MODELS WITH RS485 OR LINEAR DC ANALOG OUTPUT

ORDERING INFORMATION

Options and Output Boards are factory configured per the part number specified. Part numbers without 

replacement output boards listed must be returned to the factory for output board replacement. 

MODELS WITHOUT RS485 AND LINEAR DC ANALOG OUTPUT

NA

RBD48211

RBD48211

RBD48211

RBD48211

RBD48200

RBD48111

RBD48111

RBD48111

RBD48111

RBD48100

REPLACEMENT 

OUTPUT 

BOARD

Logic/SSR

T4832200

T4832210

Logic/SSR

Triac

Relay

T4821104

T4821114

YES

Relay

Logic/SSR

Relay

T4821103

T4821113

YES

Relay

Logic/SSR

Relay

T4821100

T4821110

Relay

Logic/SSR

Relay

T4821000

NA

Logic/SSR

T4820000

T4820010

Logic/SSR

Relay

T4811104

T4811114

YES

Relay

Relay

Relay

T4811103

T4811113

YES

Relay

Relay

Relay

T4811100

T4811110

Relay

Relay

Relay

T4811000

NA

Relay

T4810000

T4810010

Relay

PART NUMBERS

85 TO 250 VAC

18-36 VDC/24 VAC

DEDICATED  

ALARM 1 

A1 OUTPUT

*

 - This output is programmable as either Control (PID) or as an Alarm.

@ - These part numbers are equipped with a second setpoint.

T4821102

T4821112

T4820209

T4820219

T4820208

T4820218

T4820206

T4820216

T4820205

T4820215

T4820201

T4820211

T4811102

T4811112

T4810109

T4810119

T4810108

T4810118

T4810107

T4810117

T4810106

T4810116

T481010A

T481011A

T4810105

T4810115

T4810101

T4810111

T4810002

NA

PART NUMBERS

85 TO 250 VAC

18-36 VDC/24 VAC

Relay

YES

Relay

Logic/SSR

Logic/SSR

YES

YES

Logic/SSR

Logic/SSR

YES

YES

Logic/SSR

Logic/SSR

YES

Logic/SSR

YES

Logic/SSR

YES

Logic/SSR

YES

Logic/SSR

YES

Logic/SSR

Relay

YES 

2

Relay

Relay

Relay

YES

YES

Relay

Relay

YES

YES

Relay

Relay

YES

Relay

YES

Relay

YES

Relay

YES

Relay

YES

YES

Relay

Relay

YES

Relay

YES

Relay

YES

Relay

YES 

1

Relay

SECOND 

ANALOG 

  OUTPUT** @

HEATER 

CURRENT 

INPUT @

DEDICATED  

MAIN CONTROL 

O1 OUTPUT

DEDICATED 

ALARM 1 

A1 OUTPUT

RS485 

@

*

 - This output is programmable as either Control (PID) or as an Alarm.

** 

-

 

This output is jumper and program selectable for either a current or voltage Linear DC output.

@ - These part numbers are equipped with a second setpoint.

- Replacement Output Board RBD48100 may be used.

- Replacement Output Board RBD48111 may be used.

 DESCRIPTION

PART NUMBERS

RLY

Three Phase DIN Rail Mount SSR

Single Phase 40 A DIN Rail Mount SSR

Single Phase 25 A DIN Rail Mount SSR

External SSR Power Unit  (for Logic/SSR output models) 

RLY70000

RLY6A000

RLY60000

RLY50000

CT

40 Ampere Current Transformer (for Heater Current Input models)

CT004001

50 Ampere Current Transformer (for Heater Current Input models)

CT005001

ICM5

ICM4

SFCRM

ICM40030

SFCRM

Three way isolated RS232/RS485 Serial Converter 

RS232/RS485 Serial Converter Module

ACCESSORIES

REMOTE 

SETPOINT 

INPUT @

DEDICATED  

MAIN CONTROL 

01 OUTPUT

REMOTE 

SETPOINT 

INPUT @

HEATER 

CURRENT 

INPUT @

(ALARM 2) 

A2 OR 02 

(COOL)*

(ALARM 2) 

A2 OR O2 

(COOL) 

*

MAIN CONTROL 

O1 OR A1 

(ALARM 1) 

*

MAIN 

ANALOG 

OUTPUT** @

Option Boards are installed at the factory for the appropriate models. These boards are only needed for field replacement.

