 Universal Condensate Pump

Combi

3004146

Quiet mode:

Installer configurable pump performance using 

DIP-switches to optimize each individual  

installation for the best performance and sound 

parameters.

Diagnostic LED:

Patented two color long-life LED to ensure correct  

inital installation and to assist in diagnostics on 

future service calls.

USB connection:

Patented access for wholesalers or installing 

contractors to review pump history.

Digital sensor:

Unique digital water level sensor with no moving  

parts to get stuck or clogged.

Universal application:

Widest application range for exposed mount pumps  

in the market from 6,000 Btu/H to 

120,000 Btu/H (1.75kW to 35kW).

Integrated replaceable 10 A fuse:

Factory installed replaceable 5 × 20 mm HRC 10A 

fuse for alarm relay operation.

Mode silencieux :

Puissance de la pompe configurables à l’installation à 

l’aide de commutateurs DIP permettant d’optimiser 

chaque mise en service, pour un rendement et un 

niveau sonore optimal.

LED de diagnostic :

LED longue durée bicolore brevetée pour une  

installation initiale correcte et une aide au diagnostic 

des pannes.

Connexion USB :

Accès breveté pour les distributeurs et installateurs, 

afin de consulter l’historique de la pompe.

Sonde numérique :

Sonde numérique de niveau d’eau, sans pièces mobiles 

pour éviter tous risques de blocage ou d’obstruction.

Utilisation universelle :

La pompe à montage externe/interne la plus  

polyvalente du marché, de 1,75 kW à 35 kW  

(de 6 000 Btu/H à 120 000 Btu/H).

Relais d‘alarme à fusible intégré :

Fusible HRC 10 A remplaçable installé en usine de  

5 × 20 mm pour fonctionnement d‘alarme relais.

www.condensate-pumps.com / Combi Manual

July/Juillet 2019

BVM02520200217

Summary of Contents for Combi 3004146

Page 1: ...e 5 20 mm HRC 10A fuse for alarm relay operation Mode silencieux Puissance de la pompe configurables l installation l aide de commutateurs DIP permettant d optimiser chaque mise en service pour un ren...

Page 2: ...ust be replaced WARNING The REFCO condensate pump cables should not be cut and should be routed so that they cannot be damaged during and after installation CAUTION All tubing connections are to be se...

Page 3: ...pompe ATTENTION Les c bles de pompe de condensats REFCO ne doivent pas tre coup s et devraient tre d plac s afin qu ils ne puissent tre endommag s pendant et apr s l installation AVERTISSMENT Tous le...

Page 4: ...hes 5 47 inches 3 43 in 2 09 iches 2 09 inches 11 26 inches 1 89 inches 1 2 3 4 5 7 9 8 6 Suction tube Tube d aspiration Part No R f rence 3004034 13 1 6 inches 1 6 inches 15mm 2 09 iches 2 09 inches...

Page 5: ...Installation PH 2 1 1 2 1a 1b Horizontal installation Installation horizontale Vertical installation Installation verticale 5 www condensate pumps com Combi Manual July Juillet 2019 17 16 13 17 13 BVM...

Page 6: ...2a 1 2 Horizontal installation Installation horizontale 2b 1 Vertical installation Installation verticale 6 www condensate pumps com Combi Manual July Juillet 2019 11 12 11 12 17 17 BVM02520200217...

Page 7: ...2kW medium high up to72K Btu h 21 1kW moyen lev jusqu 72K Btu h 21 1kW high up to120K Btu h 35kW pleine puissance jusqu 120K Btu h 35kW ON 1 2 ON 1 2 ON 1 2 ON 1 2 Ratings for air conditioning units R...

Page 8: ...es sont donn s uniquement titre de renseignement AVERTISSEMENT Isoler l alimentation lectrique avant la connexion WARNING Isolate electrical supply before connection 12 11 8 www condensate pumps com C...

Page 9: ...Alarm Relay Phase 2 Ground L2 L2 L1 3 L2 L1 L1 3 When each Indoor Evaporator Unit is powered from the Outdoor Condenser Unit Utility power 12 11 Electrical Connection INPUT POWER 100 240V 50 60Hz 2 5A...

Page 10: ...s and isolate first Install in accordance with local and regional electrical codes If required install a supplementary fuse on the incoming power rated at maximum 200mA 250vac type TAH250V When Outdoo...

Page 11: ...arme relais Phase 2 Ground L2 L2 L1 3 L2 L1 L1 3 Dans le cas o l vaporateur int rieur est aliment par un condenseur ext rieur Utilisation pour courant 12 11 Electrical Connection INPUT POWER 100 240V...

Page 12: ...conform ment aux codes lectriques locaux et r gionaux Si n cessaire installez un fusible suppl mentaire sur la puissance d entr e nominale 200mA maximum 250V Type Dans le cas o le condenseur ext rieu...

Page 13: ...1 1 6 1 1 2 2 3 3 7 12 11 14 Ins rer prudemment Ne forcez pas Carefully insert Do not force 17 13 www condensate pumps com Combi Manual July Juillet 2019 10 BVM02520200217...

Page 14: ...le to drain vacuer 1 4 I D 6mm Field supplied Partie non fourni Ins rer prudemment Ne forcez pas Carefully insert Do not force 8b 1 2 Vertical installation Installation verticale 14 www condensate pum...

Page 15: ...mpe et verifier que la sequence LED correspondent au mode Alarme relais 12 C est fait Pour red marrer le mode d faut Alarme relais r p ter les tapes de 1 11 1 Unplug pump 2 Move DIP switch positions t...

Page 16: ...de reconfiguration LED Indications in Operation Indications de LED en fonctionnement 16 www condensate pumps com Combi Manual July Juillet 2019 Start Up Sequence S quence de d marrage Pump Status Etat...

Page 17: ...65 6 ft 8 7 1 0 m 3 3 Ft 0 42 42 42 40 40 1 3 3ft 42 42 42 40 39 3 9 9 ft 36 36 35 35 34 5 16 4 ft 30 30 29 29 29 10 32 8 ft 16 16 16 16 15 15 49 2 ft 10 10 10 10 10 20 65 6 ft 7 9 2 0 m 6 6 Ft 0 35 3...

Page 18: ...d stop power to the A C system Only if the alarm wiring is used The drain line could be blocked kinked or pinched You may have incorrect capacity settings on the pump relative to the capacity of the A...

Page 19: ...ue la puissance de la pompe n ait pas t correctement r gl e par rapport la puissance de l installation de climatisation ou au parcours de refoulement vertical important De l eau goutte hors Assurez vo...

Page 20: ...one 413 739 4761 Fax 413 733 9267 sales refcoswiss com www refcoswiss com www refco com 24 7 customer service 1 800 848 4232 4019 3004156 HSG 4065 4 Stop Siphon Device 4 pcs Dispositif Stop Siphon 4 p...

Reviews: