Redlion CUB 5P Manual Download Page 11

11

LIMITED WARRANTY

(a) Red Lion Controls Inc. (the “Company”) warrants that all Products shall be free from defects in material and workmanship under normal 

use for the period of time provided in “Statement of Warranty Periods” (available at 

www.redlion.net

current at the time of shipment 

of  the  Products  (the  “Warranty  Period”). 

EXCEPT FOR THE ABOVE-STATED WARRANTY, COMPANY MAKES NO WARRANTY 

WHATSOEVER WITH RESPECT TO THE PRODUCTS, INCLUDING ANY (A) WARRANTY OF MERCHANTABILITY; (B) WARRANTY 

OF FITNESS FOR A PARTICULAR PURPOSE; OR (C) WARRANTY AGAINST INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS 

OF A THIRD PARTY; WHETHER EXPRESS OR IMPLIED BY LAW, COURSE OF DEALING, COURSE OF PERFORMANCE, USAGE OF 

TRADE OR OTHERWISE.

 Customer shall be responsible for determining that a Product is suitable for Customer’s use and that such use 

complies with any applicable local, state or federal law. 

(b) The Company shall not be liable for a breach of the warranty set forth in paragraph (a) if (i) the defect is a result of Customer’s failure 

to store, install, commission or maintain the Product according to specifications; (ii) Customer alters or repairs such Product without the 

prior written consent of Company.

(c) Subject to paragraph (b), with respect to any such Product during the Warranty Period, Company shall, in its sole discretion, either 

(i) repair or replace the Product; or (ii) credit or refund the price of Product provided that, if Company so requests, Customer shall, at 

Company’s expense, return such Product to Company.

(d) 

THE REMEDIES SET FORTH IN PARAGRAPH (c) SHALL BE THE CUSTOMER’S SOLE AND EXCLUSIVE REMEDY AND COMPANY’S 

ENTIRE LIABILITY FOR ANY BREACH OF THE LIMITED WARRANTY SET FORTH IN PARAGRAPH (a)

BY INSTALLING THIS PRODUCT, YOU AGREE TO THE TERMS OF THIS WARRANTY, AS WELL AS ALL OTHER DISCLAIMERS AND 

WARRANTIES IN THIS DOCUMENT.

6.5  Module 5 - S

erial

 S

etup

 p

araMeterS

 (

5-SEr

)

SEL

Data Bit

Baud Rate

Parity Bit

Print 

Options

Meter 

Address

Abbreviated 

Printing

5-SEr

bAUd

dAtA

PAr

Addr

Abbr

OPt

Pro

The Serial Setup Parameters are only active when one of the optional serial communications/programming cards is installed in the meter. 

Refer to the CUB5COM bulletin for details and setup for the CUB5 RS232 or RS485 serial communications.

Refer to the CUB5USB bulletin for details on the CUB5 USB programming and programming requirements.

PARAMETER MENU

button or user input manual reset, serial reset command or meter power cycle. 

When the user input or 

RST

 button is activated (momentary action), the 

corresponding “on” output is reset immediately and remains off until the 

trigger point is crossed again. (Previously latched alarms will be off if power 

up Display Value is lower than setpoint value.)

L-dLY

 = Latch with delay reset action; This action latches the output on at the 

trigger point per the Setpoint Action shown in Setpoint Output Figures. Latch 

means that the output can only be turned off by the front panel 

RST

 button 

or user input manual reset, serial reset command or meter power cycle. When 

the user input or 

RST

 button is activated (momentary action), the meter 

delays the event until the corresponding “on” output crosses the trigger off 

point. (Previously latched outputs are off if power up Display Value is lower 

than setpoint value. During a power cycle, the meter erases a previous 

L-dLY

 

reset if it is not activated at power up.)

OUTPUT

STATE

OFF

ON

Hys

SP

Auto

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

MANUAL

RESET

LAtCH

L-dLY

SP - Hys

(       )

(         )

(         )

{

Setpoint Output Reset Actions

This parameter enables the 

RST

 button or user input to reset the output when 

the display is reset.

Note: For this parameter to operate, the 

RST

 button or User Input being used 

must be set to 

dSP

 and the Input value must be displayed. If these conditions are 

not met, the output will not reset.

YES

rEn-n

OUTPUT RESET WITH DISPLAY RESET

YES

NO

When 

YES

, the output is disabled (after a power up) until the  trigger point is 

crossed. Once the output is on, the output operates normally per the Setpoint 

Action and Output Reset action.

NO

Stb-n

STANDBY OPERATION

YES

NO

This parameter enables the backlight CUB5 to switch the backlight color when 

the output state changes. This parameter is only active for the backlight version.

CHANGE DISPLAY COLOR w/OUTPUT STATE

NO

ChC-n

YES

NO

Summary of Contents for CUB 5P

Page 1: ...n be powered from an optional Red Lion Micro Line Sensor Power Supply MLPS which attaches directly to the back of a CUB5 The MLPS is powered from 85 to 250 VAC and provides up to 400 mA to drive the unit and sensors INPUT The CUB5P is a DC Process meter It features voltage and current input ranges that are selected by the user via a programming jumper and software input range selection The ranges ...