Crimson 2 PC Configuration Software for Windows 98, ME, 2000 and XP (for RS485 models)

ICM50000

* Crimson software is available for download from http://www.redlion.net

MODEL NO.

Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839

Red Lion Controls

China

Unit 302, XinAn Plaza

Building 13, No.99 Tianzhou Road

ShangHai, P.R. China 200223

Tel +86 21 6113 3688

Fax +86 21 6113 3683

Red Lion Controls

Europe

Softwareweg 9

NL - 3821 BN Amersfoort

Tel +31 (0) 334 723 225

Fax +31 (0) 334 893 793

Red Lion Controls

India

201-B, 2nd Floor, Park Centra
Opp 32 Mile Stone, Sector-30

Gurgaon-122002 Haryana, India

Tel +91 984 487 0503

Summary of Contents for T48

Page 1: ...esponse without excessive overshoot The unit can be transferred to operate in the manual mode providing the operator with direct control of the output The controller may also be programmed to operate in the ON OFF control mode with adjustable hysteresis A second setpoint is available on select models to allow quick selection of a different setpoint setting Dual 4 digit displays allow viewing of th...

Page 2: ...ROLS Four front panel push buttons for modification and setup of controller functions and one external input user for parameter lockout or other functions 4 MEMORY Nonvolatile E2 PROM retains all programmable parameters and values 5 MAIN SENSOR INPUT Sample Period 100 msec Response Time Less than 300 msec typ 400 msec max to within 99 of final value w step input typically response is limited to re...

Page 3: ...e 300 to 9600 Data Format 7O1 7E1 7N2 8N1 Node Address 0 99 max of 32 units per line Transmit Delay 2 100 msec or 100 200 msec Data Encoding ASCII Isolation w r t Main Input Common 500 Vrms for 1 min 50 V working Not isolated w r t Remote Setpoint or Heater Current inputs or Analog Output common Note RS485 and the Analog Output commons are not internally isolated within the controller The terminat...

Page 4: ...on The output can be set for 0 to 10 V 0 to 20 mA or 4 to 20 mA ranges and can be configured for control or for transmission of temperature or setpoint values A Second Linear DC output is dedicated for retransmission of input temperature The output can be scaled and converted independent of the input and Main Linear DC output This output is isolated from the input SETPOINT FEATURES The controller ...

Page 5: ...t higher limit SPrP Enter setpoint ramp rate InPt Select user input function Configuration 2 Outputs 2 OP CYCt Enter time proportioning cycle time OPAC Select output control action OPLO Enter output power low limit OPHI Enter output power high limit OPFL Enter probe fail power preset OPdP Enter output control dampening CHYS Enter ON OFF control hysteresis tcOd Select auto tuning dampening ANtP Mai...

Page 6: ... the Heater Current Monitor Part Number CT005001 Current Ratio 50 0 1 Amperes Operation Frequency 50 to 400 Hz Insulation Class 0 6 KV BIL 10 KV full wave Terminals Brass studs No 8 32 UNC with flat washer and hex nuts Window Diameter 1 13 28 7 mm Weight 8 oz 226 0 g 1 2 3 4 5 6 7 8 9 10 13 14 12 11 2 39 60 7 MAX 1 96 49 8 MAX PANEL LATCH INSTALLED FOR VERTICAL UNIT STACKING HORIZONTAL UNIT STACKI...

Page 7: ... than 12 outside the manufacturer s specifications of 140 to 150 F 11 12 14 13 10 9 8 7 6 5 4 3 2 1 USER INPUT COMM TC RTD AL2 O2 COMM AL1 O1 N O COMM AC POWER 85 250 VAC AC POWER POWER AC NO GO GO 13 14 12 11 10 9 8 7 6 5 4 3 2 1 OUT OUT 02 A2 COMM 01 A1 USER INPUT COMM TC RTD IN IN SLAVE CONTROLLER 1 TC COMM 4 9 01 A1 5 MASTER CONTROLLER 11 12 10 RTD IN 02 A2 OUT OUT 3 2 1 USER INPUT 13 14 IN 8 ...

Page 8: ...OG OUTPUT HEATER CURRENT INPUT DEDICATED MAIN CONTROL O1 OUTPUT DEDICATED ALARM 1 A1 OUTPUT RS485 This output is programmable as either Control PID or as an Alarm This output is jumper and program selectable for either a current or voltage Linear DC output These part numbers are equipped with a second setpoint 1 Replacement Output Board RBD48100 may be used 2 Replacement Output Board RBD48111 may ...

Reviews: