background image

Термопот

RTP-805

Руководство по эксплуатации

Если вы не получили требуемое качество обслуживания 

в сервисе, обращайтесь в головной сервисный  центр 

по  контактным  данным,  указанным  в  условиях 

гарантийного обслуживания

Summary of Contents for RTP-805

Page 1: ...RTP 805...

Page 2: ...ance mode 10 Manual water supply 11 Automatic water supply 11 Changing the program setting 11 Water cooling mode 11 Timer setting 12 Autonomous water supply function 12 III CLEANING AND MAINTENANCE 12...

Page 3: ...3 A1 1 6 2 4 5 10 11 3 8 9 7...

Page 4: ...4 A2 1 15 4 5 13 14 2 3 6 12 7 8 10 11 9...

Page 5: ...5 A3 a a b 1 2 1 2 3 a b c a b A4...

Page 6: ...uld this happen manufac turerisnotresponsibleforpossibleconsequences Before plugging in the appliance ensure that the circuit voltage matches operating voltage of the appliance see technical specifica...

Page 7: ...lt in damage Use the appliance at an altitude of no more than 2000 m Before cleaning the appliance ensure that it is unplugged and has cooled down Follow the in structions while cleaning the device DO...

Page 8: ...on available Battery 4 LR06 Capacity 5 l Operation modes water boil heating water without boiling heating 45 90 C in 5 C increments cooling Type of control touch Autonomous water supply function avail...

Page 9: ...th indicator water cooling mode 5 button set water temperature maintaining mode 6 button heating temperature decrease 7 Display 8 Set temperature digital indicator 9 Current temperature digital indica...

Page 10: ...tton to select heating with pre boil indi cator recommended when using unfiltered water or heat ing without pre boiling indicator recommended when using filtered water 4 Use the and buttons to set the...

Page 11: ...ngs To do this 1 Press the button to unlock water supply the button indi cator will light up 2 Pressthe or button thewatersupplyprocesswillstart 3 Release the button when the desired volume is reached...

Page 12: ...splaywill show the set water temperature and the timer value the indicators of the and buttons will be constantly lit 5 When the timer is reset the indicator of the button will turn off the thermopot...

Page 13: ...nd scale may form on the heating element and the in ternal walls of the appliance Use special non abrasive agents for cleaning and descaling kitchen appliances to remove them Follow the cleaning agent...

Page 14: ...sions in the water tank Descale the tank see Cleaning and Maintenance A loud sound is heard during boiling Scale has formed on the walls of the water tank In case you didn t manage to eliminate the de...

Page 15: ...40 21 337 1099 www asbis ro RU 198099 38 2 7 812 740 16 30 SK Import r distrib tor pre SR ASBIS SK spol s r o Tuhovsk 33 831 06 Bratislava Tel 440 2 32165111 www online asbis sk RS Uvoznik i servis z...

Page 16: ...www redmond company www multivarka pro www store redmond company www smartredmond com Made in China RTP 805 ENG UM 1...

Reviews: