REED ST-8850 Instruction Manual Download Page 5

reedinstruments

www

com

5

Instrument  
& Function  
Description

1. Windscreen

If you operate the unit in an environment with a wind speed over 10m/sec, 
please put protective accessories (the windscreen provided) in front of the 
microphone.

2. Display

 SYMBOL 

FUNCTION

 

LCD 

4 digits

 

MAX 

Maximum Value hold

  OVER 

Over range

 

Fast response

 

Slow response

 

A-Weighting

 

C-Weighting

 

Lo 

Low Range (35~100dB)

 

Hi 

High Range (65~130dB)

 

BAT 

Low-Battery

continued ...

Summary of Contents for ST-8850

Page 1: ...reedinstruments www com Model ST 8850 Sound Level Meter Instruction Manual...

Page 2: ...this or any other REED product or information on other REED products contact REED Instruments at info reedinstruments com Safety Read the following safety information carefully before attempting to o...

Page 3: ...only specified replacement parts Complies with EMC Features This Sound Level Meter has been designed to meet the measurement requirements of safety engineers health industrial safety offices and soun...

Page 4: ...range 65dB Alarm function OVER is show when input is out of range Maximum hold Hold readings the Maximum Value with decay 1dB 3minutes AC output 0 65 Vrms at FS full scale Output impedance Approx 600...

Page 5: ...wind speed over 10m sec please put protective accessories the windscreen provided in front of the microphone 2 Display SYMBOL FUNCTION LCD 4 digits MAX Maximum Value hold OVER Over range F Fast respon...

Page 6: ...ing the low frequency content of noise If the C Weighted level is much higher than the A Weighted level then there is a large amount of low frequency noise CAL 94dB Calibration using the internal osci...

Page 7: ...OUTPUTS Two outputs can be accessed through a 3 5mm stereo phone plug refer DC output Logarithmic signal 10mV dB Impedance 100 AC output Approx 0 65Vrms corresponding to each range step Impedance 100...

Page 8: ...old Mode function disable 2 Insert the microphone housing carefully into the insertion hole of the calibrator 3 Turn on the switch of calibrator 94dB 1kHz and adjust the CAL potentiometer of the unit...

Page 9: ...back of the meter and install a 9 volt battery in the battery compartment 2 Turn the power on and select the desired response time and weight ing If the sound source consists of short bursts or if it...

Page 10: ..._____ ________________________________________________ ________________________________________________ ________________________________________________ _______________________________________________...

Reviews: