CONTROL UNIT SERIES AUS X
24
8540643 - 26/08/2016 Rev.13
CONNECTION OF AUS XM WITH 4 COUPLES OF ULISSE/ILION PHOTOCELLS IN
SERIES (AUTOMATIC MODE, TIMEOUT MUTING =
)
Figure 16
MUTING FUNCTION
The Muting function is a temporary suspension of the safety light curtain’s
protective function. Carefully check your risk analysis in order to assess
whether the Muting function is compatible with your application and what
additional measures have to be taken.
The Muting function generates a temporary, automatic interruption of
the protective function in order to permit normal transit of material
through the guarded opening.
The Muting function is activated when the system detects the object
that interrupts the opening protected. In other words, when the system
recognizes the material and distinguishes between this and any
operator (in a potentially dangerous situation), it is enabled to bypass
the light curtain temporarily, allowing the material to pass through the
opening.