background image

 

 

 

   Reflexonic® Viberect®                        

                                           Page 4 of 16 

VIBERECT X3 User Guide 2014-Rev-0 

 

BATTERY 

 

The battery in your 

Viberect

® 

has not been charged prior to 

delivery.  

 

A completely discharged 

battery will take approximately 

6-8 hours to fully charge. The 

Red charge indicator will 

extinguish once the charge 

cycle has completed. 

 

To ensure that your Viberect

®

 

is always ready for use, it is 

recommended to recharge the 

battery after use.  Do not 

leave the device on charger 

mode for more than 8 hours. 

 

A fully charged battery will 

allow about 30 minutes of 

vibration at medium frequency 

setting.  

  

When completely discharged, 

allow 6-8 hours to recharge. 

Ensure that the vibrator is 

turned off before recharging.  

 

Use only the charger supplied 

with the vibrator.  Charge the 

Viberect while laying it on its 

side so the two arms are not 

brought together by gravity 

which may turn the device on.   

 

DO NOT ATTEMPT

 to use 

the device while charging. 

 

 

 

 

Disposal of the battery

 

 

The rechargeable battery in the 

vibrator contains Nickel Metal 

Hydride (NiMH).  

 

Like other batteries of this type, if 

burned or punctured, it could 

release toxic material which could 

cause injury.  

 

Device has no replaceable internal 

power source. Batteries cannot be 

replaced by the end user.  If you 

wish to dispose of the device, do 

not disassemble components.  

Discard in its entirety. 

  

 

 

Check with local solid waste 

officials for details concerning 

recycling options and proper 

disposal. In the United States, call 

toll free 1-800-8-BATTERY or visit 

the Battery Recycling Corporation 

website at 

http://www.call2recycle.org/ 

 

The life of NiMH batteries is 

strongly influenced by the care that 

they receive. If properly maintained, 

the battery is capable of more than 

500 charge/discharge cycles before 

dropping to 80% of capacity. Do not 

exceed the allowable ambient 

temperatures during charging, 

operating, or storage. 

  

WARNING  

No modification of this equipment is 

allowed. If this equipment is modified, 

appropriate inspection and testing must 

be conducted to ensure continued safe 

use of equipment. 

 

 

 

 

PG.4

2216682-A.indd   4

10/24/14   5:52 AM

Summary of Contents for Viberect-X3

Page 1: ...service reflexonic com www Reflexonic com 0459 Viberect X3 Penile Vibratory Stimulation System USER S GUIDE Made in USA Indications for Use Viberect X3 Penile Vibratory Stimulation Device is a hand held medical device indicated to provoke ejaculation in men with spinal cord injury Prescription use in the US Over the counter in all other countries PG 1 2216682 A indd 1 10 24 14 5 52 AM ...

Page 2: ...aculation in SCI men 10 Cleaning Instructions 11 Pad Removal and replacement 11 Electromagnetic emission statements 12 Viberect Product Specifications 13 Symbols Table 13 Customer Service and Contact Information 15 Step by Step Instructions 16 WARNING Spinal Cord Injury use carries risk of Autonomic Dysreflexia PLEASE READ THIS USER MANUAL IN ITS ENTIRETY FOR CORRECT USE AND OPTIMAL RESULTS PG 2 2...

Page 3: ...p men benefit from this modality with ease in the comfort of their home This User s Guide provides information and instructions which must be followed to ensure safe performance of the Viberect device This User s Guide also contains warnings and precautions which must be observed at all times CAUTION ALL STATEMENTS IN THIS GUIDE SHOULD BE FOLLOWED AT ALL TIMES Read the instruction carefully before...

Page 4: ...battery The rechargeable battery in the vibrator contains Nickel Metal Hydride NiMH Like other batteries of this type if burned or punctured it could release toxic material which could cause injury Device has no replaceable internal power source Batteries cannot be replaced by the end user If you wish to dispose of the device do not disassemble components Discard in its entirety Check with local s...

