Figure 16
Figure 17
4. VTA (Vertical Tracking Angle)
adjustment
a)
VTA adjustment screw [6d] must be
screwed in and rest in the groove
[2b] in the tonearm base [2]
(
Figure 16
)
b)
Rotate armtube on the record and let
down cartridge.
c)
Loosen the tonearm base fixing
screw [2c] with hex (allen) key [3b]
(
Figure 16
).
d)
Adjust armtube height by making it
parallel to the record. To regulate
height, screw in or out VTA
adjustment screw [6d] with hex
(allen) key [3b] (
Figure 17
).
e)
When VTA is adjusted fix tonearm
base [2] with a fixing screw [2c]
(
Figure 16
).
f)
Make sure to check VTF setting using
scales.
g)
Lift up the microlift.
Figure 18
5. Antiskating adjustment (
Figure 18
)
a)
Adjust antiskating force (using test
record) by turning the handle [6e].
Antiskating force is increased by turning
handle clockwise and decreases by
turning handle counterclockwise.
b)
Antiskating can be adjusted while playing
LP.