Redring Active 3205 Installation And User Manual Download Page 3

 

10

 

 

 

 

 
1.

 

Water is heated instantaneously as it flows over the                                                                                
heating elements in the copper cylinder (Diagram 8). 

 

2.

 

The heaters are only switched on when sufficient                                                                                                     
water is flowing.                                                                                                                                                            

This is done automatically with a switch which                                                                               
works on water pressure and is indicated by the                                                                                   
neon light illuminating depending on the power                                                                                               
selected by outer knob “A”. 

 

3.

 

The water is turned on and off by the solenoid                                                                              

valve built into the shower.                                                                                                                                   
This is switched on when outer knob “A” is                                                                                            
clicked clockwise. 

 

4.

 

The flow of water is automatically held at the level set                                                                                               
by the user even though the supply pressure may vary                                                                            
(see “Effect of Other Water Devices on Incoming Water Supply”). 

 

5.

 

If the water supply falls below a set limit, the pressure                                                                       
switch will operate and switch off the power to the elements.                                                                
This is indicated by the neon light going out (see “Effect of Other Water Devices on Incoming 
Water Supply”). 

 

6.

 

As a further safeguard

, a thermal cut-out switches the power off if the water temperature 

climbs above the set limit.  This cut-out, which gives an audible click, may also operate due to 
residual heat when the shower is switched off.                                                                                                  
It will reset itself if water is run through the shower for 10 to 20 seconds. 

 

7.

 

The pressure relief device is to safeguard against abnormal pressure conditions, and provides a 
level of appliance protection should an excessive build of pressure occur within the shower. 

 

Effect of Seasonal Incoming Water Temperature Changes 

 

The required water temperature is achieved by adjusting the rate of water flow.   
Diagram 9 shows the principle involved in relating temperature rise to flow rate.                                 
The higher the water rate the lower the temperature and vice versa.                                               
The temperature of the water supplied from the mains can vary considerably                                      
throughout the year from 5 to 20°C.                                                                                                                    
This means that in the winter, flow rate will be less than in the summer to                                                            

achieve the same outlet temperature.                                                                                                                           
In summer the “  (medium)” power setting may give adequate hot water. 
 

Effect of Other Water Devices on Incoming Water Supply 

 

Your shower is 

designed to stabilise temperature

 changes caused by water pressure 

fluctuations.  These can result from toilets being flushed or taps being turned on and off.                                 
When this happens your showering temperature will be held within a controlled band, provided that 
the minimum pressure required by the shower is maintained. 

 

Your shower requires a minimum running pressure of 69kPa (0.7 bar, 10 psi).                                                                                    
At pressures above 69kPa (0.7 bar, 10 psi) it will minimise temperature fluctua tions as detailed 
above.  If the water pressure falls below 69kPa (0.7 bar, 10 psi) it is likely that the pressure switch 
will turn off the power to the heating elements, resulting in a cold shower.                                                           
This will be indicated by the neon light going out. 

 

HOW YOUR 

ACTIVE 320S

 SHOWER WORKS 

 

3

 

 

 
 
 

WARNING: ALL WIRING AND INSTALLATION MUST BE 

SUPERVISED BY A SUITABLY QUALIFIED PERSON. 

 

WARNING: DO NOT INSTALL THIS SHOWER WHERE IT MAY BE 

SUBJECTED TO FREEZING CONDITIONS 

 

We recommend that the installation is done in the following sequence. 

 

a. Fixing the shower to the wall    b. Plumbing   c. Electrical connections 

 

a.

 

FIXING THE SHOWER TO THE WALL 

 

1.

 

Position the riser rail at a convenient height for majority of users as 
detailed in Diagram 1 and mark its position (also see separate 
accessories fitting instructions). 

 

2.

 

Position the heater so that the top of the unit is horizontal and level 
with, 

or a maximum of 0.6 metres (2ft) below the top of the 

riser rail

.  Choose a flat piece of wall to avoid the possibility of 

distorting the backplate thus making the front cover a poor fit. 

 

3.

 

Adjust the position to get the most convenient arrangement taking 

the following into account. 

 

The heater must not be mounted in the direct spray from the handset. 

 

 

The handset must not be able to come into contact with used water in the cubicle, bath or 

basin.  If it can, even after the hose has been retained by the retaining ring (see separate 
accessories fitting instructions sheet), a vacuum breaker must be fitted. 

 

4.

 

Fix the riser rail with screws provided (see separate instructions supplied with accessories).                           

5.

 

Decide the position of the electrical cable into the unit.                                                                                
If top or bottom entry is chosen (according to Diagram 7 on page 9), cut away the walls in the 
backplate as shown in Diagram 2. 

 

6.

 

Decide the position of entry of the cold water pipe into the unit.                                                                   
If top, cut away the backplate.  If rear, please read the section on plumbing.                                                                                           
If bottom, remove the front cover (complete with knobs) and cut away the detachable corner 
section as shown.  

HOW TO INSTALL YOUR 

ACTIVE 320S

 SHOWER 

Summary of Contents for Active 3205

Page 1: ...d showering turn outer knob A anti clockwise to the position You have no need to adjust inner knob B 5 Water will continue to flow for up to 3 seconds before switching off This reduces the temperature of the water in the tank for the next user The neon indicator light will go out 6 Switch off the electricity supply at the ceiling switch or local isolator Notes Wait 20 seconds for the temperature t...

Page 2: ...o conform to any local regulations in effect This appliance is intended to be permanently connected to the fixed electrical wiring of the mains supply with its own dedicated supply 5 This appliance must NOT be fitted where it may be subjected to freezing conditions 6 DO NOT switch the appliance on if you suspect it of being frozen Wait until you are sure it has thawed out 7 DO NOT fit any sort of ...

Page 3: ...turned on and off When this happens your showering temperature will be held within a controlled band provided that the minimum pressure required by the shower is maintained Your shower requires a minimum running pressure of 69kPa 0 7 bar 10 psi At pressures above 69kPa 0 7 bar 10 psi it will minimise temperature fluctuations as detailed above If the water pressure falls below 69kPa 0 7 bar 10 psi ...

Page 4: ...will prevent the heater working properly Note You may be charged for a service call if it is due to incorrect installation 7 The shower is designed to have an open outlet and should only be used with Redring recommended fittings Do not connect the handset until after the shower front cover and corner section are fitted WARNING DO NOT FIT A TAP ON THE SHOWER OUTLET WARNING TAKE CARE TO AVOID RESTRI...

Page 5: ...1 25 metre Shower Hose Cat No 93797641 Tank Base Assy 7 2kW Cat No 93597858 Chrome Multi Mode Accessories Cat No 83595318 Tank Base Assy 8 5kW Cat No 93597859 Chrome Premium Accessories Cat No 83595319 Solenoid Valve Cat No 93597868 Chrome Curved Accessories Cat No 83595320 Neon Cable Assy Cat No 93593576 Curtain and Rail Pack Cat No 83792812 Tank Clip Cat No 93768309 Curtain and Rail Pack with PR...

Page 6: ...ning clockwise until you get the water temperature of your liking Wait 20 seconds after each adjustment for the water temperature to stablise IF WATER IS TOO HOT Turn inner knob B anti clockwise in the direction of the blue arrows to 11 o clock and continue turning anti clockwise until you get the water temperature of your liking Wait 20 seconds after each adjustment for the water temperature to s...

Reviews: