REED ST-8850 Instruction Manual Download Page 4

reedinstruments

www

com

Specifications

Standard applied: 

IEC651 type 2, ANSI S1.4 type 2

Frequency range: 

31.5Hz~8kHz

Measuring level range:  30~130dB
Frequency weighting:  A/C
Microphone: 

1/2 inch electret condenser microphone

Calibration: 

Electrical calibration with the internal 

.

 

oscillator (1kHz sine wave)

Display: 

LCD

Digital display: 

4 digits

Resolution: 

0.1dB

Display Up data: 

0.5 sec.

Time weighting: 

FAST (125ms), SLOW (1 sec.)

Level ranges: 

Lo: 35-100dB, Hi: 65-130dB

Accuracy: 

+ 1.5dB (under reference conditions)

Dynamic range: 

65dB

Alarm function: 

“OVER” is show when input is out of range

Maximum hold: 

Hold readings the Maximum Value, 

.

 

with decay < 1dB/3minutes.

AC output: 

0.65 Vrms at FS (full scale), 

.

 

Output impedance: Approx. 600Ω 

.

 

(FS: means the upper limit of each level range.)

DC output: 

10mV/dB, output impedance approx. 100Ω

Power supply: 

One 9V battery, 006P or IEC 6F22 or NEDA 1604.

Power life: 

About 50 hrs (alkaline Battery)

Operation temperature:  0 to 40°C (32 to 104°F)
Operation humidity: 

10 to 90% RH

Storage temperature: 

-10 to 60°C (14 to 140°F)

Storage humidity: 

10 to 75% RH

Dimensions: 

245 L x 64 W x 31 h mm

Weight: 

255g (including battery)

Includes: 

9V battery, carrying case and instruction manual

Optional Accessory: 

Tripod (REED Model BS-6)

Summary of Contents for ST-8850

Page 1: ...reedinstruments www com Model ST 8850 Sound Level Meter Instruction Manual...

Page 2: ...this or any other REED product or information on other REED products contact REED Instruments at info reedinstruments com Safety Read the following safety information carefully before attempting to o...

Page 3: ...only specified replacement parts Complies with EMC Features This Sound Level Meter has been designed to meet the measurement requirements of safety engineers health industrial safety offices and soun...

Page 4: ...range 65dB Alarm function OVER is show when input is out of range Maximum hold Hold readings the Maximum Value with decay 1dB 3minutes AC output 0 65 Vrms at FS full scale Output impedance Approx 600...

Page 5: ...wind speed over 10m sec please put protective accessories the windscreen provided in front of the microphone 2 Display SYMBOL FUNCTION LCD 4 digits MAX Maximum Value hold OVER Over range F Fast respon...

Page 6: ...ing the low frequency content of noise If the C Weighted level is much higher than the A Weighted level then there is a large amount of low frequency noise CAL 94dB Calibration using the internal osci...

Page 7: ...OUTPUTS Two outputs can be accessed through a 3 5mm stereo phone plug refer DC output Logarithmic signal 10mV dB Impedance 100 AC output Approx 0 65Vrms corresponding to each range step Impedance 100...

Page 8: ...old Mode function disable 2 Insert the microphone housing carefully into the insertion hole of the calibrator 3 Turn on the switch of calibrator 94dB 1kHz and adjust the CAL potentiometer of the unit...

Page 9: ...back of the meter and install a 9 volt battery in the battery compartment 2 Turn the power on and select the desired response time and weight ing If the sound source consists of short bursts or if it...

Page 10: ..._____ ________________________________________________ ________________________________________________ ________________________________________________ _______________________________________________...