Mega
Plus
®
Model ES 4.0/E
TYPE
IN
RESPONSE
RDM=2
BNS=3
RDM=2
BNS=2
RDM=2
BNS=1
RDM=1
BNS=3
RDM=1
BNS=2
RDM=1
BNS=1
FRS 60
CR-LF 60
fps/
20 MHz
** ** ** ** **
FRS 30
CR-LF 30
fps/
20 MHz
30 fps/
20 MHz
** 30
fps/
20 MHz
** **
FRS 15
CR-LF 15
fps/
10 MHz
15 fps/
20 MHz
15 fps/
40 MHz
15 fps/
20 MHz
15 fps/
20 MHz
**
FRS 8
CR-LF ** 8
fps/
10 MHz
8 fps/
20 MHz
** 8
fps/
20 MHz
8 fps/
40 MHz
FRS 4
CR-LF ** ** 4
fps/
10 MHz
** ** 4
fps/
20 MHz
3.4.11 Exposure
This command sets the camera exposure time in increments of 0.063 milliseconds. In continuous
mode, the camera accepts exposure values from .091 to 64.957 milliseconds when BNS is set
to 1; and values between .092 and 32.451 milliseconds when BNS is set to 2. If the camera is
operating in triggered mode, the maximum exposure time becomes 112.298 milliseconds.
NOTE
: The camera accepts and remembers a different exposure time for each of the three
binning modes. The camera switches to the stored exposure time when switching
binning modes.
TYPE IN:
RESPONSE
EXPLANATION
EXE xxxx
CR-LF
The argument range is from .091 to 112 to 298
milliseconds in increments of .063 milliseconds,
depending on the operating mode, the camera will
round up to the next valid setting for any exposure
value entered.
EXE?
Queries the current exposure setting. The value
returned is the corrected value in milliseconds.
EXE xxxx
Means the exposure is set, expressed in
milliseconds.
NOTE
: After EXExxxx or EXE? Has been executed, type in “+” to increase the exposure time or
type in “-“ to decrease the exposure time by 0.063 milliseconds. The camera will respond
with the new value.
3.4.12 Trigger
This command selects the trigger source and polarity. There is two trigger inputs: the SMA
connector on the rear panel of the camera (labeled TRIGGER), and the EXPOSE input carried by
the digital interface connector. The camera will only respond to the selected source.
TYPE IN:
RESPONSE
EXPLANATION
TRS AIA
CR-LF
Selects the digital interface connector EXPOSE
signal as the trigger source.
TRS EXT
CR-LF
Selects the TRIGGER connector on the rear panel
as the trigger source.
TRS SW
CR-LF
Selects the TRE software commands as the trigger
source.
TRS?
Queries the trigger source.
91000116-001 Revision B
3-5
USER’S MANUAL
Summary of Contents for MegaPlus ES 4.0/E
Page 6: ...REDLAKE MASD INC THIS PAGE INTENTIONALLY LEFT BLANK 91000116 001 Revision B vi 10 15 02 ...
Page 14: ...REDLAKE MASD INC THIS PAGE INTENTIONALLY LEFT BLANK 91000116 001 Revision B 2 6 10 15 02 ...
Page 38: ...REDLAKE MASD INC THIS PAGE INTENTIONALLY LEFT BLANK 91000116 001 Revision B 4 12 10 15 02 ...
Page 40: ...REDLAKE MASD INC THIS PAGE INTENTIONALLY LEFT BLANK 91000116 001 Revision B II 10 15 02 ...