background image

 
 

 

 

 

 

Figure 16 

 
 

 

Figure 17 

 
 
 

 

4. VTA (Vertical Tracking Angle) 
adjustment 
 

a)

 

VTA adjustment screw [6d] must be 
screwed in and rest in the groove 
[2b] in the tonearm base [2]    
(

Figure 16

)   

b)

 

Rotate armtube on the record and let 
down cartridge. 

c)

 

Loosen the tonearm base fixing 
screw [2c] with hex (allen) key [3b] 
(

Figure 16

). 

 
 
 
 
 
 
 
 

d)

 

Adjust armtube height by making it 
parallel to the record. To regulate 
height, screw in or out VTA 
adjustment screw [6d] with hex 
(allen) key [3b] (

Figure 17

). 

 

e)

 

When VTA is adjusted fix tonearm 
base [2] with a fixing screw [2c] 
(

Figure 16

). 

f)

 

Make sure to check VTF setting using 
scales. 

g)

 

Lift up the microlift. 

 
 
 
 
 
 
 

 

Figure 18 

 

 

5. Antiskating adjustment (

Figure 18

 

a)

 

Adjust antiskating force (using test 
record) by turning the handle [6e]. 
Antiskating force is increased by turning 
handle clockwise and decreases by 
turning handle counterclockwise. 

b)

 

Antiskating can be adjusted while playing 
LP. 

 
 
 
 
 
 
 
 
 

Summary of Contents for 1H

Page 1: ...Reed 1H tonearm User manual...

Page 2: ...nstructions may permanently damage the tonearm Figure 2 b Take out the tonearm base 2 Figure 2 Figure 3 c Remove the top packaging layer Put tonearm base 2 into a hole of package top layer d Take out...

Page 3: ...must be embed in sapphire V cup Figure 5 Figure 6 h Screw out the top bearing 4a Figure 3 6 from bearing protection 4c Take the hex allen key 3a Figure 6 from accessories 3 Figure 3 i Srew in a top be...

Page 4: ...d fasten it with the screw 6a Figure 7 k Set tonearm body 6 on the base 2 Fixing screw 6b must match with the groove 2a in tonearm base Fix the screw 6b with hex allen key from accessories Figure 8 l...

Page 5: ...check the position with the template Figure 11 e Drill three 4 2 mm holes and thread them with M5 thread f Fix the armboard in a designated place using a template Figure 11 g Use protractor 1 Figure 1...

Page 6: ...earings of vertical and horizontal axis 4a 4b and 7a 7b are in correct position Figure 14 Failing to set bearings and pivots correctly may permanently damage the cartridge tonearm and LP Figure 15 3 V...

Page 7: ...parallel to the record To regulate height screw in or out VTA adjustment screw 6d with hex allen key 3b Figure 17 e When VTA is adjusted fix tonearm base 2 with a fixing screw 2c Figure 16 f Make sure...

Page 8: ...Figure 19 a If you need to adjust azimuth hold the armtube cylinder 7d and loosen screw 7c by using s 1 5mm Allen key 3c b By carefully turning the armtube 7 clockwise or counterclockwise adjust azimu...