GUARANTEE 

Terms and Conditions for UK (outside UK contact your local distributor) 

 

In the unlikely event of a product breakdown during the guarantee period you should 

contact our Service and Repair Helpline who will be able to assist with the repair and 

advise of the best course of action to be taken. 

Please DO NOT remove the product prior to making this call as this may invalidate your 

guarantee. 

Service and Repair Tel: 0844 372 7766 or email: [email protected] 

 

We guarantee this product 

for domestic use only

, for a period of 24 months from the date of purchase. 

 

Within the guarantee period we will resolve, 

free of charge

, any manufacturing defects in the product 

resulting from faulty workmanship or material on condition that:- 

 

a)

 

The product has been correctly installed and commissioned in accordance with our instructions and is 
being used on the supply circuit or voltage printed on the rating plate. 

 

b)

 

The product has been used in accordance with these instructions and has not been tampered with                 

or otherwise subject to misuse, neglect or accident. 

 

c)

 

The product has not been taken apart, modified or repaired except by a person authorised by us.

 

 

d)

 

Evidence of the date of purchase in the form of an invoice or receipt will be required in order to qualify 

under the terms of this guarantee. 

 

e)

 

The guarantee period for products used in 

light

 commercial applications will be limited to 12 months. 

We 

DO NOT

 recommend these products be used in heavy or unsupervised commercial applications. 

 

f)

 

For the service work to be undertaken free of charge, the work must only be undertaken by              

Redring Xpelair Group Limited, or our approved agents. 

 

g)

 

Service under guarantee has no effect on the expiry date.                                                                      

The guarantee on any exchanged parts or product ends when the original guarantee period ends. 

 

EXCLUSIONS 

 

This guarantee 

DOES NOT 

cover damage or defects arising from poor or incorrect installation, improper 

use or lack of maintenance, including the build-up of limescale.                                                                

It is the responsibility of the installer to check that the installation parameters meet the requirements              

of the products, and any relevant regulations. 

 

If we are called out to a fault, which is subsequently identified as being an installation fault, we will make 

a charge. 

It is important that the routine checks are completed before calling us out, as many issues can be simply 

diagnosed and resolved.  

A charge will be made where a call under the terms of the guarantee has been booked and a failure was 
not product related, or an engineer arrives and is not able to gain access. 

 

We make no guarantees as to response time for repairs.  

We will endeavour to achieve the most timely response possible but while we indicate an average 

response time, this should not be taken as a guarantee. 

 

The guarantee applies to a repair or replacement (at our discretion) of the product subject to the 

conditions above, and 

DOES NOT

 cover compensation for the loss of the product or consequential                         

loss of any kind. 

 

This guarantee does not apply to the repair or replacement of pressure relief devices, sprayheads, hoses, 

accessories, isolating switches, electrical cable, fuses and/or circuit breakers. 

 

This guarantee does not affect your statutory rights. 

(

A4 Leaflet No. 556-2094-01a) 

Newcombe House, Newcombe Way, 

 

Orton Southgate, Peterborough, PE2 6SE 

 

Tel: +44 (0) 844 372 7761 /  Fax: +44 (0) 844 372 7762

 

 

Technical Service Tel: +44 (0) 844 372 7766

 

 

Technical Service Email: [email protected] 

Summary of Contents for EXPRESSIONS REVIVE

Page 1: ...IMPORTANT This booklet should be left with the user after installation and demonstration Installation and User Guide EXPRESSIONS REVIVE and EXPRESSIONS REVIVE PLUS SMARTFIT 2 ELECTRIC SHOWERS...

Page 2: ...form to any local regulations in effect This appliance is intended to be permanently connected to the fixed electrical wiring of the mains supply with its own dedicated supply This appliance must NOT...

Page 3: ...ting may give adequate hot water Your shower is designed to stabilise temperature changes caused by water pressure fluctuations These can result from toilets being flushed or taps being turned on and...

Page 4: ...front cover a poor fit 3 Adjust the position to get the most convenient arrangement taking the following into account DO NOT MOUNT THE UNIT IN THE DIRECT HANDSET SPRAY The handset must not be able to...

Page 5: ...BING WARNING ENSURE THAT THE MAINS WATER SUPPLY MEETS THE REQUIREMENTS BELOW BEFORE CONTINUING INSTALLATION The shower unit must be connected to the mains cold water supply This must have a minimum su...

Page 6: ...6 Showing Right Side Entry Left Side Entry is available for all options by exchanging the fitted end cap fig 7 5 2 5a 2 5b 2 5c 2 5d 2...

Page 7: ...7 7 5e 2 5f 2 6 2 Also refer to page 8 for further water inlet entry information...

Page 8: ...the spring clip back into position fig 8b Ensure end cap is securely fitted to previous pipe entry Rear Entry positions If Right Entry swivel the fitted compression elbow to face a rear entry pipe con...

Page 9: ...nces 2 A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules We recommend a ceiling switch mounted in a convenient position 3 Cut back cab...

Page 10: ...full turn mid position should be at approximately 1 o clock 11 If you have not yet done so assemble your Smart Fit Accessories fig 12 12 Set the power select knob to COLD position and check the tempe...

Page 11: ...sure the round opening points downward 3 Put the shower holder hose retainer and soap dish into the sliding rail and ensure the larger opening of the shower holder point upward Be sure that the notch...

Page 12: ...at you do not wholly enter the water spray during this period especially if the shower has just been used If the water is not at your desired showering temperature turn Knob B a small amount until the...

Page 13: ...djusted The COLD setting of Knob A will supply water without any heating During normal operation if an overheated water temperature is sensed then the heating elements will be switched off The Power l...

Page 14: ...ARS WITH OUR APPROVED PART IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER YOU MUST CLEAN THE SHOWER HANDSET REGULARLY YOU MUST REGULARLY INSPECT THE HANDSET FOR WEAR AND DAMAGE AND REPLACE IF NEC...

Page 15: ...d water temperature is achieved by adjusting the rate of water flow The diagram shows the principle involved in relating temperature rise to flow rate The higher the water rate the lower the temperatu...

Page 16: ...ly Fully open service valve stop cock Check hose is not kinked restricting the water flow Clean handset Check and clean filter if necessary Water too COLD Decrease water flow by adjusting Knob B clock...

Page 17: ...liser valve Check stabiliser is in place and remove any debris in valve Water discharge from pressure relief valve Check for cause of high pressure and remove it Blockage on outlet e g blocked shower...

Page 18: ...e slot d Pressure Relief Device m Wall Fixing Slot e On Off Solenoid Valve n Relay Expressions Revive Plus only f Pressure Switch o Timer PCB Expressions Revive Plus only g Terminal Block x 2 p Power...

Page 19: ...tal Clip Set Cat No 93672180 Solenoid Valve Cat No 93672176 6 Mode Handset Cat No 93672159 Start Stop Switch Cat No 93590713 Chrome Shower Hose Cat No 93672119 Flow Valve Top Assembly Cat No 93672105...

Page 20: ...up Limited or our approved agents g Service under guarantee has no effect on the expiry date The guarantee on any exchanged parts or product ends when the original guarantee period ends EXCLUSIONS Thi...