background image

 

2

INTRODUCTION 

If you experience any difficulty with the installation or operation of your new 

shower, then please refer to the “What to do if things go wrong” section in this 

manual before contacting us. 

 
 

 

 

Thank you for purchasing a quality 

Redring Active 320S Electric Shower

 manufactured in England. 

To enjoy your new shower at its best, please take time to read this manual thoroughly  to 

familiarise yourself with all instructions, BEFORE beginning installation. 

 

The 

Redring Active 320S

 is an electric shower incorporating our 

“Smart Technology”

 and a unique 

dual control combining on/off, power select and flow/temperature control.  
Your shower is designed to stabilise temperature changes caused by water pressure fluctuations.                                          
These can result from toilets being flushed or taps being turned on and off.  
When this happens your showering temperature will be held within a controlled band, provided that 
the minimum pressure required by the shower is maintained (see “Effect of Other Water Devices”). 

 

 

 

 

 

1.

 

Your shower has been designed for convenience, economy and safety of use, provided that it is 
installed, used and maintained in good working order and in accordance with our instructions and 

recommendations. 

2.

 

All wiring and installation must be supervised by a suitably qualified person. 

3.

 

THIS APPLIANCE MUST BE EARTHED. 

4.

 

The installation must be in accordance with the current edition of BS.7671 (

the “IEE Wiring

 

Regulations”)

 and “Part P” of the 

“Building Regulations”

 in force at the time of installation. 

Installations outside England and Wales must also conform to any local regulations in effect. 

This appliance is intended to be permanently connected to the fixed electrical wiring of the mains 
supply with its own dedicated supply. 

5.

 

This appliance must 

NOT

 be fitted where it may be subjected to freezing conditions 

6.

 

DO NOT

 switch the appliance on if you suspect it of being frozen.                                                             

Wait until you are sure it has thawed out. 

7.

 

DO NOT

 fit any sort of tap or control on the appliance outlet.  The appliance is designed to have 

an open outlet and should only be used with “Redring” recommended fittings.     

8.

 

The shower handset provided is designed to work with electric showers.                                                  
Only use the manufacturers approved accessories with this shower.

 

 

9.

 

Take care to avoid restricting the outlet of the pressure relief device.  If water is discharged from 
the pressure relief device, maintenance will be required before the appliance can be safely used.

 

10.

 

Isolate the mains electrical and water supply before removing the front cover of the appliance. 

Section 
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
How to install your 

Active 320S

 Shower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

How to maintain your 

Active 320S

 Shower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

How to use your 

Active 320S

 Shower (Detailed) . . . . . . . . . . . . . . . . . . . . . . . . . . . .   

What to do if things go wrong (1) Self Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   
Additional Accessories and Common Spare Parts . . . . . . . . . . . . . . . . . . . . . . . .  . . .   

What to do if things go wrong (2) Professional Service . . . . . . . . . . . . . . . . . . . . . . .  
Redring After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
How your 

Active 320S

 Shower Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

Guarantee and Contact Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
How to use your 

Active 320S

 Shower (Summary) . . . . . . . . . . . . . . . . . . . . . . . . . . .   

Page 








10 

11 
12 

CONTENTS 

IMPORTANT SAFETY INFORMATION 

 

11

 

 

 
 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 
 
 
 
 

 
 
 

 
 
 
 
 
 
 

 

Full details of terms and conditions are available on request from:-

 

 

APPLIED ENERGY PRODUCTS LIMITED 

MORLEY WAY, PETERBOROUGH PE2 9JJ 

TEL:  +44 (0) 844 372 7761  

 FAX: +44 (0) 844 372 7762 

Website: www.redring.co.uk 

 

GUARANTEE AND CONTACT DETAILS 

Summary of Contents for Active 3205

Page 1: ...d showering turn outer knob A anti clockwise to the position You have no need to adjust inner knob B 5 Water will continue to flow for up to 3 seconds before switching off This reduces the temperature of the water in the tank for the next user The neon indicator light will go out 6 Switch off the electricity supply at the ceiling switch or local isolator Notes Wait 20 seconds for the temperature t...

Page 2: ...o conform to any local regulations in effect This appliance is intended to be permanently connected to the fixed electrical wiring of the mains supply with its own dedicated supply 5 This appliance must NOT be fitted where it may be subjected to freezing conditions 6 DO NOT switch the appliance on if you suspect it of being frozen Wait until you are sure it has thawed out 7 DO NOT fit any sort of ...

Page 3: ...turned on and off When this happens your showering temperature will be held within a controlled band provided that the minimum pressure required by the shower is maintained Your shower requires a minimum running pressure of 69kPa 0 7 bar 10 psi At pressures above 69kPa 0 7 bar 10 psi it will minimise temperature fluctuations as detailed above If the water pressure falls below 69kPa 0 7 bar 10 psi ...

Page 4: ...will prevent the heater working properly Note You may be charged for a service call if it is due to incorrect installation 7 The shower is designed to have an open outlet and should only be used with Redring recommended fittings Do not connect the handset until after the shower front cover and corner section are fitted WARNING DO NOT FIT A TAP ON THE SHOWER OUTLET WARNING TAKE CARE TO AVOID RESTRI...

Page 5: ...1 25 metre Shower Hose Cat No 93797641 Tank Base Assy 7 2kW Cat No 93597858 Chrome Multi Mode Accessories Cat No 83595318 Tank Base Assy 8 5kW Cat No 93597859 Chrome Premium Accessories Cat No 83595319 Solenoid Valve Cat No 93597868 Chrome Curved Accessories Cat No 83595320 Neon Cable Assy Cat No 93593576 Curtain and Rail Pack Cat No 83792812 Tank Clip Cat No 93768309 Curtain and Rail Pack with PR...

Page 6: ...ning clockwise until you get the water temperature of your liking Wait 20 seconds after each adjustment for the water temperature to stablise IF WATER IS TOO HOT Turn inner knob B anti clockwise in the direction of the blue arrows to 11 o clock and continue turning anti clockwise until you get the water temperature of your liking Wait 20 seconds after each adjustment for the water temperature to s...

Reviews: