonic com PG 15 2216682 A indd 15 10 24 14 5 52 AM ...

Page 16: ...Reflexonic Viberect Page 16 of 16 VIBERECT X3 User Guide 2014 Rev 0 PG 16 2216682 A indd 16 10 24 14 5 52 AM ...