Page 2: ...FICATIONS AND COMPLIANCES CE Approved EN 61326 1 Immunity to Industrial Locations Emission CISPR 11 Class A Safety requirements for electrical equipment for measurement control and laboratory use EN 61010 1 General Requirements EN 61010 2 030 Particular Requirements for Testing and Measuring Circuits RoHS Compliant UL Recognized Component File E179259 UL Listed File E137808 Type 4X Indoor Outdoor ...

Page 3: ...85 SERIAL COMMUNICATIONS CARD Type RS485 multi point balanced interface non isolated Baud Rate 300 to 38 4k Data Format 7 8 bits odd even or no parity Bus Address 0 to 99 max 32 devices per line Transmit Delay Selectable refer to CUB5COM bulletin RS232 SERIAL COMMUNICATIONS CARD Type RS232 half duplex non isolated Baud Rate 300 to 38 4k Data Format 7 8 bits odd even or no parity USB PROGRAMMING CA...

Page 4: ...2010 1 07 Red Lion Controls LFIL0000 6 To protect relay contacts that control inductive loads and to minimize radiated and conducted noise EMI some type of contact protection network is normally installed across the load the contacts or both The most effective location is across the load a Using a snubber which is a resistor capacitor RC network or metal oxide varistor MOV across an AC inductive l...

Page 5: ...N U S A MLPS1 2 WIRE TRANSMITTER COMM INP _ MODEL INPUT POWER OUTPUT POWER 85 250 VAC 50 60Hz 14VA OPERATING TEMP 0 TO 60 C 12VDC UNREG 400mA 12V DC COMMON M3424B TERMINAL AC INPUT RED LION CONTROLS YORK PA MADE IN U S A MLPS1 2 WIRE TRANSMITTER INP COMM EXTERNAL POWER COMM COMM VDC VDC _ COMM INP MODEL INPUT POWER OUTPUT POWER 85 250 VAC 50 60Hz 14VA OPERATING TEMP 0 TO 60 C 12VDC UNREG 400mA 12V...

Page 6: ... pressing the SEL button with Pro NO displayed This will commit any stored parameter changes to memory and return the meter to the Display Mode If power loss occurs before returning to the Display Mode verify recent parameter changes PROGRAMMING TIPS It is recommended to start with Module 1 and proceed through each module in sequence When programming is complete it is recommended to record the par...

Page 7: ...ut Values have to be derived from the actual input signal source or simulator the Apply APLY scaling style must be used KEy APLY 0 000 INP 1 INPUT VALUE FOR SCALING POINT 1 For Key in KEY style enter the known first Input Value using the front panel buttons The Input Range selection sets the decimal location for the Input Value For Apply APLY style the meter shows the previously stored Input Value...

Page 8: ...ow FACTORY SERVICE OPERATIONS yES NO YES NO Enables the Maximum Display Capture capability Enables the Minimum Display Capture capability The CUB5P uses stored calibration values to provide accurate voltage and current measurements Over time the electrical characteristics of the components inside the meter could slowly change therefore the stored calibration values may no longer accurately define ...

Page 9: ...Backlight Unit Only 3 dSP dSP t SEL rSt ZErO UNItS COLOr CodE Display Intensity Level d LEV ScroL Display Scroll Enable PARAMETER MENU The yES selection allows the SEL button to toggle through the enabled displays FRONT PANEL DISPLAY SELECT ENABLE SEL This selection allows the RST button to reset the selected value s FRONT PANEL RESET ENABLE RST The yES selection allows the display to automaticall...

Page 10: ...nced are affected by the hysteresis When the setpoint is a control output usually balanced hysteresis is used For alarm applications usually unbalanced hysteresis is used For unbalanced hysteresis modes the hysteresis functions on the low side for high acting setpoints and functions on the high side for low acting setpoints Note Hysteresis eliminates output chatter at the switch point while time d...

Page 11: ...active when one of the optional serial communications programming cards is installed in the meter Refer to the CUB5COM bulletin for details and setup for the CUB5 RS232 or RS485 serial communications Refer to the CUB5USB bulletin for details on the CUB5 USB programming and programming requirements PARAMETER MENU button or user input manual reset serial reset command or meter power cycle When the u...

Page 12: ...n tOF n rSt n rEn n ChC n Standby Operation Stb n Front Panel Reset Enable Front Panel Display Select Enable Display Update Time dSP t SEL rSt 3 dSP Display Intensity Level COLOr Units Indicator Selection UNItS Display Color d LEV Programming Security Code CodE rANGE dECPt 1 INP FILtr bANd USrIN INP 1 dSP 1 INP 2 U ASN LO En Min Display Enable Max Capture Delay Time Max Display Enable HI En HI t 2...