Redback® Proudly Made In Australia
9
Redback®
Programmable Control System
System Configurations
3.3 TWO RELAY SETUP (HIGH CURRENT, NO SERIAL or IR)
The high power setup provides up to two output relays for switching, with no serial or IR outputs. The relays are high current
outputs rated at 16A maximum and a set of normally open and normally closed contacts are available for each relay.
The A 6500 Wall Plate is connected to the A 6515 via a CAT5e/6 cable. 24V DC power is connected to the A 6505 by a
plugpack with a 2.1mm jack or through the euro block terminals. The A 6515 in turn powers the A 6500 Wall Plate through
the Cat5e/6 cable.
Fig 3.3
3.4 THIRD PARTY RELAY CONTROL
The A 6510 and A 6515 relay distribution boxes can both be controlled by a third party device with either an RS232 or RS485
output, via serial commands which are described in the supplied programming manual.
NOTE: The A 6510 and A 6515 will receive serial only. They do not transmit any serial data.
See section 4.0 for serial wiring details.
Fig 3.4
Redback® A 6500
Redback® A 6515
24V DC PLUGPACK
(MINIMUM 1A)
(Cat5/6 Cable 50m Maximum)
RELAY CONTROLLED DEVICES
(CONTACTS MAX 16A)
Relay OUT
RS485
RS232
TO A 6500
TO REDBACK
®
DEVICES
2 1
24V DC PLUGPACK
(MINIMUM 1A)
RS232/
RS485
RS232/
RS485
RELAY CONTROLLED DEVICES
(CONTACTS MAX 16A)
Relay OUT
RS485
RS232
TO A 6500
TO REDBACK
®
DEVICES
2 1
Redback® A 6515
Redback® A 6510
Relay OUT
RS485
RS232
1
2
3
4
5
6
7
8
9
10
11
12
TO A 6500
TO REDBACK
®
DEVICES
RELAY CONTROLLED DEVICES
(CONTACTS MAX 1A)
SERIAL OUT
SERIAL OUT
Third Party Device