Redlion CUB 5P Manual Download Page 12

Back

light 

Unit Only

Back

light Unit Only

Filter Band

Input R

ange 

Displa

y

Decimal P

oint 

Filter Setting

User Input Fu

nc

tion 

Input 

Value

for Scaling

Point 1 

 

User Input Assignment 

SEL

RST

Exit 

Pr

ogramming

SEL

RST

RST

RST

RST

RST

SEL

SEL

SEL

SEL

Display 

Value

for Scaling P

oint 1 

 

Input 

Value

for Scaling

Point 2 

 

Display 

Value

for Scaling P

oint 2 

 

Display 

Off

set

Value 

Scaling Style

Setpoin

t

Ac

tion 

 

Setpoin

t

Selec

Setpoin

t

Value 

Output Reset

Ac

tion 

Hy

steresis Value 

Off

 T

ime

Delay 

On 

Time

Delay 

Output Reset

W/Displa

y

Reset 

 

Change Displa

y

Color with

Output State 

 

SPSEL

4-SPt

Act-n

SPt-n

HYS-n

tON-n

tOF-n

rSt-n

rEn-n

ChC-n

Standb

y

Operation 

Stb-n

Fr

ont P

anel

Reset Enable 

Fr

ont P

anel

Displa

y

Selec

t Enable 

 

Displa

y

Update 

Time 

dSP-t

SEL

rSt

3-dSP

Displa

y

In

tensit

y

Le

vel 

 

COLOr

Units Indicato

r

Selec

tion 

UNItS

Displa

y

Co

lor 

d-LEV

Pr

ogramming

Security C

ode 

CodE

rANGE

dECPt

1-INP

FILtr

bANd

USrIN

INP 

1

dSP 

1

INP 

2

U-ASN

LO-En

M

in Displa

y

Enable 

Max Captur

e

Delay 

Time 

Max Displa

y

Enable 

HI-En

HI-t

2-SEC

M

in Captur

e

Delay 

Time 

LO-t

Fa

ct

or

y

Ser

vic

e

Operations 

 

FCS

Access Code F

or Ser

vic

e

Operations 

 

CodE

PAr

Pa

rity Bit

Baud 

Ra

te

bAUd

Data Bit

dAtA

5-SEr

Me

te

r

Address 

Addr

Abbreviate

d

Pr

inting 

Abbr

Pr

in

t

Options

OPt

  NO 

 

 Pro

 End

dSP 

2

OFSEt

StYLE

Ze

ro Displa

y

W/Displa

y

Reset 

 

ZErO

ScroL

Displa

y

Scr

oll

Enable 

 

cuB5p proGraMMinG QuicK overvieW

Press and hold 

SEL

 button to 

enter Programming Mode.

Summary of Contents for CUB 5P

Page 1: ...n be powered from an optional Red Lion Micro Line Sensor Power Supply MLPS which attaches directly to the back of a CUB5 The MLPS is powered from 85 to 250 VAC and provides up to 400 mA to drive the unit and sensors INPUT The CUB5P is a DC Process meter It features voltage and current input ranges that are selected by the user via a programming jumper and software input range selection The ranges ...

Page 2: ...FICATIONS AND COMPLIANCES CE Approved EN 61326 1 Immunity to Industrial Locations Emission CISPR 11 Class A Safety requirements for electrical equipment for measurement control and laboratory use EN 61010 1 General Requirements EN 61010 2 030 Particular Requirements for Testing and Measuring Circuits RoHS Compliant UL Recognized Component File E179259 UL Listed File E137808 Type 4X Indoor Outdoor ...

Page 3: ...85 SERIAL COMMUNICATIONS CARD Type RS485 multi point balanced interface non isolated Baud Rate 300 to 38 4k Data Format 7 8 bits odd even or no parity Bus Address 0 to 99 max 32 devices per line Transmit Delay Selectable refer to CUB5COM bulletin RS232 SERIAL COMMUNICATIONS CARD Type RS232 half duplex non isolated Baud Rate 300 to 38 4k Data Format 7 8 bits odd even or no parity USB PROGRAMMING CA...

Page 4: ...2010 1 07 Red Lion Controls LFIL0000 6 To protect relay contacts that control inductive loads and to minimize radiated and conducted noise EMI some type of contact protection network is normally installed across the load the contacts or both The most effective location is across the load a Using a snubber which is a resistor capacitor RC network or metal oxide varistor MOV across an AC inductive l...

Page 5: ...N U S A MLPS1 2 WIRE TRANSMITTER COMM INP _ MODEL INPUT POWER OUTPUT POWER 85 250 VAC 50 60Hz 14VA OPERATING TEMP 0 TO 60 C 12VDC UNREG 400mA 12V DC COMMON M3424B TERMINAL AC INPUT RED LION CONTROLS YORK PA MADE IN U S A MLPS1 2 WIRE TRANSMITTER INP COMM EXTERNAL POWER COMM COMM VDC VDC _ COMM INP MODEL INPUT POWER OUTPUT POWER 85 250 VAC 50 60Hz 14VA OPERATING TEMP 0 TO 60 C 12VDC UNREG 400mA 12V...

Page 6: ... pressing the SEL button with Pro NO displayed This will commit any stored parameter changes to memory and return the meter to the Display Mode If power loss occurs before returning to the Display Mode verify recent parameter changes PROGRAMMING TIPS It is recommended to start with Module 1 and proceed through each module in sequence When programming is complete it is recommended to record the par...

Page 7: ...ut Values have to be derived from the actual input signal source or simulator the Apply APLY scaling style must be used KEy APLY 0 000 INP 1 INPUT VALUE FOR SCALING POINT 1 For Key in KEY style enter the known first Input Value using the front panel buttons The Input Range selection sets the decimal location for the Input Value For Apply APLY style the meter shows the previously stored Input Value...

Page 8: ...ow FACTORY SERVICE OPERATIONS yES NO YES NO Enables the Maximum Display Capture capability Enables the Minimum Display Capture capability The CUB5P uses stored calibration values to provide accurate voltage and current measurements Over time the electrical characteristics of the components inside the meter could slowly change therefore the stored calibration values may no longer accurately define ...

Page 9: ...Backlight Unit Only 3 dSP dSP t SEL rSt ZErO UNItS COLOr CodE Display Intensity Level d LEV ScroL Display Scroll Enable PARAMETER MENU The yES selection allows the SEL button to toggle through the enabled displays FRONT PANEL DISPLAY SELECT ENABLE SEL This selection allows the RST button to reset the selected value s FRONT PANEL RESET ENABLE RST The yES selection allows the display to automaticall...

Page 10: ...nced are affected by the hysteresis When the setpoint is a control output usually balanced hysteresis is used For alarm applications usually unbalanced hysteresis is used For unbalanced hysteresis modes the hysteresis functions on the low side for high acting setpoints and functions on the high side for low acting setpoints Note Hysteresis eliminates output chatter at the switch point while time d...

Page 11: ...active when one of the optional serial communications programming cards is installed in the meter Refer to the CUB5COM bulletin for details and setup for the CUB5 RS232 or RS485 serial communications Refer to the CUB5USB bulletin for details on the CUB5 USB programming and programming requirements PARAMETER MENU button or user input manual reset serial reset command or meter power cycle When the u...

Page 12: ...n tOF n rSt n rEn n ChC n Standby Operation Stb n Front Panel Reset Enable Front Panel Display Select Enable Display Update Time dSP t SEL rSt 3 dSP Display Intensity Level COLOr Units Indicator Selection UNItS Display Color d LEV Programming Security Code CodE rANGE dECPt 1 INP FILtr bANd USrIN INP 1 dSP 1 INP 2 U ASN LO En Min Display Enable Max Capture Delay Time Max Display Enable HI En HI t 2...

Reviews: