Electrical connections/Operating modes
PARTIAL MUTING
Two types of partial Muting are distinguished and, for both, the “Partial Muting” input pin (pin 6 of the M12
connector of the Active Element) must be used.
1) Partial Muting with Enable
With this option, the Partial Muting function is normally deactivated. To activate this function, the input
signal (pin 6 of the Active Element) must switch from LO to HI (rising edge) before starting the Muting cycle.
The variation of this input signal enables the Partial Muting function only for the first n selected beams
(e.g. with 10 beams as in figure below).
Î
This activation only applies to a STAND-ALONE MUTING CYCLE; It is therefore necessary to reconfirm
Partial Muting activation before any new Muting function request (refer to the timing below).
2) Partial Muting with Disable
With this option the Partial Muting function is normally active (e.g. with 10 beams as in figure below).
To activate this function, the input signal (pin 6 of the Active Element) must switch from LO to HI (rising
edge) before starting the Muting cycle. The changing of that input signal therefore disables the Partial
Muting function.
Î
This activation only applies to a STAND-ALONE MUTING CYCLE; it is therefore necessary to reconfirm
the partial Muting deactivation before any new Muting function request (refer to the timing below).