background image

 

 
 
 

 

   

AMP CENTRAL 

Reactive load 

– I.R. Loader  

 

 

 

 
 

Version 1.0 

August 2021 

 

Summary of Contents for AMP CENTRAL

Page 1: ...AMP CENTRAL Reactive load I R Loader Version 1 0 August 2021...

Page 2: ......

Page 3: ...y you re overheating Amp Central for no benefit A fan inside the unit is placed to protect the load from overheating and it will automatically start as soon it will feel the need to Last but not least...

Page 4: ...one very old and one not so old respectively called Dummy Load in our case a Reactive Load and the Impulse Response technology It s a known fact your tube based amplifier needs to have a cabinet wired...

Page 5: ...in and trying the unit What you need to know to proceed in the safest way is to consider the Amp Central as a normal guitar cabinet AMP CENTRAL HAS AN INTERNAL LOAD RATED UP TO 100W 8 OHM USE THE 8 oh...

Page 6: ...s to reach a proper signal without any clipping Turn it up until 0dB led starts to blink at the higher dynamics of your clean channel and then kick it back just a little HEADPHONE LEVEL this pot contr...

Page 7: ...e impedance of the amplifier with your cabinet LINE OUT the line level signal coming from the reactive load without the I R processing applied LINE OUT LEVEL the volume control of the line out FROM AM...

Page 8: ...What to do with crunch or distorted sounds By nature a distorted sound is WAY more compressed so the audio peaks are already smaller than a much cleaner sound at the same SPL If you follow this proce...

Page 9: ...ich is the maximum ability of the internal DSP s calculations If you do some basic math those 20ms will guarantee you a full frequency spectrum response including the super low frequencies even at 40...

Page 10: ...between the IR LOADER section and the output of the Amp Central so this means you re sending the already processed amp signal with the Impulse Response applied to your fx to be processed To the most...

Page 11: ...like your memory stick or hard drive for example with the name AMPCENTRAL Double click on it and you ll see folders with names from 0 to 3 By clicking on each folder you ll find four more folders eac...

Page 12: ...re the same outputs but in a different format XLR can be very convenient to quickly wire the Amp Central to FOH mixers or soundcards There s no global output volume since the INPUT knob will act as th...

Page 13: ...3 3 This is the Control Change list one for each I R Please remember to select an I R on the desired CC you need to send a value equal or greater than 64 for that desired Control Change Control Chang...

Page 14: ...mes you can contact a qualified tech at info HYPERLINK mailto info shivaaudio com HYPERLINK mailto info shivaaudio com HYPERLINK mailto info shivaaudio com redeven amplification com We will reply to y...

Page 15: ......