Duty Cycle Measurement 

All the measuring procedures are same as a frequency measurement 
except press the Hz/% until the display shows %. 

Zero Adjustment 

Open the input terminal and the capacitor that is not connected and press 
the relative button until the display shows a value of zero. Connect the 
measuring capacitor again and take your measurement. 

Data Hold Operation 

Press the hold button and the displayed value will hold and 

will 

appear. Press the hold button again to release the data hold function. 

Relative Operation 

While taking a measurement the meter will store the last measured value. 
Press the relative button once and LCD will show a value of zero 

.

The newly inputted measured values will automatically be deducted from 
the last measured values and those new values will appear on the display.

 

To release the relative measurement function press the relative button, 
and the 

 marker will disappear. 

Backight Operation 

Push the backlight button for about two seconds for the LCD to illuminate. 

Summary of Contents for CM-9930

Page 1: ...reedinstruments www com Model CM 9930 True RMS AC DC Clamp Meter Instruction Manual...

Page 2: ...t 8 Continuity Check 8 Diode Test 8 9 AC Current Measurement Clamp on 9 DC Current Measurement Clamp on 9 AC Current Measurement Direct input 10 DC Current Measurement Direct input 10 Capacitance Meas...

Page 3: ...ways switch the function rotary switch to the OFF position when the instrument is not operation Remove the battery if the instrument will not be used for an extended period of time Even though the ohm...

Page 4: ...ers Specifications Display 15mm 0 6 4 digit LCD max indication 4000 Measurement Range AC DC ohms diode Hz capacitance duty cycle and continuity beeper Polarity Automatic Switching indicates negative p...

Page 5: ...Clamp on 400A 0 1A 2 5d AC DC 2000A 1000V 2000A 1A 2 8d Ohms 400 ohm 0 1 ohm 1 5d AC DC 400V 4K ohm 1 ohm 40K ohm 10 ohm 400K ohm 100 ohm 4M ohm 1K ohm 2 2d 40M ohm 10K ohm 3 5 5d Capacitance 50nF 10p...

Page 6: ...less than the 30MHz only The accuracy of the capacitance ranges are after the zero adjustment see page 11 has been executed Instrument Description 1 Clamp jaws 10 Manual range select button 2 Trigger...

Page 7: ...ars when the automatic range mode is active Appears when the continuity beeper is active mV V Units for voltage measurements K M Units for resistance measurements Appears when the diode function is ac...

Page 8: ...l now automatically select the suitable measurement range While in auto range mode press the range button to hold the range Continuity Check Connect the Black test lead into the COM terminal Connect t...

Page 9: ...r to open the current sensor jaws and clamp it around the measuring conductor only DC Current Measurement Clamp on Move the function rotary switch to the 2000A position and press the function button u...

Page 10: ...value more than 400mA otherwise the protection fuse will break When taking a direct input measurement and the meter shows a value of 0 check if the protection fuse is broken Capacitance Measurement No...

Page 11: ...tton and the displayed value will hold and will appear Press the hold button again to release the data hold function Relative Operation While taking a measurement the meter will store the last measure...

Page 12: ...replace the housing case Battery Replacement Caution Remove test leads before opening the battery cover 1 When the LCD display shows you will need to replace the battery 2 Loosen the screw on the batt...

Page 13: ..._______________ ________________________________________________ ________________________________________________ ________________________________________________ _____________________________________...

Page 14: ..._______________ ________________________________________________ ________________________________________________ ________________________________________________ _____________________________________...

Page 15: ..._______________ ________________________________________________ ________________________________________________ ________________________________________________ _____________________________________...

Page 16: ...____________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________...

Reviews: