CONTROL UNIT SERIES AUS X
8540643 - 26/08/2016 Rev.13
3
This symbol indicates an important personal safety warning. Failure to
comply with the warning may result in very high risk for exposed personnel.
INTRODUCTION
The ReeR
control unit is a safety device complying with
IEC 61496-1, IEC 61496-2 specifications. When connected to a Ilion or
a ULISSE/ILION UPC safety photocell, it forms a type 2 ESPE (Electro-
sensitive Protective Equipment).
Possible connections: from 1 to 4 photocells
Restart manual or automatic selectable
2 N.O. outputs with guided contact safety relays
1 system monitor PNP output
1 external contactors feedback input
Connected safety photocells periodic autotest (every 5s) .
Possible connections: from 1 to 4 photocells
Manual or automatic selectable Restart
2 N.O. outputs with guided contact safety relays
1 system monitor PNP output
1 external contactors feedback input
Muting function with two sensors logic
1 Muting function enable input
1 muting lamp output
Muting Override function integrated
Selectable muting timeout
Connected safety photocells periodic autotest (every 5s).
The control unit also guarantees that:
the output lines are open if the photocell is intercepted;
the output lines are enabled only with correct response
times;
in manual mode, maintenance of the RESTART contact
closed is not interpreted as AUTO mode.
For safe use of the device, it is essential to read and understand the contents
of this handbook.
Failure to comply with the prescriptions indicated in this handbook may result
in very high risks for the operating personnel of the machine protected.
Carefully consider the risks analysis of the application and the
legislation of the barrier application Country to establish if the
application is compatible with the safety category 2.