Page 5: ...ation should be stopped immediately Consult your physician Autonomic dysreflexia increase in blood pressure sweating headaches may be caused by various factors such as for instance an over distended bowel or urinary bladder Procedures which involve triggering of orgasm or including vibratory stimulation may precipitate an acute episode of autonomic dysreflexia If the user has spinal cord lesion an...

Page 6: ...ECT Penile Vibratory Stimulation Device Operating Instructions Accessories and detachable parts 1 Soft Pads included are detachable and replaceable Soft Pads replacements order 1680024BK provided in pairs 2 Battery Charger Replaceable PG 6 2216682 A indd 6 10 24 14 5 52 AM ...

Page 7: ...GING INDICATOR Single red LED light indicates that the Viberect device requires charging If no red LED light is visible the device has adequate power for application 4 Pad mode button and indicator The device is capable of 3 modes of operation 1 Vibrating only the top surface of the penis Dorsal 2 Vibrating only the bottom surface of the penis Ventral or 3 Both surfaces recommended for maximal sex...

Page 8: ... blood pressure It is recommended that at least two vibration procedures are performed in a clinical setting before using the Viberect at home The following initial setting is recommended Frequency 100 Hz Amplitude 3 mm constant Place yourself comfortably before turning on the Viberect device Try lying on a firm mattress massage table or even the floor Continue vibration until ejaculation occurs o...

Page 9: ...s properly performed at the head of penis by a trained professional in SCI infertility clinic or a trained spouse Apply at highest setting for two minutes followed by rest for two minutes and another two minutes of stimulation Be prepared for collecting the specimen with a sterile cup PG 9 2216682 A indd 9 10 24 14 5 52 AM ...

Page 10: ... the spasticity and help you become more reactive to PVS You can also have your spouse flex the heel cord Achilles tendon while performing PVS to also help trigger spasticity If you are using any medications to reduce spasticity it can directly interfere with your ability to have successful ejaculation as well So whatever time of day your body is the least affected by these medication will always ...

Page 11: ...ohol pads Removal and Replacement of Viberect Soft Pads If the Viberect Soft Pads start showing any signs of wear and or degradation replace them immediately Specifically check the surface of the pad over mold for any signs of wear degradation and replace if needed and check the integrity of the pad pad over mold assembly Simply pull each pad in the direction directly away from the body of the dev...

Page 12: ...Reflexonic Viberect Page 12 of 16 VIBERECT X3 User Guide 2014 Rev 0 PG 12 2216682 A indd 12 10 24 14 5 52 AM ...

Page 13: ...Ni MH rechargeable 4 AA Temperature Avoid Viberect use in temperatures exceeding 35º C or 95ºF Storage Ambient temperature 68 77ºF 20 25º C Symbols Table Symbol Meaning Batch Code Catalogue Number Consult Instructions for Use Type B applied part Device provides protection against electrical shock Do not discard device improperly Symbol Meaning Caution Do Not Use if Package is damaged Manufacturer ...

Page 14: ...Reflexonic Viberect Page 14 of 16 VIBERECT X3 User Guide 2014 Rev 0 Notes PG 14 2216682 A indd 14 10 24 14 5 52 AM ...

Page 15: ...fficient method Tel 001 301 378 8433 9 00 am 3 00 pm M F US Eastern time Toll Free Fax 800 886 1470 Reflexonic LLC Innovative Urological Solutions 915 Toll House Avenue suite 205 Frederick MD 21701 This User Guide is also available in Spanish German French Portuguese Italian Dutch Chinese Polish www reflexonic com PG 15 2216682 A indd 15 10 24 14 5 52 AM ...

Page 16: ...Reflexonic Viberect Page 16 of 16 VIBERECT X3 User Guide 2014 Rev 0 PG 16 2216682 A indd 16 10 24 14 5 52 AM ...

Reviews: