background image

20

Accessories and Replacement Parts

• 

R5400

 Line Splitter

• 

R2990

 Thermocouple Adapter

• 

R2920

 Surface Thermocouple Probe

• 

R2930

 Right Angle Thermocouple Surface Probe

• 

R2940

 Air/Gas Thermocouple Probe

• 

R2950

 Immersion Thermocouple Probe

• 

R2960

 Needle Tip Thermocouple Probe

• 

R1020

 Fused Test Lead Set

• 

R1000

 Safety Test Lead Set

• 

CA-05A 

Medium Soft Carrying Case

Don't see your part listed here? For a complete list of all accessories and
replacement parts visit your product page on www.reedinstruments.com.

Appendix A

Flexible AC Current Probe Measurement (R5065 sold separately)

AC Current Measurement with Flexible Probe

1.  Insert the flexible current probe into the negative COM terminal and 

the red test lead into the positive V terminal.

2.  Connect the probe's flexible tubing around the conductor under test. 

If you are opening the end of the flexible probe  
to make the connection, be sure to close and lock it back into place.

3.  Keep the probe coupling more than 1" (2.5cm) away from  

the conductor.

continued...

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Summary of Contents for R5055

Page 1: ...1000A True RMS Digital Clamp Meter Instruction Manual R5055 www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30...

Page 2: ...Frequency Measurement 12 Inrush Current Measurement 12 13 AC DC Voltage Measurements 13 Voltage Frequency Measurement 13 Low Pass Filter LPF ACV Measurement 14 Low Impedance LoZ ACV Measurement 14 LoZ...

Page 3: ...e 20 21 AC Current Frequency Measurement with Flexible Probe 21 Inrush AC Current Measurement 22 Product Care 23 Product Warranty 23 Product Disposal and Recycling 23 Product Support 24 Introduction T...

Page 4: ...y function Do not apply voltage to the meter when resistance function is selected Set the rotary function switch to OFF when the meter is not in use Set the rotary function switch to the appropriate p...

Page 5: ...lated hazardous live conductors is permitted Complies with European Union Standards Conforms to UL STD 61010 1 61010 2 032 61010 2 033 Certified to CSA STD C22 2 No 61010 1 61010 2 032 61010 2 033 CAT...

Page 6: ...tective gloves Built in LED flashlight Low battery and over range indicators Built in non contact voltage detector with LED indicator True RMS voltage and current for accurate measurements Low Pass Fi...

Page 7: ...ce Range 600 6 60 600k 6 60M Accuracy 1 rdg 2 dgt 0 1 0 001k 0 01k 0 1k 0 001M 0 01M Capacitance Range 60 600 0nF 6 60 600uF 6 60mF Accuracy 4 0 rdg 5 dgt Resolution 0 01nF 0 1nF 0 001 F 0 01 F 0 1 F...

Page 8: ...e LoZ Yes Low Pass Filter LPF Yes True RMS Yes Display 6 000 count LCD display Display Hold Yes Max Min Yes Peak Hold N A Zero Push Button Adjustment Yes Relative Mode Yes Diode Test Yes Backlit Displ...

Page 9: ...ator Yes Jaw Opening 1 7 42mm up to 1500 MCM Overvoltage Category CAT III 1000V CAT IV 600V Product Certifications CE ETL Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 14 to 140 F 10...

Page 10: ...lamp 2 Clamp Trigger 3 LCD Display 4 Function Buttons 5 Non Contact Voltage Sensor 6 Non Contact AC Voltage Indicator Light 7 Flashlight Button 8 Rotary Function Switch 9 Flashlight LED Light 10 Batte...

Page 11: ...ired 9 Data Hold Indicator 10 Zero Mode Indicator 11 Diode Test Mode Indicator 12 Audible Continuity Indicator 13 Non Contact Voltage Indicator 14 Low Impedance Measurement Indicator 15 Units of Measu...

Page 12: ...ctor is inside the jaw 2 Press the trigger to the open jaw and fully enclose one conductor NOTE Only one conductor can be measured at a time 3 The LCD will display the reading Current Frequency Measur...

Page 13: ...the negative COM terminal and the red test lead into the positive V terminal 2 Set the rotary function switch to the position and select either AC or DC by pressing the SELECT button 3 Connect the te...

Page 14: ...y measurement mode Low Impedance LoZ ACV Measurement 1 Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal 2 Set the rotary function switch to...

Page 15: ...rminal and the red test lead into the positive V terminal 2 Set the rotary function to the position 3 Press the SELECT button to switch to continuity measurement mode 4 Connect the test leads in paral...

Page 16: ...the capacitor under test 5 The LCD will display the reading NOTE If the measured capacitor is short circuited or the capacitance exceeds the maximum range the LCD will display OL The analog bar graph...

Page 17: ...changing to another function Non Contact Voltage NCV Detection 1 Set the rotary function to the NCV position NOTE Remove test leads from the meter prior to attempting NCV tests Always verify the NCV...

Page 18: ...isplayed on the LCD resets the meter to zero and maintains the stored measurement reading as a reference point for all subsequent measurements 1 Press the REL button to enter relative mode The indicat...

Page 19: ...g on the display 2 While in this mode an H symbol will appear 3 Press the HOLD button again to exit and resume normal operation Backlight Press and hold the button to turn the LCD Backlight on and off...

Page 20: ...lacement parts visit your product page on www reedinstruments com Appendix A Flexible AC Current Probe Measurement R5065 sold separately AC Current Measurement with Flexible Probe 1 Insert the flexibl...

Page 21: ...lead into the positive V terminal 2 Connect the probe s flexible tubing around the conductor under test If you are opening the end of the flexible probe to make the connection be sure to close and lo...

Page 22: ...e device to be tested is turned off set the rotary function switch to the position 5 The meter will automatically switch to the flexible current probe with the extended current range 6 Press and hold...

Page 23: ...oves to be defective because of improper material or workmanship under normal use and maintenance REED Instruments total liability is limited to repair or replacement of the product REED Instruments s...

Page 24: ...struments com Please visit www REEDInstruments com for the most up to date manuals datasheets product guides and software Product specifications subject to change without notice All rights reserved An...

Page 25: ...TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30...

Page 26: ...www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30...

Reviews: