CONDITION 

CAUSE 

REMEDY / ACTION 

button has been pressed. 

OTHE

R

 

Smoke alarm will not slide 
along the base until it 
clicks. 

Battery or batteries missing 

Install missing battery or batteries  

False Alarm 

In the event of a false alarm (alarms are sounding without any smoke present):  
1.

 

Identify which smoke alarm/s are in alarm state – Look for the alarm/s sounding and with red LED fast flashing. 

2.

 

On each smoke alarm in alarm state press the Test+Hush button to silence the alarm 

3.

 

Disconnect all smoke alarms in the alarm state by removing them from their base.  

4.

 

Clean smoke alarms in accordance with the “Maintenance, Repairs and Service” section.  

5.

 

Re-install and test all the smoke alarms.  

IMPORTANT: If the above process fails, contact a licenced electrician to investigate. 

Maintenance, Repairs and Service 

It is recommended that the smoke alarm is inspected monthly to ensure it is free from dirt, dust and insects. The 
alarm can be vacuumed or brushed with a soft brush to remove dust, dirt or kitchen grease that has accumulated.  
 

ALWAYS TEST THE SMOKE ALARM AFTER CLEANING.  
 

If the smoke alarm is defective in any way, do not tamper with the smoke alarm. The smoke alarm does not contain 
any user-serviceable parts.  As the smoke alarm does not contain any radioactive material, disposal with domestic 
rubbish is permitted in Australia and New Zealand. 

Warranty 

Redbusbar Pty Ltd, warrants this product to be free from defects in materials and workmanship for a period of 5 
(five) years from the date of installation. Refer to the Redbusbar terms of sale for full warranty conditions 

http://www.redbusbar.com/Terms-and-Conditions.html

 

 
Redbusbar reserves the right to change specifications, modify designs and discontinue items without incurring 
obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this 
document are correct, no warranty is given in respect thereof and the company shall not be liable for any error 
therein. © Redbusbar 2018. Redbusbar acknowledges that the Activfire Certified logo is a trademark of CSIRO. 
 

 

 

 

 

 

Summary of Contents for SS10LNAN

Page 1: ...ries Refer to Replacing the Backup Batteries EQUIPMENT INSTALLATION HAZARD This product must only be used for the purpose described in these instructions and must be installed in accordance with the l...

Page 2: ...cation Status Alert Escape White LED Audible Indication Alert 50dBA at 3m Battery Low Chirp Locations This smoke alarm can be used in all residential homes and apartments and positioned in accordance...

Page 3: ...g base by twisting it back and forth until it breaks loose 2 Screw the mounting base onto the ceiling or wall using appropriate fasteners Screw diameter 8gauge 4mm 3 If the Radio Interlink feature is...

Page 4: ...us configuration modes the option card functions can be configured Option card status requests and configuration commands are made using sequential quick taps on the Test Hush button Responses from th...

Page 5: ...witch ON 3 Spare 4 Return to Operation Mode 5 5 Return to Factory Defaults Radio Interlink Configuration Mode Command Taps Description Response White LED Flashes Beeps 0 Radio Interlink Configuration...

Page 6: ...hes Beeps Perform a Return to Factory Defaults on the lost slave alarm s 2 White LED Flashes Beeps and remove their option card batteries Then re add them to the network using the Add Radio Node proce...

Page 7: ...this procedure if your network is not functioning correctly and it is not convenient to perform individual Return to Factory Defaults on each smoke alarm eg the smoke alarms are mounted on a high ceil...

Page 8: ...rm and each subsequent alarm on your network taking care to only apply power to each alarm following confirmation that the previously powered alarm has joined the network as a slave 4 Once all alarms...

Page 9: ...tory default test settings are every two weeks from the day and time that the option card is first supplied with power Continue with the following steps only if you wish to change Auto Test times 2 Se...

Page 10: ...ert small children in the home 2 Leave immediately by your plan of escape Don t waste time getting dressed or picking up valuables 3 When leaving don t open any inside door without first feeling its s...

Page 11: ...ity is too high even in low sensitivity mode for the Hush feature to activate Smoke alarm is sounding it stops when Test Hush is pressed Low sensitivity mode has been activated for 9mins Make sure you...

Page 12: ...arm can be vacuumed or brushed with a soft brush to remove dust dirt or kitchen grease that has accumulated ALWAYS TEST THE SMOKE ALARM AFTER CLEANING If the smoke alarm is defective in any way do not...

Reviews: