5.3.1 boardConfig - Board Setup Commands
The boardConfig mode allows you to view and modify the subscriber board level
settings. The following table lists all commands available in this mode.
Table 11: CLI - boardConfig - Board Commands
Command
Description
reset
Set all parameters to factory default values. Confirmation required.
set
Change parameter settings.
RefOscFreq
: Enter an unsigned integer as the new RefOscFreq value
(Hz). Value can be only 32000000 or 40000000.
TxIfFreq
: Enter the TxIfFreq (Hz) value (around 44000000).
RxIfFreq
: Enter the RxIfFreq (Hz) value (around 44000000).
RfType
: Enter an unsigned char as the new RfType value. One of:
0 - None
1 - Radia 3.5 GHz
2 - Radia 5.8 GHz
3 - SMI
4 - Factory Test
IfPresent
: Enter an unsigned char as the new IfPresent value.
0 - Baseband only
1 - IF present
TxSpectrumInv
: Enter a boolean as the new TxSpectrumInv value.
RxSpectrumInv
: Enter a boolean as the new RxSpectrumInv value.
Buzzer
: Antenna positioning buzzer.
0 - Disabled
1 - Enabled.
DebugLog
: Factory debug messages.
0 - Disabled.
1- Enabled.
show
Display the current setting for all parameters. For example:
Structure --- <<SS Mmgt Board Configuration Parameter>>
Transmit
Receive
Others
------------------------------ ------------------------------
----------------
IfFreq: 44000000Hz
IfFreq:
44000000Hz
RefOscFreq:
32000000Hz
SpectrumInv: disabled(0)
SpectrumInv: disabled(0)
RfType:
SMI(3)
IfPresent:
IF_Present(1)
Buzzer:
disabled(0)
DebugLog: